NCT05235321

Brief Summary

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. The purpose of this study is to develop an automated and objective method for performing applanation tonometry using standard ophthalmic equipment as well as using 2 portable prototypes.

Trial Health

57
Monitor

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
111

participants targeted

Target at P50-P75 for not_applicable

Timeline
Completed

Started Nov 2022

Geographic Reach
1 country

1 active site

Status
terminated

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

February 2, 2022

Completed
9 days until next milestone

First Posted

Study publicly available on registry

February 11, 2022

Completed
9 months until next milestone

Study Start

First participant enrolled

November 21, 2022

Completed
1.5 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

May 31, 2024

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

May 31, 2024

Completed
Last Updated

June 13, 2025

Status Verified

June 1, 2025

Enrollment Period

1.5 years

First QC Date

February 2, 2022

Last Update Submit

June 11, 2025

Conditions

Outcome Measures

Primary Outcomes (4)

  • Intraocular pressure (IOP) as measured by standard GAT

    this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.

    Baseline

  • Intraocular pressure (IOP) as measured by fixed force GAT

    From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular.

    Baseline

  • Intraocular pressure as measured by upright applanating

    With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.

    Baseline

  • Intraocular pressure as measured by supine applanating protoype

    With this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.

    Baseline

Study Arms (4)

Standard GAT

ACTIVE COMPARATOR

This is the standard method for IOP measurement in clinical practice

Device: Standard GAT

Fixed-force GAT

EXPERIMENTAL

From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter

Device: Fixed force GAT

Upright applanating prototype

EXPERIMENTAL

With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter

Device: Upright applanating prototype

Supine Applanating Prototype

EXPERIMENTAL

With this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter

Device: Supine Applanating Prototype

Interventions

Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice

Standard GAT

An investigational device similar to standard GAT

Fixed-force GAT

An investigational device, prism used in standard and fixed-force GAT is attached to a portable device

Upright applanating prototype

An investigational device, prism used in standard and fixed-force GAT is attached to a portable device performed in the supine position

Supine Applanating Prototype

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • Presenting for a routine eye exam
  • ≥ 18 years of age
  • Able and willing to give consent

You may not qualify if:

  • History of corneal scarring
  • Active infection of the eye

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Duke Eye Center

Durham, North Carolina, 27710, United States

Location

MeSH Terms

Conditions

GlaucomaOcular Hypertension

Condition Hierarchy (Ancestors)

Eye Diseases

Study Officials

  • Joanne Wen, MD

    Duke Eye Center

    PRINCIPAL INVESTIGATOR

Study Design

Study Type
interventional
Phase
not applicable
Allocation
RANDOMIZED
Masking
NONE
Purpose
DIAGNOSTIC
Intervention Model
PARALLEL
Model Details: In this study, 3 eye pressure measurements will be made in the upright position (standard GAT, fixed force GAT, upright applanating prototype) and 1 in the supine position (supine applanating prototype).
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

February 2, 2022

First Posted

February 11, 2022

Study Start

November 21, 2022

Primary Completion

May 31, 2024

Study Completion

May 31, 2024

Last Updated

June 13, 2025

Record last verified: 2025-06

Data Sharing

IPD Sharing
Will not share

No Currently, there is no plan to share data with other researchers.