SurePulse Oximeter - a Targeted Oxygenation Observation
SPO-TOO
3 other identifiers
interventional
19
1 country
1
Brief Summary
This clinical investigation will investigate how accurate the SurePulse VS and SurePulse VS Patch (VSP) are for measuring blood oxygen levels (oxygen saturation). If the results are accurate, the VSP will be ready to apply for regulatory approval, meaning it could then be available for use on newborn babies in the National Health Service (NHS).
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable healthy
Started Apr 2023
Shorter than P25 for not_applicable healthy
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 3, 2023
CompletedFirst Posted
Study publicly available on registry
March 6, 2023
CompletedStudy Start
First participant enrolled
April 27, 2023
CompletedPrimary Completion
Last participant's last visit for primary outcome
July 26, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
July 26, 2023
CompletedAugust 1, 2023
July 1, 2023
3 months
February 3, 2023
July 28, 2023
Conditions
Keywords
Outcome Measures
Primary Outcomes (2)
Validation of the SpO2 accuracy of the SurePulse VS Patch Newborn Vital Sign Monitor (VSP) pulse oximeter in comparison to "gold-standard" measurements of blood SaO2 by a co-oximeter.
Oxygen saturation comparison of measurements taken by the SurePulse VSP (SpO2) and co-oximeter blood gas analyser (SaO2). For the statistical analysis, the Accuracy Root Mean Square (Arms) calculation is used to determine the SpO2 accuracy performance.
Through study completion, an average of 2 hours
Adverse events (AEs) attributable to the SurePulse medical devices
Incidence, severity and causality of all AEs with delineation of those that are attributable to the use of the SurePulse medical devices to be used as a measure of device safety. Safety is measured by adverse events attributable to SurePulse medical devices and will be measured by adverse event logs and reports and their associated reporting requirements.
Through study completion, an average of 2 hours
Secondary Outcomes (3)
Validation of the SpO2 accuracy of the SurePulse VS Monitor (VS) in comparison to "gold-standard" measurements of blood SaO2 by a co-oximeter.
Through study completion, an average of 2 hours
Validation of the pulse rate accuracy of the SurePulse VS Patch Newborn Vital Sign Monitor (VSP) pulse oximeter in comparison to ECG.
Through study completion, an average of 2 hours
Validation of the pulse rate accuracy of the SurePulse VS Monitor (VS) in comparison to ECG.
Through study completion, an average of 2 hours
Study Arms (1)
SurePulse VS and VSP devices
EXPERIMENTALAll enrolled participants will undergo a controlled and stepwise reduction in oxygen blood levels, with both the SurePulse VS/SurePulse VSP placed on the volunteer.
Interventions
A controlled and stepwise reduction in oxygen blood levels in healthy volunteers, with the SurePulse VSP placed on the volunteer.
A controlled and stepwise reduction in oxygen blood levels in healthy volunteers, with the SurePulse VS placed on the volunteer.
Eligibility Criteria
You may qualify if:
- Age 18 to 55
- Willing and able to provide written informed consent
- Healthy adult subjects (ASA 1)
- Non-smoker
- Willing and able to comply with study procedures and duration
You may not qualify if:
- Smokers or individuals exposed to high levels of carbon monoxide
- Compromised circulation, injury, or physical malfunction of the sensor sites which would limit the ability to test sites needed for the study
- Female subjects that are actively trying to get pregnant or are pregnant (confirmed by Health Assessment Form). N.B. All female participants will be offered a pregnancy test
- Unwillingness or inability to remove coloured nail polish from test digits (relevant for reference pulse oximeter) or to have medical monitoring attached
- Known health conditions disclosed on Health Assessment Form which mean that participant is not healthy
- Allergy to lidocaine
- Allergy to adhesives used in medical dressings or tapes
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
University Hospitals Birmingham NHS Foundation Trust
Birmingham, United Kingdom
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Murray du Plessis
University Hospital Birmingham NHS Foundation Trust
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Masking Details
- No masking
- Purpose
- DEVICE FEASIBILITY
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
February 3, 2023
First Posted
March 6, 2023
Study Start
April 27, 2023
Primary Completion
July 26, 2023
Study Completion
July 26, 2023
Last Updated
August 1, 2023
Record last verified: 2023-07
Data Sharing
- IPD Sharing
- Will not share