NCT03890627

Brief Summary

Pulmonary Hypertension (PH) is a rare disease characterized by an increase in pulmonary vascular resistance, leading to a progressive decline in cardiac output (CO).Since cardiac output is correlated with the prognosis of the disease, the conduct of a right heart catheterization (thermodilution measurement, reference technique) during the annual follow-up visit of patients in competences centres is recommended. In practice, it is not systematically performed because of it is invasive, with potential risk for the patient, and there is limited logistical capacity for its implementation. The estimation of cardiac output is thus often based on cardiac ultrasound but its measurement is potentially biased. Starling ™ SV is a non-invasive cardiac output monitor based on thoracic bio-reactance measurement. Several clinical studies have shown that cardiac output measured by bio-reactance is strongly correlated with the measurement obtained by catheterization in different indications. Rich et al. (2013) assessed bio-reactance specifically in 50 patients with Pulmonary Hypertension compared with thermodilution. The results showed that the measurement of cardiac output by bio-reactance was feasible in these patients, had a better accuracy than by catheterization, and was reliable for detecting changes in cardiac output after a vasodilatation test. The Starling ™ SV monitor could thus have a place in the follow-up of patients who are being treated for Pulmonary Hypertension. Since it is a rapid, non-invasive examination, it could be performed on an outpatient basis, especially as a first-line test to check the stability of the CO, thus avoiding the systematic use of right heart catheterization, which would then be reserved only to patients for whom the measurement by bio-reactance would show a decrease of cardiac output compared to the previous value. Before being able to propose this use in current practice, it is necessary to carry out a pilot study which will make it possible to explore the interest of bio-reactance in this situation.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
60

participants targeted

Target at P25-P50 for all trials

Timeline
Completed

Started May 2019

Typical duration for all trials

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

March 25, 2019

Completed
1 day until next milestone

First Posted

Study publicly available on registry

March 26, 2019

Completed
2 months until next milestone

Study Start

First participant enrolled

May 21, 2019

Completed
3 years until next milestone

Primary Completion

Last participant's last visit for primary outcome

May 31, 2022

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

May 31, 2022

Completed
Last Updated

October 13, 2022

Status Verified

October 1, 2022

Enrollment Period

3 years

First QC Date

March 25, 2019

Last Update Submit

October 12, 2022

Conditions

Outcome Measures

Primary Outcomes (1)

  • Ability of the relative variation of cardiac output measured by thoracic bio-reactance to predict the patient's status (stable or unstable).

    A patient will be considered unstable if the decrease in the relative variation of cardiac output measured with thermodilution between visit one and one year after visit one is at least 15%. Then, the ability of the relative variation of cardiac output measured by thoracic bio-reactance to predict the patient's status (stable or unstable) will be assessed.

    12 months

Study Arms (1)

Thoracic bio-reactance measurement of cardiac output

Device: Thoracic bio-reactance

Interventions

Cardiac output variation measured by thoracic bio-reactance, between inclusion and one year after hemodynamic evaluation by right cardiac catheterization, to discriminate stable patients from those that degrade.

Thoracic bio-reactance measurement of cardiac output

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodNon-Probability Sample
Study Population

Adult patients with pulmonary hypertension and followed by a Competence Center.

You may qualify if:

  • Aged over 18
  • Presenting pulmonary hypertension (PH) followed by the Competence Center of the Hospices Civils de Lyon
  • Follow-up for pulmonary hypertension groups 1, 4 or 5
  • Of which the cardiac index is ≥ 2,5 L/min/m²
  • Expressing its non-opposition to the participation of this study
  • Benefiting from a social security scheme or similar

You may not qualify if:

  • Adult patient protected by Law
  • Patient for whom a thermodilution measurement of cardiac output (CO) is unreliable: right-left shunt; or uncorrected congenital heart disease; or variability\> 10% of the 3 measurements of CO obtained by thermodilution
  • pulmonary hypertension groups 2 or 3
  • Hemodynamic aggravation since the previous visit: increased pressure or decreased cardiac index

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Service d'Explorations Fonctionnelles Respiratoires, centre de compétences de l'hypertension pulmonaire Hospices Civils de Lyon, Groupement Hospitalier Est

Bron, 69677, France

Location

MeSH Terms

Conditions

Hypertension, Pulmonary

Condition Hierarchy (Ancestors)

Lung DiseasesRespiratory Tract DiseasesHypertensionVascular DiseasesCardiovascular Diseases

Study Design

Study Type
observational
Observational Model
COHORT
Time Perspective
PROSPECTIVE
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

March 25, 2019

First Posted

March 26, 2019

Study Start

May 21, 2019

Primary Completion

May 31, 2022

Study Completion

May 31, 2022

Last Updated

October 13, 2022

Record last verified: 2022-10

Data Sharing

IPD Sharing
Will not share

Locations