Predicting the Clinical Advantages of Speaking Valves Through Wearable Devices
1 other identifier
interventional
120
1 country
1
Brief Summary
The population included in this study consists of tracheostomy patients admitted to the pulmonary department of Beijing Rehabilitation Hospital, undergoing decannulation rehabilitation treatment. Once patient conditions stabilized, they were all transitioned to the decannulation process established by our department in 2018, which utilizes a speaking valve instead of capping.The initial duration for the patient to wear the speaking valve is 30 minutes.The monitoring period for wearable devices is from 1 hour before the initial use of the speaking valve to 1 hour after its removal.Monitored for a total of 2 hours and 30 minutes.Explore the clinical benefits of the speaking valve by comparing the changes in patients' physiological parameters and clinical index metrics before and after using the speaking valve. Criteria for the successful use of the speaking valve for 30 minutes:
- 1.Breathing is steady at rest: no apparent dyspnea, chest tightness, or orthopnea, etc.
- 2.Heart rate, blood pressure, and SpO₂ are all stable overall.SpO₂ reduction from baseline \< 5%.
- 3.No frequent need for emergency sputum suction or indications of sputum blockage while wearing it.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Apr 2026
Shorter than P25 for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 27, 2026
CompletedStudy Start
First participant enrolled
April 16, 2026
CompletedFirst Posted
Study publicly available on registry
May 14, 2026
CompletedPrimary Completion
Last participant's last visit for primary outcome
June 1, 2026
ExpectedStudy Completion
Last participant's last visit for all outcomes
December 31, 2026
May 14, 2026
April 1, 2026
2 months
February 27, 2026
May 11, 2026
Conditions
Keywords
Outcome Measures
Primary Outcomes (3)
degree of change in oxygen saturation(%)
Previous studies have been concerned that speaking valve placement increases upper airway resistance, thereby inducing dyspnea and hypoxemia in patients. Therefore, we used continuous wearable physiological monitoring devices to observe changes in oxygen saturation before, during, and after the training.
Using wearable biosensors, high-resolution physiological data were continuously collected during three phases: baseline (30 minutes), speaking valve placement period (30 minutes), and recovery period (30 minutes after speaking valve removal).
Temporal rate of change of asymmetric cardiovascular responses and delayed autonomic recovery(percentage change from baseline)
The rate of change (percentage per minute) in asymmetric cardiovascular responses (e.g., heart rate variability indices) and delayed autonomic recovery will be calculated. Physiological data (heart rate, HRV metrics) are continuously collected before, during, and after speaking valve placement. The primary reported value is the slope of change over time, expressed as a percentage relative to baseline, aggregated across all participants using mixed-effects modeling to produce a single mean rate of change
30 minutes before speaking valve placement, throughout the entire training session (i.e., during valve wear), and 30 minutes after the training session
Rate of respiratory phase variation during training(percentage change in phase duration)
The rate of change in respiratory phase variation (e.g., changes in inspiratory/expiratory time proportion) during speaking valve training. Respiratory parameters are continuously recorded. The outcome is the calculated rate of change (percentage per minute) from baseline to the active training period and to the recovery period. A single aggregated value (mean slope) will be derived from all participants using linear mixed models.
30 minutes before speaking valve placement, throughout the entire training session (i.e., during valve wear), and 30 minutes after the training session
Study Arms (1)
Successfully wore the speaking valve for the first time for 30 minutes.
EXPERIMENTALInclusion Criteria: 1. Breathing is steady at rest: no apparent dyspnea, chest tightness, or orthopnea, etc. 2. Heart rate, blood pressure, and SpO₂ are all stable overall.SpO₂ reduction from baseline \< 5%. 3. No frequent need for emergency sputum suction or indications of sputum blockage while wearing it.
Interventions
Once patient conditions stabilized, they were all transitioned to the decannulation process established by our department in 2018, which utilizes a speaking valve instead of capping.The initial duration for the patient to wear the speaking valve is 30 minutes.If the patient can tolerate wearing the speaking valve for 30 minutes, they fulfill the inclusion criteria.The monitoring period for wearable devices is from 1 hour before the initial use of the speaking valve to 1 hour after its removal.Monitored for a total of 2 hours and 30 minutes. Physiological parameters recorded prior to wearing the speaking valve served as the baseline.Compare the physiological parameters while wearing the speaking valve and after its removal to investigate the clinical benefits that the speaking valve can provide.To promote the application of speaking valves in future clinical work more effectively
Eligibility Criteria
You may qualify if:
- years≥Age≥18 years;
- Tracheotomy post-operation\>48 hours;
- Weaned off mechanical ventilation;
- Clinically stable condition;
- Tolerable for cuff deflation;
- Able to tolerate wearing a speaking valve continuously for 30 minutes;
- Signed informed consent.
You may not qualify if:
- Patients with abnormal skin conditions preventing continuous wearing of monitoring devices;
- Inability to tolerate wearing a speaking valve continuously for 30 minutes;
- Interruption of physiological monitoring data;
- Poor quality of physiological monitoring data;
- Recently underwent neck/upper airway surgery (≤48 hours, to avoid airflow impact on the upper airway);
- Severe consciousness disturbance/delirium (RASS score≤-3 or ≥ +2), extreme anxiety/uncooperativeness;
- Total laryngectomy or laryngotracheal separation;
- Age \<18 years or \>90 years;
- Malignant tumor with an expected survival time ≤6 months;
- The patient or legal representative is unable to sign the informed consent form.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Bin Zhanglead
- Capital Medical Universitycollaborator
- Chinese PLA General Hospitalcollaborator
Study Sites (1)
Beijing Rehabilitation Hospital, Capital Medical University
Beijing, Beijing Municipality, 100144, China
Study Officials
- STUDY CHAIR
Hongying Jiang
Beijing Rehabilitation Hospital of Capital Medical University, Beijing, China
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- OTHER
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR INVESTIGATOR
- PI Title
- Principal Investigator
Study Record Dates
First Submitted
February 27, 2026
First Posted
May 14, 2026
Study Start
April 16, 2026
Primary Completion (Estimated)
June 1, 2026
Study Completion (Estimated)
December 31, 2026
Last Updated
May 14, 2026
Record last verified: 2026-04
Data Sharing
- IPD Sharing
- Will not share