NCT05162313

Brief Summary

This is a multicentre clinical trial with medical device. As currently recommended by international neonatal resuscitation guidelines, the most reliable method to verify the correct positioning of the endotracheal tube, in association with clinical signs, is the end-tidal capnometry obtained either by infrared spectroscopy or colorimetric method. The aim of the present study is to evaluate whether the flow sensor of a standard mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube after a tracheal intubation attempt compared to the colorimetric capnometer, in newborns undergoing this procedure during hospitalization in the neonatal intensive care unit. Given the importance of defining a rapid and effective method to prevent possible adverse events of incorrect endotracheal intubation, this study aims to verify whether the ventilator flow sensor can allow a reliable assessment of the correct positioning of the endotracheal tube, with timing and success rates equivalent to or better than the colorimetric capnometer.

Trial Health

43
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Enrollment
105

participants targeted

Target at P50-P75 for not_applicable

Timeline
Completed

Started Feb 2022

Geographic Reach
1 country

1 active site

Status
unknown

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

December 6, 2021

Completed
11 days until next milestone

First Posted

Study publicly available on registry

December 17, 2021

Completed
2 months until next milestone

Study Start

First participant enrolled

February 10, 2022

Completed
1.1 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

April 1, 2023

Completed
2 months until next milestone

Study Completion

Last participant's last visit for all outcomes

June 1, 2023

Completed
Last Updated

March 8, 2022

Status Verified

March 1, 2022

Enrollment Period

1.1 years

First QC Date

December 6, 2021

Last Update Submit

March 7, 2022

Conditions

Keywords

tracheal intubationtracheal tube positioningcolorimetric capnometerflow sensorinvasive mechanical ventilationnewbornpreterm infant

Outcome Measures

Primary Outcomes (2)

  • Time taken by the flow-sensor to indicate the correct or not correct positioning of the tracheal tube, compared with time taken by the colorimetric capnometer.

    To compare the time (expressed in seconds) taken by the flow sensor and the colorimetric capnometer, respectively, to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure during neonatal intensive care unit admission. The aim is to evaluate if the flow sensor of the mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube during the tracheal intubation procedure compared to the colorimetric capnometer.

    Immediately after the tracheal intubation attempt

  • Number of mechanical breaths necessary to indicate the correct or not correct positioning of the tracheal tube by evaluating the flow-sensor curves and the color change of the colorimetric capnometer.

    To compare the minimal number of mechanical breaths provided by the ventilator to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure, either evaluating the flow-sensor curves and the color change of the colorimetric capnometer, respectively. The aim is to evaluate if the flow sensor of the mechanical ventilator can indicate with lower or equal number of mechanical breaths the correct positioning of the tube during tracheal intubation compared to the colorimetric capnometer.

    Immediately after the tracheal intubation attempt

Study Arms (1)

all patients undergoing tracheal intubation procedure

OTHER

In current practice, the endotracheal intubation procedure includes the systematic use of the capnometer, which is immediately connected to the tube after its insertion by direct laringoscopy. Confirmation of the correct tube positioning is established by color change of the capnometer from violet to yellow. Then, the colorimetric capnometer is usually removed before connecting the endotracheal tube to the flow-sensor of the ventilator. For the purpose of our study, after the tube insertion the care provider will connect in line both the capnometer and the ventilator flow-sensor to the tracheal tube.

Device: confirmation of endotracheal tube positioning

Interventions

After performing the tube insertion by direct laryngoscopy, videolaringoscopy or fiberoptic technique, the attending neonatologist will connect both the colorimetric capnometer and the proximal flow-sensor to the tracheal tube. If the flow sensor is not proximal but incorporated into the mechanical ventilator, the care provider will connect the capnometer only. During the procedure, the information given by the capnometer will be evaluated by the care provider performing the intubation, while the flow sensor information will be monitored only by a study investigator, who will not reveal any details to the care provider. In particular, the yellow color change by the capnometer and the presence of exhalation flow curves on the ventilator screen will be considered as confirmation of correct tracheal tube positioning, respectively.

all patients undergoing tracheal intubation procedure

Eligibility Criteria

Age20 Minutes - 3 Months
Sexall
Healthy VolunteersNo
Age GroupsChild (0-17)

You may qualify if:

  • Term and preterm infants requiring tracheal intubation within the neonatal intensive care unit, both in elective and emergency conditions.

You may not qualify if:

  • intubation at birth
  • intubation during cardiopulmonary resuscitation
  • absence of informed consent by parents

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Azienda Ospedaliera Universitaria Integrata Verona

Verona, 37126, Italy

RECRUITING

MeSH Terms

Conditions

Premature Birth

Condition Hierarchy (Ancestors)

Obstetric Labor, PrematureObstetric Labor ComplicationsPregnancy ComplicationsFemale Urogenital Diseases and Pregnancy ComplicationsUrogenital Diseases

Central Study Contacts

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NA
Masking
NONE
Masking Details
Participants are newborns. The care provider will be the attending physician performing the tracheal intubation procedure as per local protocols, including the colourimetric capnometry analysis. However, he/she will remain blind and not aware of the flow sensor data until the end of the procedure.
Purpose
DIAGNOSTIC
Intervention Model
SINGLE GROUP
Model Details: Simultaneous assignment, as the two methods to confirm the endotracheal tube position, namely the colorimetric capnometer and the flow sensor signal, will be evaluated simultaneously in each recruited patient.
Sponsor Type
OTHER
Responsible Party
PRINCIPAL INVESTIGATOR
PI Title
Director, Neonatal Intensive Care Unit, Dept. Neonatal and Pediatric Critical Care

Study Record Dates

First Submitted

December 6, 2021

First Posted

December 17, 2021

Study Start

February 10, 2022

Primary Completion

April 1, 2023

Study Completion

June 1, 2023

Last Updated

March 8, 2022

Record last verified: 2022-03

Locations