Biosensors for Open and Closed-loop Glycemia Control in T1D Patients With Insulin Pump
DIABLO
Decoding Islet Algorithms in Biosensors for Open and Closed-loop Glycemia Control in T1D Patients With Insulin Pump Coupled to Sensors.
2 other identifiers
interventional
1
1 country
1
Brief Summary
In T1D, the destruction of beta-pancreatic cells causes insulin deficiency and requires insulin therapy whose control remains complex: even with recent technologies of continuous measurement and monitoring of blood glucose (CGM), current systems are electrochemical, insulin therapy algorithms do not are not optimal and cannot completely eliminate vital risks such as hypoglycemia. A new biosensor connected to the patient by microdialysis, will be tested in a clinical trial in CHU-Bdx on 10 T1D patients with an internal or external insulin pump. In various daily scenarios (meals, physical exercise) the biosensor DIABLO responses will be compared to the measurements of standard CGM systems.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Jan 2023
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
September 4, 2019
CompletedFirst Posted
Study publicly available on registry
September 9, 2019
CompletedStudy Start
First participant enrolled
January 27, 2023
CompletedPrimary Completion
Last participant's last visit for primary outcome
January 27, 2024
CompletedStudy Completion
Last participant's last visit for all outcomes
January 27, 2024
CompletedMay 22, 2026
March 1, 2024
1 year
September 4, 2019
May 21, 2026
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Comparison between biosensor to CGMS responses
Measure blood glucose every 10 minutes by taking interstitial fluid from DT1 patients with an internal or external insulin pump to compare the biosensor responses to measurements of standard CGM systems.
2 days after inclusion
Study Arms (1)
Biosensor algorithm
EXPERIMENTALThe biosensor DIABLO algorithm is compared to Continuous Glucose Monitoring Systems (CGMS) utilisation.
Interventions
The biosensor DIABLO responses will be compared to the measurements of standard CGMS, using blood glucose measures every 10 minutes by taking interstitial fluid from Diabetes Type 1 (DT1) patients with an internal or external insulin pump.
Eligibility Criteria
You may qualify if:
- Patient over 18 years of age
- Patient with type 1 diabetes (T1D)
- Patient being equipped and trained with an external or internan insulin pump linked to a CGM
- Affiliated person or beneficiary of a social security scheme
- Free, informed and written consent
You may not qualify if:
- Patient under 18 years
- Patient not having T2D
- Pregnant or lactating patient
- No consent signed by the patient
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Hôpital Saint-André
Bordeaux, 33000, France
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Bogdan CATARGI, Pr
University Hospital, Bordeaux
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- TREATMENT
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
September 4, 2019
First Posted
September 9, 2019
Study Start
January 27, 2023
Primary Completion
January 27, 2024
Study Completion
January 27, 2024
Last Updated
May 22, 2026
Record last verified: 2024-03