NCT04313595

Brief Summary

Patients at risk of developing respiratory dysfunctions, such as patients with severe forms of muscular dystrophy, need a careful respiratory assessment, and periodic follow-up visits to monitor the progression of the disease. Continuous monitoring of respiratory activity pattern at home could give additional understandings about disease progression, flanking traditional, intermittent, cardiopulmonary evaluations, allowing prompt clinical intervention, and anticipating respiratory dysfunction. The main objective of the present study is thus to investigate the feasibility of using an innovative wearable device for respiratory monitoring, especially breathing frequency variation assessment, in patients with muscular dystrophy. The comparison between the measurements of breathing frequency obtained by using the IMU-based device and by using the reference method provided optimal results, in terms of accuracy errors, correlation and agreement. Participants positively evaluated the device for what concerns ease of use, comfort, usability and wearability. Moreover, preliminary results confirmed that breathing frequency is an interesting breathing parameter to monitor, at the clinic and at home, because it strongly correlates with the main indexes of respiratory function

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
15

participants targeted

Target at below P25 for not_applicable

Timeline
Completed

Started Jul 2018

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

July 29, 2018

Completed
12 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

July 15, 2019

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

July 15, 2019

Completed
8 months until next milestone

First Submitted

Initial submission to the registry

February 26, 2020

Completed
21 days until next milestone

First Posted

Study publicly available on registry

March 18, 2020

Completed
Last Updated

March 18, 2020

Status Verified

March 1, 2020

Enrollment Period

12 months

First QC Date

February 26, 2020

Last Update Submit

March 17, 2020

Conditions

Outcome Measures

Primary Outcomes (3)

  • Safety of the device

    Recording of any adverse events

    After 24 hours of continued use

  • Usability of the device (System Usability Scale)

    System Usability Scale (SUS acceptance and wearability of the device):the scores range from 0 to 100 in 2.5-point increments, with higher values meaning high perceived usability of the system

    After 24 hours of continued use

  • Acceptability of the device (Technological Acceptance Measure)

    Technological Acceptance Measure (TAM) questionnaire appropriate for the medical device: with higher values meaning high acceptance of the system

    After 24 hours of continued use

Secondary Outcomes (1)

  • Accuracy in measuring the breathing frequency

    Immediately after application of the device

Study Arms (1)

Breathing frequency monitoring

EXPERIMENTAL
Device: RespirHó

Interventions

RespirHóDEVICE

The system is a wearable, unobtrusive inertial-sensor-based device for long-term breathing pattern monitoring, also during daily life activities. It consists of three IMU-sensor units (3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer), positioned respectively on the patient's abdomen and thorax, and on a body area integral with thorax but not affected by espiratory movements. The peripheral units, placed on thorax and abdomen are used to record orientation changes during respiratory movements. The third unit is a central reference unit (hereafter CRU) that receives data from the other two units, save them on an SD card and communicate via Bluetooth with a smartphone / tablet / PC. Moreover, this unit detects only non-respiratory movement, representing not only a pure source of "noise" that must be removed from the thoracic and bdominal signals, but also a pure source of additional information regarding the state of ctivity of the subject .

Breathing frequency monitoring

Eligibility Criteria

Sexall
Healthy VolunteersNo
Age GroupsChild (0-17), Adult (18-64), Older Adult (65+)

You may qualify if:

  • documented DMD or LGMD2
  • loss of independent ambulation (wheelchair-bound patients)
  • ability to understand and follow test instructions and to report pain and discomfort.

You may not qualify if:

  • presence of metal implants and cardiac pacemakers
  • relevant concomitant comorbidities (e.g.epilepsy)
  • behaviour and/or psychiatric disorders (e.g. emotional problems, anxiety, panic attacks).

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

IRCCS Medea

Bosisio Parini, Lecco, 23842, Italy

Location

MeSH Terms

Conditions

Muscular Dystrophies

Condition Hierarchy (Ancestors)

Muscular Disorders, AtrophicMuscular DiseasesMusculoskeletal DiseasesNeuromuscular DiseasesNervous System DiseasesGenetic Diseases, InbornCongenital, Hereditary, and Neonatal Diseases and Abnormalities

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NA
Masking
NONE
Purpose
SUPPORTIVE CARE
Intervention Model
SINGLE GROUP
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

February 26, 2020

First Posted

March 18, 2020

Study Start

July 29, 2018

Primary Completion

July 15, 2019

Study Completion

July 15, 2019

Last Updated

March 18, 2020

Record last verified: 2020-03

Data Sharing

IPD Sharing
Will not share

Locations