Accuracy of the Sensory Test Using the Laryngopharyngeal Endoscopic Esthesiometer in Obstructive Sleep Apnea
Accuracy of the Sensory Test Performed Using the Laryngopharyngeal Endoscopic Esthesiometer and Rangefinder in Patients With Suspected Obstructive Sleep Apnoea Hypopnea (OSA): a Prospective Double-blinded, Randomised, Pilot Study
1 other identifier
interventional
117
1 country
2
Brief Summary
This is a prospective double blinded randomized crossover controlled trial aiming at validating the measurement of laryngopharyngeal mechanosensitivity in patients with suspected OSA using a recently developed laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER). Subjects will be recruited from patients with suspected OSA referred for baseline polysomnography to a university hospital sleep laboratory. Intra- and inter-rater reliability will be evaluated using the Bland-Altman's limits of agreement plot, the intraclass correlation coefficient, and the Pearson or Spearman correlation coefficient, depending on the distribution of the variables. Diagnostic accuracy will be evaluate plotting Receiver-operating-characteristic-curves (ROC-curves) using as reference standard basal polysomnogram. The sensory threshold values for patients with mild, moderate, and severe OSA, will be determined and compared using ANOVA or Kruskal Wallis test, depending on the distribution of the variables.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Jan 2018
Longer than P75 for not_applicable
2 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
April 6, 2017
CompletedFirst Posted
Study publicly available on registry
April 12, 2017
CompletedStudy Start
First participant enrolled
January 1, 2018
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 30, 2026
ExpectedStudy Completion
Last participant's last visit for all outcomes
November 30, 2026
January 8, 2026
January 1, 2026
8.8 years
April 6, 2017
January 6, 2026
Conditions
Keywords
Outcome Measures
Primary Outcomes (3)
Velopharynx psychophysical sensory threshold
Sensitivity threshold at the velopharynx in millinewtons (mN).
15 days
Hypopharynx psychophysical sensory threshold
Sensitivity threshold at the hypopharynx in millinewtons (mN).
15 days
Aryepiglottic fold psychophysical sensory threshold
Sensitivity threshold at the aryepiglottic folds in millinewtons (mN).
15 days
Secondary Outcomes (4)
Apnea Hypopnea Index
15 days
Oxygen desaturation index
15 days
T90
15 days
Adverse Events
15 days
Study Arms (2)
Expert rater
OTHERPulmonologist or Otolaryngologist with experience in laryngopharyngeal sensory evaluation: who has made more than 50 laryngopharyngeal sensory tests.
Non-expert rater
OTHER* Pulmonologist or Otolaryngologist inexperienced in laryngopharyngeal sensory evaluation: who has made minimum 5 and maximum 50 laryngopharyngeal sensory tests. * Pulmonologist fellow who has completed the training provided for a Pulmonologist Fellow in bronchoscopy and who has performed minimum 5 and maximum 50 laryngopharyngeal sensory testing.
Interventions
The sensory measurements will include thresholds for psychophysical sensory thresholds at the velopharynx, hypopharynx and aryepiglottic folds
Eligibility Criteria
You may qualify if:
- Patients being 18 years old or more referred to the sleep laboratory of a tertiary care university hospital for a baseline polysomnography for suspected OSA.
You may not qualify if:
- Bleeding diathesis.
- Basal awake oxygen saturation by pulse oximetry below 88%.
- Not agree to participate in the study.
- Glasgow coma scale below of 15 (to avoid confusion with involvement of laryngopharyngeal reflexes due to neurological disease accompanied by decreased level of consciousness).
- Baseline polysomnography that does not meet validity criteria to be interpreted (according to the American Academy of Sleep Medicine).
- Baseline polysomnography performed more than 15 days before the sensory testing. Ordinarily, the sensory testing will be performed the same day or the next day of baseline polysomnography.
- More than 5% of total apnoea events being of central origin.
- History of maxillofacial or pharyngeal surgery (to avoid confusion with involvement of laryngopharyngeal reflexes due to surgery in this region).
- Laryngopharyngeal tract malignancies (to avoid confusion with involvement of laryngopharyngeal reflexes due to tumours).
- Central Nervous System (CNS) surgery in the last three months or that has left neurological sequelae (to avoid confusion with involvement of laryngopharyngeal reflexes due to sequelae of CNS surgery).
