NCT06054503

Brief Summary

Recently, the threat of viral pandemics (Covid-19, severe acute respiratory syndrome, avian flu H5N1, and H1N1), which might result in thousands of patients requiring mechanical ventilation, has accelerated the need for mechanical ventilation equipment. Disaster may create thousands of critically ill patients requiring mechanical ventilation and may force difficult allocation decisions when demand greatly exceeds supply. Creating a new monitor will only add one more product to the one already used and create confusion for the user. Therefore, the aim is now to develop an independent ventilation module, compatible with the already existing cardiac monitors, which integrates advanced ventilation monitoring functions (mechanical ventilation and RCP). This module could be used by the teams already equipped with multiparametric monitors and be a real added value as the monitoring of the ventilation is critical, especially in emergency situations. Then, it could answer to the clinical need and massively equip every hospital care center in the event of mass casualty incident or viral pandemic. Moreover, this device could be used by emergency teams during daily operations. The aim of this study is to validate a prototype of sensor intended to monitor ventilator parameters of ventilated patients and guide healthcare professionals to provide safe ventilation.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
59

participants targeted

Target at P25-P50 for not_applicable

Timeline
Completed

Started Sep 2023

Shorter than P25 for not_applicable

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

July 12, 2023

Completed
3 months until next milestone

First Posted

Study publicly available on registry

September 26, 2023

Completed
Same day until next milestone

Study Start

First participant enrolled

September 26, 2023

Completed
8 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

June 6, 2024

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

June 6, 2024

Completed
Last Updated

July 16, 2024

Status Verified

September 1, 2023

Enrollment Period

8 months

First QC Date

July 12, 2023

Last Update Submit

July 15, 2024

Conditions

Outcome Measures

Primary Outcomes (1)

  • Number and proportion of patients for whom the insufflated volume measured by the sensor prototype is equivalent to the one measured by the ventilatory monito

    2 hours

Secondary Outcomes (16)

  • Number and proportion of patients for whom the exhaled volume measured by the sensor prototype are equivalent to the one measured by the ventilatory monitor

    2 hours

  • Number and proportion of patients for whom the pressure measured by the sensor prototype are equivalent to the one measured by the ventilatory monitor

    2 hours

  • Number and proportion of patients for whom the flow rate measured by the sensor prototype are equivalent to the one measured by the ventilatory monitor

    2 hours

  • Precision range of the insufflated volume between the sensor prototype and the one measured by the reference ventilator

    2 hours

  • Number and proportion of patients for whom the leak percentage calculated by the sensor prototype are equivalent to the one calculated by the ventilatory monitor ventilator

    2 hours

  • +11 more secondary outcomes

Study Arms (2)

prototype of sensor

EXPERIMENTAL

The patient is his own control

Device: prototype of sensor

ventilator

ACTIVE COMPARATOR

The patient is his own control

Device: prototype of sensor

Interventions

The investigational device is composed of a sensor placed on the respiratory line of the ventilated patients and connected to a ventilation measure unit which records the ventilation parameters

prototype of sensorventilator

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • Male or female patient aged 18 years or above
  • Patient ventilated with the reference ventilators: Servo U - Maquet Critical Care AB, Röntgenvägen 2, 171 54 Solna, Sweden for intensive care unit or Perseus - Drägerwerk AG \& Co. KGaA, Moislinger Allee 53-55, 23542 Lübeck, Germany for operating room
  • Sedated patient with or without NBA (Neuromuscular Blocking Agent)
  • Patient with a positive end-expiratory pressure (PEEP) ≤ 10 cm H2O
  • Patient stable without recent (less than one hour) or planned intervention (such a bronchoscopy, prone positioning, physiotherapy)
  • The primary attending physician approves use of the protocol on the patient
  • Anticipated length of intubation \> 2 hours per patient
  • The patient or legally authorized representative has signed and dated a written Informed Consent Form (ICF) prior to the initiation of any clinical investigation procedures
  • Patient affiliated to the French social security regimen
  • Procedure will be performed at least 30 minutes after inhaled treatment (eg salbutamol)

You may not qualify if:

  • Patient with a serious disease, for which the ventilation unplugging during a few seconds could have a serious impact (particularly patients with PaO2/Fi02 \< 150 with pH \< 7,30, with PEEP \> 10 cm H20, or with Fi02 \> 50%)
  • Patient with disease judged by the investigator to be incompatible with the conduct of the clinical investigation procedures or the interpretation of the clinical investigation results (example: IG-bronchopleural fistula)
  • Patient with a significant lower airway obstruction (asthma…), confirmed by ventilator spirometry.
  • Inability to maintain the airway intubation
  • Patient with a recent history of cardiac and/or respiratory arrest
  • Patient with multiple-organ system failure
  • Patient with hemodynamic instability (tachycardia, rapid change of vasopressor)
  • Pregnancy
  • Participation in another clinical investigation at the same time as the present clinical investigation
  • Nitric oxide use

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

CHU de Besançon

Besançon, 25000, France

Location

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NON RANDOMIZED
Masking
NONE
Purpose
OTHER
Intervention Model
PARALLEL
Model Details: The patient is his own control
Sponsor Type
INDUSTRY
Responsible Party
SPONSOR

Study Record Dates

First Submitted

July 12, 2023

First Posted

September 26, 2023

Study Start

September 26, 2023

Primary Completion

June 6, 2024

Study Completion

June 6, 2024

Last Updated

July 16, 2024

Record last verified: 2023-09

Data Sharing

IPD Sharing
Will not share

Locations