NCT05725473

Brief Summary

Benign esophageal strictures are frequently seen in endoscopic practice and are caused by a variety of esophageal disorders, including peptic, radiotherapy-induced and caustic injuries, Schatzki ring, eosinophilic esophagitis (EoE), and strictures after surgical resection (anastomotic) or endoscopic resection (endoscopic mucosal resection-EMR- and endoscopic submucosal dissection-ESD), and ablative therapies (Radiofrequency, Cryotherapy and Argon-plasma coagulation). Endoscopic dilation is the first treatment step for benign esophageal strictures. Two types of dilators are available, namely, through-the-scope balloon dilators, with or without a guidewire, and wire-guided bougie dilators. Bougie dilators are used for simple strictures and for strictures in the proximal esophagus, especially anastomotic strictures. Bougie dilators exert a combined radial and longitudinal force, which may increase the risk of perforation. Bougie dilators allow, however, sensing the degree of resistance during dilation, and thereby help determining increasing bougie sizes during next-step dilations. Through the-scope balloon dilators are preferred for complex strictures. Balloons dilators allow direct visualization and control of the radially applied dilation force. In literature, both dilation techniques appear to be equally effective and safe in the management of esophageal strictures, showing no differences in terms of risks of AEs About 30 years ago, the "rule of three" has been published. This rule dictated the extent of dilation during any endoscopic session (i.e., no more than three dilators successively larger than the first dilator to meet resistance were passed) and has been used by endoscopists to reduce the risk of perforation. However, the safety of the "rule of three" has never been demonstrated. Moreover, a recent study suggests that more than three dilation steps per session may be considered for esophageal strictures, with the exception of malignant strictures. The EsoFLIP (Medtronic Inc., Shoreview, MN, USA) is a novel dilation balloon that provides real-time, objective visualization and monitoring of therapeutic dilation. EsoFLIP utilizes high-resolution impedance planimetry to provide real-time measurements (diameter and cross-sectional area) of the stenotic area before, during, and at the end of the dilation without the need of fluoroscopy. In 2013, technical feasibility and safety of the EsoFLIP in esophago-gastric junction (EGJ) dilation have been demonstrated on porcine models. In a small first pilot study, the technical feasibility of the EsoFLIP device in 10 patients with achalasia has been demonstrated. A second study reported short-term efficacy, both objective (improvement in barium column) and subjective (improvement in Eckardt score), in 28 patients managed using the FLIP hydraulic balloon dilator. Very limited data are currently available in the literature on the use of EsoFLIP in benign esophageal strictures dilation. Potential advantages of the use of EsoFLIP are dilation without fluoroscopy and associated radiation, control of dilation sizes to generate the desired dilation effect and assessment of stricture size and the response to dilatation immediately following dilation. In a small single centre retrospective study on 19 paediatric patients, use of EsoFLIP hydraulic dilation was safe and provided a larger diameter increase compared with standard balloon dilation, but this was not statistically significant likely because of the small cohort size. The study also suggested that procedure time and fluoroscopy time were shorter in the EsoFLIP cases when compared to other traditional dilation methods. Esophageal dilation using EsoFLIP may yield a larger diameter change increasing the interval between a dilatation procedure and the following one and may potentially reduce procedure time when compared to traditional balloon dilation. There is currently no published prospective study about dilation with EsoFLIP in adult patients affected by benign esophageal strictures. The endoluminal functional lumen imaging probe, EndoFLIP™ (Medtronic, Minneapolis, MN, USA) (FLIP), is a tool that utilizes impedance planimetry, a technique for performing balloon distention in the alimentary track, to obtain dynamic measurements of any sphincters including the diameter, cross-sectional area (CSA), and distensibility index (DI). Diseases where Endo-FLIP has been employed include esophageal stenosis, reflux esophagitis, eosinophilic esophagitis, gastroparesis, anal sphincter disease, achalasia, and it has also been used in peroral endoscopic myotomy.

Trial Health

43
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Enrollment
15

participants targeted

Target at below P25 for not_applicable

Timeline
Completed

Started Jan 2023

Geographic Reach
1 country

1 active site

Status
unknown

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

January 12, 2023

Completed
12 days until next milestone

First Submitted

Initial submission to the registry

January 24, 2023

Completed
20 days until next milestone

First Posted

Study publicly available on registry

February 13, 2023

Completed
1.4 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

June 30, 2024

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

June 30, 2024

Completed
Last Updated

February 13, 2023

Status Verified

February 1, 2023

Enrollment Period

1.5 years

First QC Date

January 24, 2023

Last Update Submit

February 2, 2023

Conditions

Outcome Measures

Primary Outcomes (1)

  • Clinical efficacy

    Reduction of severity and frequency of dysphagia (Brief Esophageal Dysphagia Questionnaire, Likert scale, BEDQ)

    12 months

Study Arms (1)

Eso-Flip

EXPERIMENTAL

Dilatation with Eso-Flip

Device: Eso-Flip

Interventions

Eso-FlipDEVICE

Dilatation with Eso-FLIP

Eso-Flip

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • Dysphagia due to benign esophageal stricture (e.g. surgery, radiation therapy, caustic ingestion, peptic injury, photodynamic therapy, EoE)
  • A benign esophageal stricture requiring endoscopic esophageal dilation (naïve and refractory to previous treatments)

You may not qualify if:

  • Patient with known esophageal motility disorder (such as achalasia)
  • Patient unable to give consent to the participation of the clinical study

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Endoscopy Unit, Gastroenterology Department, Humanitas Research Hospital

Rozzano, Milano, 20089, Italy

RECRUITING

MeSH Terms

Conditions

Esophageal Neoplasms

Condition Hierarchy (Ancestors)

Gastrointestinal NeoplasmsDigestive System NeoplasmsNeoplasms by SiteNeoplasmsHead and Neck NeoplasmsDigestive System DiseasesEsophageal DiseasesGastrointestinal Diseases

Central Study Contacts

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NA
Masking
NONE
Purpose
TREATMENT
Intervention Model
SINGLE GROUP
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

January 24, 2023

First Posted

February 13, 2023

Study Start

January 12, 2023

Primary Completion

June 30, 2024

Study Completion

June 30, 2024

Last Updated

February 13, 2023

Record last verified: 2023-02

Data Sharing

IPD Sharing
Will not share

Locations