Flow Sensor and Colourimetric Capnometer in Verifying Tracheal Tube Positioning in Term and Preterm Infants
FlowNET
Comparison Between Flow Sensor and Colourimetric Capnometer in Verifying the Correct Positioning of the Endotracheal Tube in Term and Preterm Infants
1 other identifier
interventional
105
1 country
1
Brief Summary
This is a multicentre clinical trial with medical device. As currently recommended by international neonatal resuscitation guidelines, the most reliable method to verify the correct positioning of the endotracheal tube, in association with clinical signs, is the end-tidal capnometry obtained either by infrared spectroscopy or colorimetric method. The aim of the present study is to evaluate whether the flow sensor of a standard mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube after a tracheal intubation attempt compared to the colorimetric capnometer, in newborns undergoing this procedure during hospitalization in the neonatal intensive care unit. Given the importance of defining a rapid and effective method to prevent possible adverse events of incorrect endotracheal intubation, this study aims to verify whether the ventilator flow sensor can allow a reliable assessment of the correct positioning of the endotracheal tube, with timing and success rates equivalent to or better than the colorimetric capnometer.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Feb 2022
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
December 6, 2021
CompletedFirst Posted
Study publicly available on registry
December 17, 2021
CompletedStudy Start
First participant enrolled
February 10, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
April 1, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
June 1, 2023
CompletedMarch 8, 2022
March 1, 2022
1.1 years
December 6, 2021
March 7, 2022
Conditions
Keywords
Outcome Measures
Primary Outcomes (2)
Time taken by the flow-sensor to indicate the correct or not correct positioning of the tracheal tube, compared with time taken by the colorimetric capnometer.
To compare the time (expressed in seconds) taken by the flow sensor and the colorimetric capnometer, respectively, to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure during neonatal intensive care unit admission. The aim is to evaluate if the flow sensor of the mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube during the tracheal intubation procedure compared to the colorimetric capnometer.
Immediately after the tracheal intubation attempt
Number of mechanical breaths necessary to indicate the correct or not correct positioning of the tracheal tube by evaluating the flow-sensor curves and the color change of the colorimetric capnometer.
To compare the minimal number of mechanical breaths provided by the ventilator to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure, either evaluating the flow-sensor curves and the color change of the colorimetric capnometer, respectively. The aim is to evaluate if the flow sensor of the mechanical ventilator can indicate with lower or equal number of mechanical breaths the correct positioning of the tube during tracheal intubation compared to the colorimetric capnometer.
Immediately after the tracheal intubation attempt
Study Arms (1)
all patients undergoing tracheal intubation procedure
OTHERIn current practice, the endotracheal intubation procedure includes the systematic use of the capnometer, which is immediately connected to the tube after its insertion by direct laringoscopy. Confirmation of the correct tube positioning is established by color change of the capnometer from violet to yellow. Then, the colorimetric capnometer is usually removed before connecting the endotracheal tube to the flow-sensor of the ventilator. For the purpose of our study, after the tube insertion the care provider will connect in line both the capnometer and the ventilator flow-sensor to the tracheal tube.
Interventions
After performing the tube insertion by direct laryngoscopy, videolaringoscopy or fiberoptic technique, the attending neonatologist will connect both the colorimetric capnometer and the proximal flow-sensor to the tracheal tube. If the flow sensor is not proximal but incorporated into the mechanical ventilator, the care provider will connect the capnometer only. During the procedure, the information given by the capnometer will be evaluated by the care provider performing the intubation, while the flow sensor information will be monitored only by a study investigator, who will not reveal any details to the care provider. In particular, the yellow color change by the capnometer and the presence of exhalation flow curves on the ventilator screen will be considered as confirmation of correct tracheal tube positioning, respectively.
Eligibility Criteria
You may qualify if:
- Term and preterm infants requiring tracheal intubation within the neonatal intensive care unit, both in elective and emergency conditions.
You may not qualify if:
- intubation at birth
- intubation during cardiopulmonary resuscitation
- absence of informed consent by parents
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Azienda Ospedaliera Universitaria Integrata Verona
Verona, 37126, Italy
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Masking Details
- Participants are newborns. The care provider will be the attending physician performing the tracheal intubation procedure as per local protocols, including the colourimetric capnometry analysis. However, he/she will remain blind and not aware of the flow sensor data until the end of the procedure.
- Purpose
- DIAGNOSTIC
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Director, Neonatal Intensive Care Unit, Dept. Neonatal and Pediatric Critical Care
Study Record Dates
First Submitted
December 6, 2021
First Posted
December 17, 2021
Study Start
February 10, 2022
Primary Completion
April 1, 2023
Study Completion
June 1, 2023
Last Updated
March 8, 2022
Record last verified: 2022-03