NCT05943028

Brief Summary

The propofol-refentanil program-controlled closed-loop target-controlled infusion system based on NI guidance has been clinically verified. In the case of clinical use of esketamine, the separation anesthesia properties do not affect the accuracy and safety of closed-loop system guidance. However, whether the specific degree of impact can be quantified, and based on quantitative indicators, this model can be better applied to a wider range of clinical actual conditions and different drug administration backgrounds.

Trial Health

35
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Enrollment
48

participants targeted

Target at P50-P75 for early_phase_1

Timeline
Completed

Started Jul 2023

Status
unknown

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

June 27, 2023

Completed
4 days until next milestone

Study Start

First participant enrolled

July 1, 2023

Completed
11 days until next milestone

First Posted

Study publicly available on registry

July 12, 2023

Completed
1.2 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

October 1, 2024

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

October 1, 2024

Completed
Last Updated

July 12, 2023

Status Verified

July 1, 2023

Enrollment Period

1.3 years

First QC Date

June 27, 2023

Last Update Submit

July 5, 2023

Conditions

Keywords

closed-loop TCIEsketaminegeneral anesthesiaNI

Outcome Measures

Primary Outcomes (2)

  • EEG value

    Differences in EEG values between the two groups based on different feedback baselines

    From the beginning to the end of the surgery, an average of 4 hours

  • Anesthesia maintains drug consumption

    Two groups of propofol and refentanil consumption

    From the beginning to the end of the surgery, an average of 4 hours

Secondary Outcomes (3)

  • heart rate

    From the beginning to the end of the surgery, an average of 4 hours

  • Blood pressure

    From the beginning to the end of the surgery, an average of 4 hours

  • pulse

    From the beginning to the end of the surgery, an average of 4 hours

Study Arms (2)

Control group

EXPERIMENTAL

The preset EEG value of 36 in closed-loop target-controlled infusion is the baseline value of EEG closed-loop feedback guidance (obtained by the team's previous research results)

Drug: Subanesthetic dose of esketamine

Experimental group

EXPERIMENTAL

Due to the action of esketamine in closed-loop target-controlled infusion, the EEG preset value of 36+N is the baseline value of the new EEG closed-loop feedback guidance (pre-experiment and literature data, N value is 6-8)

Drug: Subanesthetic dose of esketamine

Interventions

Both groups were given NI-guided propofol-refentanil dual-channel closed-loop target-controlled infusion under general anesthesia with a laryngeal mask/endotracheal intubation. The experimental group (EEG feedback index 36+N) and the control group (EEG feedback index 36) were intravenously injected esketamine 0.2mg∙kg-1 before anesthesia induction, followed by continuous 5μg∙kg-1∙min-1 infusion to maintain anesthesia for 30 minutes, and the maximum cumulative dose allowed was 100mg. In both groups, the infusion was stopped 30 minutes before the end of surgery.

Also known as: Esketamine hydrochloride injection
Control groupExperimental group

Eligibility Criteria

Age18 Years - 55 Years
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64)

You may qualify if:

  • \. Patients undergoing laparoscopic general anesthesia surgery with anesthesia duration \> 60min, 2.18\~55 years old, 3.BMI≥18.5kg/m2, 4. ASA Class I\~II

You may not qualify if:

  • Exclude patients with any of the following criteria:
  • Contraindications to esketamine, propofol or refentanil;
  • Allergic reactions to egg/soy products; Hypersensitivity to fentanyl analogues;
  • Known/suspected neurological diseases, tumors, strokes, neurodegenerative diseases, severe head injuries, seizures, previous EEG abnormalities, cognitive deficits, acquired scalp/skull abnormalities, psychiatric diseases, severe depression, post-traumatic stress disorder, psychosis;
  • Taking psychotropic drugs within the past 7 days,
  • History of substance abuse/abuse or pregnancy in the past 30 days;
  • Currently involved in any other research involving drugs or devices.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Related Publications (2)

  • Liu N, Chazot T, Hamada S, Landais A, Boichut N, Dussaussoy C, Trillat B, Beydon L, Samain E, Sessler DI, Fischler M. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: a randomized multicenter study. Anesth Analg. 2011 Mar;112(3):546-57. doi: 10.1213/ANE.0b013e318205680b. Epub 2011 Jan 13.

    PMID: 21233500BACKGROUND
  • Napoleone G, van Heusden K, Cooke E, West N, Gorges M, Dumont GA, Ansermino JM, Merchant RN. The Effect of Low-Dose Intraoperative Ketamine on Closed-Loop-Controlled General Anesthesia: A Randomized Controlled Equivalence Trial. Anesth Analg. 2021 Nov 1;133(5):1215-1224. doi: 10.1213/ANE.0000000000005372.

    PMID: 33560659BACKGROUND

Study Officials

  • Shengchao Li, Graduate

    The First Clinical College of Southern Medical University

    PRINCIPAL INVESTIGATOR

Central Study Contacts

Bo Xu, professor

CONTACT

Study Design

Study Type
interventional
Phase
early phase 1
Allocation
RANDOMIZED
Masking
TRIPLE
Who Masked
PARTICIPANT, INVESTIGATOR, OUTCOMES ASSESSOR
Masking Details
Participants were assigned to the management and control groups, and neither group of researchers nor subjects was clear about their group. Data statistical analysts and clinical trial participants maintain independence in their work.
Purpose
TREATMENT
Intervention Model
PARALLEL
Model Details: The control group chose the original preset value of 36 as the baseline value of EEG closed-loop feedback guidance (derived from the team's previous research results.The experimental group selected the preset value of 36+N as the baseline value of the new EEG closed-loop feedback guidance (the N value was 6-8 from the pre-experiment).Samples that met the inclusion criteria were randomized and randomly included in the experimental and control groups.
Sponsor Type
OTHER
Responsible Party
SPONSOR INVESTIGATOR
PI Title
professor

Study Record Dates

First Submitted

June 27, 2023

First Posted

July 12, 2023

Study Start

July 1, 2023

Primary Completion

October 1, 2024

Study Completion

October 1, 2024

Last Updated

July 12, 2023

Record last verified: 2023-07

Data Sharing

IPD Sharing
Will not share

Data collection is recorded from anesthesia records in the original medical record and uploaded to Data Digital for sharing and management(https://www.bcg.com/publications/2022/how-to-build-a-data-and-digital-strategy)