- Traumatic brain injury in the last three months or more than three month with neurological sequelae.
- History of active neuromuscular disease that affects the muscles of head and neck or with sequels present at the time of the sensory testing (to avoid confusion with involvement of laryngopharyngeal reflexes due to neuromuscular disease).
- History of cerebrovascular disease (to avoid confusion with dysphagia or sensory compromise secondary to cerebrovascular disease).
- Diabetes (to avoid confusion with diabetic neuropathy that compromises the laryngopharyngeal region).
- Chronic use of systemic corticosteroids at a dose greater or equal to 20 mg per day of prednisone or equivalent (to avoid confusion with steroid myopathy that compromises the laryngopharyngeal region).
- +2 more criteria
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (2)
Fundacion Neumologica Colombiana
Bogotá, Bogota D.C., 110131399, Colombia
Universidad de la Sabana
Chía, Cundinamarca, 250001, Colombia
Related Publications (28)
Miyaji H, Hironaga N, Umezaki T, Hagiwara K, Shigeto H, Sawatsubashi M, Tobimatsu S, Komune S. Neuromagnetic detection of the laryngeal area: Sensory-evoked fields to air-puff stimulation. Neuroimage. 2014 Mar;88:162-9. doi: 10.1016/j.neuroimage.2013.11.008. Epub 2013 Nov 15.
PMID: 24246493BACKGROUNDNguyen AT, Jobin V, Payne R, Beauregard J, Naor N, Kimoff RJ. Laryngeal and velopharyngeal sensory impairment in obstructive sleep apnea. Sleep. 2005 May;28(5):585-93. doi: 10.1093/sleep/28.5.585.
PMID: 16171271BACKGROUNDAviv JE, Martin JH, Sacco RL, Zagar D, Diamond B, Keen MS, Blitzer A. Supraglottic and pharyngeal sensory abnormalities in stroke patients with dysphagia. Ann Otol Rhinol Laryngol. 1996 Feb;105(2):92-7. doi: 10.1177/000348949610500202.
PMID: 8659942BACKGROUNDAviv JE, Sacco RL, Mohr JP, Thompson JL, Levin B, Sunshine S, Thomson J, Close LG. Laryngopharyngeal sensory testing with modified barium swallow as predictors of aspiration pneumonia after stroke. Laryngoscope. 1997 Sep;107(9):1254-60. doi: 10.1097/00005537-199709000-00018.
PMID: 9292613BACKGROUNDJordan AS, McSharry DG, Malhotra A. Adult obstructive sleep apnoea. Lancet. 2014 Feb 22;383(9918):736-47. doi: 10.1016/S0140-6736(13)60734-5. Epub 2013 Aug 2.
PMID: 23910433BACKGROUNDTeramoto S, Sudo E, Matsuse T, Ohga E, Ishii T, Ouchi Y, Fukuchi Y. Impaired swallowing reflex in patients with obstructive sleep apnea syndrome. Chest. 1999 Jul;116(1):17-21. doi: 10.1378/chest.116.1.17.
PMID: 10424498BACKGROUNDValbuza JS, de Oliveira MM, Zancanella E, Conti CF, Prado LB, Carvalho LB, do Prado GF. Swallowing dysfunction related to obstructive sleep apnea: a nasal fibroscopy pilot study. Sleep Breath. 2011 May;15(2):209-13. doi: 10.1007/s11325-010-0474-9. Epub 2011 Jan 13.
PMID: 21229321BACKGROUNDGiraldo-Cadavid LF, Burguete J, Rueda F, Galvis AM, Castaneda N, Agudelo-Otalora LM, Moscoso WD, Paez N, Fernandez S. Reliability of a laryngo-pharyngeal esthesiometer and a method for measuring laryngo-pharyngeal mechano-sensitivity in a prospectively recruited cohort of patients. Eur Arch Otorhinolaryngol. 2017 Jul;274(7):2861-2870. doi: 10.1007/s00405-017-4536-5. Epub 2017 Mar 24.
PMID: 28341965BACKGROUNDGiraldo-Cadavid LF, Agudelo-Otalora LM, Burguete J, Arbulu M, Moscoso WD, Martinez F, Ortiz AF, Diaz J, Pantoja JA, Rueda-Arango AF, Fernandez S. Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants. Biomed Eng Online. 2016 May 10;15(1):52. doi: 10.1186/s12938-016-0166-1.
