Bio Impedance-assisted Monitoring of Chronic Hemodialysis Patients
Regional Electric Bio Impedance-assisted Monitoring of Cardiac, Vascular Resistance and Fluid Balance, in Chronic Hemodialysis Patients
1 other identifier
interventional
30
1 country
1
Brief Summary
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment. Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters. Technology for hemodynamic measurements: The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'. SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1). Figure 1 : Sensor location SV is calculated by Frinerman's formula: SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF \[2-4\], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula \[11\]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure \[2 - (diastolicsystolic)/3\], cardiac power index \[CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2\] \[12, 13\] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) \[13\] will be calculated. As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments \[9\]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Nov 2018
Typical duration for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
November 18, 2018
CompletedFirst Submitted
Initial submission to the registry
October 13, 2019
CompletedFirst Posted
Study publicly available on registry
October 16, 2019
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 31, 2019
CompletedStudy Completion
Last participant's last visit for all outcomes
December 31, 2020
CompletedOctober 16, 2019
October 1, 2019
1.1 years
October 13, 2019
October 13, 2019
Conditions
Outcome Measures
Primary Outcomes (1)
Hemodynamic adverse events
Extreme blood pressure decrease, hospitalization, death
One year
Study Arms (2)
CHRONIC HEMODIALYSIS PATIENTS, NICAS-ASSISTED MONITORING
EXPERIMENTALChronic hemodialysis patients, NICAS-assisted monitored
Control hemodialysis patients
NO INTERVENTIONChronic hemodialysis patients, conventional clinical care and monitoring.
Interventions
Electric regional bio impedance device
Eligibility Criteria
You may qualify if:
- Chronic hemodialysis patients
You may not qualify if:
- Age limits
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Nephrology and Hypertention Institute, hemodialysis unit
Ashdod, 7747629, Israel
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Adi Leiba, Prof
ASSUTA HOSPITAL ASHDOD
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Purpose
- PREVENTION
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Proffesor Adi Leiba, head, Nephrology and Hypertension Institute,
Study Record Dates
First Submitted
October 13, 2019
First Posted
October 16, 2019
Study Start
November 18, 2018
Primary Completion
December 31, 2019
Study Completion
December 31, 2020
Last Updated
October 16, 2019
Record last verified: 2019-10
Data Sharing
- IPD Sharing
- Will not share