Brief Summary

The purpose of this study is to evaluate the safety and effectiveness of the Bausch \& Lomb Technolas 217z laser with the investigational Zyoptix Aspheric Algorithm when used for LASIK treatment of myopia and myopic astigmatism.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
72

participants targeted

Target at P50-P75 for not_applicable

Timeline
Completed

Started Aug 2008

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

August 1, 2008

Completed
2 months until next milestone

First Submitted

Initial submission to the registry

October 8, 2008

Completed
1 day until next milestone

First Posted

Study publicly available on registry

October 9, 2008

Completed
1.4 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

March 1, 2010

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

March 1, 2010

Completed
10.5 years until next milestone

Results Posted

Study results publicly available

September 11, 2020

Completed
Last Updated

September 11, 2020

Status Verified

August 1, 2020

Enrollment Period

1.6 years

First QC Date

October 8, 2008

Results QC Date

May 9, 2017

Last Update Submit

August 24, 2020

Conditions

Outcome Measures

Primary Outcomes (6)

  • Percentage of Eyes With Uncorrected High Contrast Distance Visual Acuity of 20/40 or Better

    3 months

  • Percentage of Eyes With Manifest Subjective Refraction (MRSE) Within ± 1.00 Diopter (D) and 0.50 D of Emmetropia

    Manifest refractions (eyeglass prescriptions) have three components: sphere, cylinder, and axis. Sphere and cylinder are both expressed in diopters, which is a continuous measure of the focusing power needed to make the image sharp on the retina. Manifest refraction spherical equivalent (MRSE) is equal to sphere + ½ x cylinder. It is expressed in diopters (D).

    3 months

  • Preservation of Manifest Best Corrected High Contrast Distance Visual Acuity

    Mean change in best-corrected high contrast distance visual acuity. Corrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity. Acuity was averaged across visits.

    Baseline, 3 months

  • Percentage of Eyes With Manifest Best-corrected Distance Photopic Visual Acuity Decrease of 2 or More Lines

    3 months

  • Percentage of Eyes With > 2.00 Diopter of Induced Postoperative Refractive Cylinder

    Manifest refractions (eyeglass prescriptions) have three components: sphere, cylinder, and axis. Sphere and cylinder are both expressed in diopters, which is a continuous measure of the focusing power needed to make the image sharp on the retina. Manifest refraction spherical equivalent (MRSE) is equal to sphere + ½ x cylinder. It is expressed in diopters (D).

    3 months

  • Percentage of Eyes That Had High Contrast Best Spectacle Corrected Visual Acuity (HCBSCVA) of 20/20 or Better at Baseline Had a Visual Outcome Worse Than 20/40 at 3 Months

    Corrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity. Acuity was averaged across visits.

    3 months

Secondary Outcomes (1)

  • Percentage Change From Baseline in Higher Order Aberrations.

    Baseline, 3 months

Study Arms (1)

Technolas 217z Excimer Laser

EXPERIMENTAL

Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.

Device: Bausch & Lomb 217z Excimer Laser

Interventions

LASIK correction of myopia and myopic astigmatism

Technolas 217z Excimer Laser

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • Subjects who were of legal age (at least 18) and had full legal capacity to volunteer.
  • Subjects must be willing to have both eyes treated with the laser.
  • Subjects must have up to -12.00D of absolute spherical myopia (not spherical equivalent) with up to -6.00D of refractive astigmatism, with a spherical equivalent up to -15.00D as measured by manifest subjective refraction.
  • Subjects who had less than 0.75 D of difference in the preoperative manifest spherical equivalent and cycloplegic spherical equivalent subjective refractions.
  • (Manifest subjective refractions adjusted for optical infinity were used.)
  • High contrast, manifest best spectacle-corrected distance logMAR visual acuity correctable to at least 0.3 in both eyes, and must not differ between eyes by more than 1 line (5 letters).
  • Contact lens wearers must have 2 Orbscan measurements and 2 manifest subjective refractions taken preoperatively at least 1 week apart.
  • Contact lens wearers must have gas permeable lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 2 weeks prior to the preoperative evaluation.

You may not qualify if:

  • Subjects with uncorrected visual acuity better than 20/40 (Snellen) or 0.3 logMAR
  • Subjects who were immuno-compromised or had a diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that increased the risk to the subject or could have confounded the outcomes of this study.
  • Subjects with uncontrolled glaucoma or glaucoma who were under treatment in the study eye or with ocular hypertension.
  • Subjects who demonstrated evidence of retinal vascular disease.
  • Subjects who have an ocular muscle disorder including strabismus or nystagmus, or other disorders that affected fixation.
  • Subjects who were at risk for angle closure or who had a potentially occludable angle, as evidenced by a shallow anterior chamber on slit lamp exam, confirmed by gonioscopy as deemed necessary by the study Investigator.
  • Subjects who had undergone previous intraocular or corneal surgery of any kind, including any type of excimer laser surgery for either refractive or therapeutic purposes.
  • Subjects who were taking systemic medications likely to affect wound healing such as corticosteroids or anti-metabolites or any other medications that may increase the risk to the subject or confound the outcomes of this study.
  • Subjects for whom the combination of their preoperative corneal thickness and the planned operative parameters for the LASIK procedure could have resulted in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Lasik MD, 130 King Street

Toronto, Ontario, M5X1C8, Canada

Location

MeSH Terms

Conditions

MyopiaAstigmatism

Condition Hierarchy (Ancestors)

Refractive ErrorsEye Diseases

Results Point of Contact

Title
Study Director
Organization
Bausch & Lomb Incorporated

Study Officials

  • Mark Cohen, MD

    Lasik MD

    PRINCIPAL INVESTIGATOR

Publication Agreements

PI is Sponsor Employee
No
Restriction Type
OTHER
Restrictive Agreement
Yes

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NA
Masking
NONE
Purpose
TREATMENT
Intervention Model
SINGLE GROUP
Model Details: This was a medical device study with only one intervention used for lasik correction surgery
Sponsor Type
INDUSTRY
Responsible Party
SPONSOR

Study Record Dates

First Submitted

October 8, 2008

First Posted

October 9, 2008

Study Start

August 1, 2008

Primary Completion

March 1, 2010

Study Completion

March 1, 2010

Last Updated

September 11, 2020

Results First Posted

September 11, 2020

Record last verified: 2020-08