PMID: 27160751BACKGROUNDOliveira LA, Fontes LH, Cahali MB. Swallowing and pharyngo-esophageal manometry in obstructive sleep apnea. Braz J Otorhinolaryngol. 2015 May-Jun;81(3):294-300. doi: 10.1016/j.bjorl.2015.03.006. Epub 2015 Mar 30.
PMID: 25921934BACKGROUNDChien MY, Wu YT, Lee PL, Chang YJ, Yang PC. Inspiratory muscle dysfunction in patients with severe obstructive sleep apnoea. Eur Respir J. 2010 Feb;35(2):373-80. doi: 10.1183/09031936.00190208. Epub 2009 Jul 30.
PMID: 19643936BACKGROUNDTsai YJ, Ramar K, Liang YJ, Chiu PH, Powell N, Chi CY, Lung TC, Wen-Yang Lin W, Tseng PJ, Wu MY, Chien KC, Weaver EM, Lee FP, Lin CM, Chen KC, Chiang RP. Peripheral neuropathology of the upper airway in obstructive sleep apnea syndrome. Sleep Med Rev. 2013 Apr;17(2):161-8. doi: 10.1016/j.smrv.2012.05.005. Epub 2012 Aug 17.
PMID: 22902356BACKGROUNDEckert DJ, Lo YL, Saboisky JP, Jordan AS, White DP, Malhotra A. Sensorimotor function of the upper-airway muscles and respiratory sensory processing in untreated obstructive sleep apnea. J Appl Physiol (1985). 2011 Dec;111(6):1644-53. doi: 10.1152/japplphysiol.00653.2011. Epub 2011 Sep 1.
PMID: 21885797BACKGROUNDFogel RB, Malhotra A, Shea SA, Edwards JK, White DP. Reduced genioglossal activity with upper airway anesthesia in awake patients with OSA. J Appl Physiol (1985). 2000 Apr;88(4):1346-54. doi: 10.1152/jappl.2000.88.4.1346.
PMID: 10749829BACKGROUNDKezirian EJ, Boudewyns A, Eisele DW, Schwartz AR, Smith PL, Van de Heyning PH, De Backer WA. Electrical stimulation of the hypoglossal nerve in the treatment of obstructive sleep apnea. Sleep Med Rev. 2010 Oct;14(5):299-305. doi: 10.1016/j.smrv.2009.10.009. Epub 2010 Jan 29.
PMID: 20116305BACKGROUNDGillick BT, Zirpel L. Neuroplasticity: an appreciation from synapse to system. Arch Phys Med Rehabil. 2012 Oct;93(10):1846-55. doi: 10.1016/j.apmr.2012.04.026. Epub 2012 May 18.
PMID: 22613094BACKGROUNDPage SJ, Cunningham DA, Plow E, Blazak B. It takes two: noninvasive brain stimulation combined with neurorehabilitation. Arch Phys Med Rehabil. 2015 Apr;96(4 Suppl):S89-93. doi: 10.1016/j.apmr.2014.09.019.
PMID: 25813373BACKGROUNDRobbins SM, Houghton PE, Woodbury MG, Brown JL. The therapeutic effect of functional and transcutaneous electric stimulation on improving gait speed in stroke patients: a meta-analysis. Arch Phys Med Rehabil. 2006 Jun;87(6):853-9. doi: 10.1016/j.apmr.2006.02.026.
PMID: 16731222BACKGROUNDHowlett OA, Lannin NA, Ada L, McKinstry C. Functional electrical stimulation improves activity after stroke: a systematic review with meta-analysis. Arch Phys Med Rehabil. 2015 May;96(5):934-43. doi: 10.1016/j.apmr.2015.01.013. Epub 2015 Jan 26.
PMID: 25634620BACKGROUNDGallas S, Marie JP, Leroi AM, Verin E. Sensory transcutaneous electrical stimulation improves post-stroke dysphagic patients. Dysphagia. 2010 Dec;25(4):291-7. doi: 10.1007/s00455-009-9259-3. Epub 2009 Oct 24.
