Study Stopped
device updates needed
Automated Applanation Tonometry
1 other identifier
interventional
111
1 country
1
Brief Summary
Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. The purpose of this study is to develop an automated and objective method for performing applanation tonometry using standard ophthalmic equipment as well as using 2 portable prototypes.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Nov 2022
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 2, 2022
CompletedFirst Posted
Study publicly available on registry
February 11, 2022
CompletedStudy Start
First participant enrolled
November 21, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
May 31, 2024
CompletedStudy Completion
Last participant's last visit for all outcomes
May 31, 2024
CompletedJune 13, 2025
June 1, 2025
1.5 years
February 2, 2022
June 11, 2025
Conditions
Outcome Measures
Primary Outcomes (4)
Intraocular pressure (IOP) as measured by standard GAT
this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.
Baseline
Intraocular pressure (IOP) as measured by fixed force GAT
From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular.
Baseline
Intraocular pressure as measured by upright applanating
With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.
Baseline
Intraocular pressure as measured by supine applanating protoype
With this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.
Baseline
Study Arms (4)
Standard GAT
ACTIVE COMPARATORThis is the standard method for IOP measurement in clinical practice
Fixed-force GAT
EXPERIMENTALFrom the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Upright applanating prototype
EXPERIMENTALWith this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Supine Applanating Prototype
EXPERIMENTALWith this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Interventions
Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice
An investigational device, prism used in standard and fixed-force GAT is attached to a portable device
An investigational device, prism used in standard and fixed-force GAT is attached to a portable device performed in the supine position
Eligibility Criteria
You may qualify if:
- Presenting for a routine eye exam
- ≥ 18 years of age
- Able and willing to give consent
You may not qualify if:
- History of corneal scarring
- Active infection of the eye
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Duke Universitylead
Study Sites (1)
Duke Eye Center
Durham, North Carolina, 27710, United States
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Joanne Wen, MD
Duke Eye Center
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Purpose
- DIAGNOSTIC
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
February 2, 2022
First Posted
February 11, 2022
Study Start
November 21, 2022
Primary Completion
May 31, 2024
Study Completion
May 31, 2024
Last Updated
June 13, 2025
Record last verified: 2025-06
Data Sharing
- IPD Sharing
- Will not share
No Currently, there is no plan to share data with other researchers.