Study Stopped
Device was sunset from the market in May2015. No longer need for long term data.
Enable I Long-term Follow-up Study
1 other identifier
observational
42
3 countries
6
Brief Summary
This was a prospective, non-randomized, multi-center, non-interventional post-market study. The study was a post-market long-term follow-up study based on the same cohort of patients (148 patients) enrolled in a previous investigational study from March 2007 to December 2009 (ATS 3f Enable™ Aortic Bioprosthesis Model 6000, number S2005) involving 10 European sites. Patient follow-up took place on a yearly basis up to 10 years after the implant/enrollment. The primary objective of this study was to evaluate the safety and effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis during long-term follow-up. As this was an observational study, safety and efficacy data were summarized and described. There was no statistically powered study hypothesis.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Aug 2012
Typical duration for all trials
6 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
July 6, 2012
CompletedFirst Posted
Study publicly available on registry
July 10, 2012
CompletedStudy Start
First participant enrolled
August 1, 2012
CompletedPrimary Completion
Last participant's last visit for primary outcome
April 1, 2016
CompletedStudy Completion
Last participant's last visit for all outcomes
April 1, 2016
CompletedNovember 21, 2017
November 1, 2017
3.7 years
July 6, 2012
November 17, 2017
Conditions
Keywords
Outcome Measures
Primary Outcomes (3)
Assess the Long-term safety of the Medtronic ATS Enable Aortic Bioprosthesis
Long-term safety will be assessed by collecting following reported adverse events addressed: Migration, Valve Related Thromboembolism, Valvular thrombosis, Haemorrhage, Perivalvular Leak, Endocarditis, Hmolysis, Structural valve Deterioration, Non-Structural Dysfunction, Reoperation, Explant and Death.
10 Years Post-Procedure
Assess the Long-term Clinical Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: NYHA Functional Classification
Long-term clinical effectiveness of the Aortic Bioprosthesis will be assessed by collecting the NYHA-class of enrolled subjects over a period of time, following surgery.
10 Years Post-Procedure
Long-term Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: Hemodynamic Performance
Hemodynamic performance of the Aortic Bioprosthesis will be assessed by specific echocardiography measurements
10 Years Post-Procedure
Interventions
Aortic Valve Replacement with Medtronic ATS 3f ENABLE® Aortic Bioprosthesis Model 6000
Eligibility Criteria
Patients who were enrolled and implanted during the previous investigational study named "ATS 3f Enable™ Aortic Bioprosthesis Model 6000" (study number S2005).
You may qualify if:
- Patients who were enrolled and implanted for the ATS 3f Enable™ Aortic Bioprosthesis Model 6000, number S2005
- Patient willing to sign the new Data Release form (DRF) or Patient Informed Consent (PIC) for the post-market study (what is applicable for the study due to local requirements and regulations)
You may not qualify if:
- ATS 3f Enable™ Aortic Bioprosthesis Model 6000 was explanted
- Patient died
- Patient lost to follow-up
- Patient withdrew consent
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (6)
Johann Wolfgang Goethe University
Frankfurt, D-60590, Germany
University Medical Center Freiburg
Freiburg im Breisgau, 79106, Germany
University Medical Center Kiel
Kiel, 24105, Germany
Jagellonian University, John Paul the II Hospital
Krakow, 31-202, Poland
Universitätsspital Basel
Basel, CH-4031, Switzerland
Inselspital Bern
Bern, CH-3010, Switzerland
Related Publications (2)
Martens S, Sadowski J, Eckstein FS, Bartus K, Kapelak B, Sievers HH, Schlensak C, Carrel T. Clinical experience with the ATS 3f Enable(R) Sutureless Bioprosthesis. Eur J Cardiothorac Surg. 2011 Sep;40(3):749-55. doi: 10.1016/j.ejcts.2010.12.068. Epub 2011 Feb 20.
PMID: 21342776BACKGROUNDEnglberger L, Carrel TP, Doss M, Sadowski J, Bartus K, Eckstein FF, Asch FM, Martens S. Clinical performance of a sutureless aortic bioprosthesis: five-year results of the 3f Enable long-term follow-up study. J Thorac Cardiovasc Surg. 2014 Oct;148(4):1681-7. doi: 10.1016/j.jtcvs.2014.03.054. Epub 2014 Apr 4.
PMID: 24787699BACKGROUND
MeSH Terms
Conditions
Interventions
Condition Hierarchy (Ancestors)
Intervention Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Thierry Carrel, Prof.
Inselspital Bern, Klinik für Herz-und Gefasschirurgie, CH-3010 Bern
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
July 6, 2012
First Posted
July 10, 2012
Study Start
August 1, 2012
Primary Completion
April 1, 2016
Study Completion
April 1, 2016
Last Updated
November 21, 2017
Record last verified: 2017-11
Data Sharing
- IPD Sharing
- Will not share