PMID: 19856025BACKGROUNDRofes L, Arreola V, Lopez I, Martin A, Sebastian M, Ciurana A, Clave P. Effect of surface sensory and motor electrical stimulation on chronic poststroke oropharyngeal dysfunction. Neurogastroenterol Motil. 2013 Nov;25(11):888-e701. doi: 10.1111/nmo.12211. Epub 2013 Aug 12.
PMID: 23937476BACKGROUNDAviv JE, Martin JH, Keen MS, Debell M, Blitzer A. Air pulse quantification of supraglottic and pharyngeal sensation: a new technique. Ann Otol Rhinol Laryngol. 1993 Oct;102(10):777-80. doi: 10.1177/000348949310201007.
PMID: 8215097BACKGROUNDCunningham JJ, Halum SL, Butler SG, Postma GN. Intraobserver and interobserver reliability in laryngopharyngeal sensory discrimination thresholds: a pilot study. Ann Otol Rhinol Laryngol. 2007 Aug;116(8):582-8. doi: 10.1177/000348940711600805.
PMID: 17847725BACKGROUNDHammer MJ. Design of a new somatosensory stimulus delivery device for measuring laryngeal mechanosensory detection thresholds in humans. IEEE Trans Biomed Eng. 2009 Apr;56(4):1154-9. doi: 10.1109/TBME.2008.2007968. Epub 2008 Oct 31.
PMID: 19272888BACKGROUNDLarsson H, Carlsson-Nordlander B, Lindblad LE, Norbeck O, Svanborg E. Temperature thresholds in the oropharynx of patients with obstructive sleep apnea syndrome. Am Rev Respir Dis. 1992 Nov;146(5 Pt 1):1246-9. doi: 10.1164/ajrccm/146.5_Pt_1.1246.
PMID: 1443879BACKGROUNDKimoff RJ, Sforza E, Champagne V, Ofiara L, Gendron D. Upper airway sensation in snoring and obstructive sleep apnea. Am J Respir Crit Care Med. 2001 Jul 15;164(2):250-5. doi: 10.1164/ajrccm.164.2.2010012.
PMID: 11463596BACKGROUNDAviv JE, Murry T, Zschommler A, Cohen M, Gartner C. Flexible endoscopic evaluation of swallowing with sensory testing: patient characteristics and analysis of safety in 1,340 consecutive examinations. Ann Otol Rhinol Laryngol. 2005 Mar;114(3):173-6. doi: 10.1177/000348940511400301.
PMID: 15825564BACKGROUNDGiraldo-Cadavid LF, Bastidas AR, Padilla-Ortiz DM, Concha-Galan DC, Bazurto MA, Vargas L. Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study. BMJ Open. 2017 Aug 21;7(8):e015235. doi: 10.1136/bmjopen-2016-015235.
PMID: 28827237DERIVED
Related Links
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- STUDY CHAIR
Luis F Giraldo-Cadavid, MD, PhD
University of La Sabana; Fundacion Neumologica Colombiana
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- QUADRUPLE
- Who Masked
- PARTICIPANT, CARE PROVIDER, INVESTIGATOR, OUTCOMES ASSESSOR
- Masking Details
- The allocation sequence, determining which rater (expert vs non-expert) intervenes first or second, will be concealed using the SNOSE strategy (sequentially numbered opaque sealed envelopes). One of the authors (ARB), who has not competing interests will generate the allocation sequence and conceal it in envelopes. While the first rater measures the sensory thresholds (ST) the second rater will be at a different room for blinding purposes. There will be no communication about the testing results between the two raters nor the staff who are helping the testing performance. To mask the values of the ST, air pulses will be identified by a random combination of three letters instead of by the intensity levels corresponding to the air pulses. The raters will not know the intensity corresponding to each letter combination. At the end of the test, an assistant will replace the letters corresponding to the ST values by the intensity levels of the air pulses in units of force (millinewtons)
- Purpose
- DIAGNOSTIC
- Intervention Model
- CROSSOVER
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Pulmonologist
Study Record Dates
First Submitted
April 6, 2017
First Posted
April 12, 2017
Study Start
January 1, 2018
Primary Completion (Estimated)
September 30, 2026
Study Completion (Estimated)
November 30, 2026
Last Updated
January 8, 2026
Record last verified: 2026-01
Data Sharing
- IPD Sharing
- Will not share