Effect of Sleep Disruption on the Outcome of Weaning From Mechanical Ventilation
SLEEWE
1 other identifier
observational
44
1 country
3
Brief Summary
Mechanically ventilated patients in the Intensive Care Unit (ICU) are highly susceptible to sleep disruption. Several studies in the last 15 years have demonstrated an extremely poor sleep quality and abnormal sleep pattern evaluated by polysomnography (PSG) devices (the gold standard method for evaluating sleep quality and quantity). Discontinuation of mechanical ventilation should be considered as soon as possible when a patient's condition starts to improve. A patient's ability to be weaned from the mechanical ventilator can be assessed using two step approaches including a Rapid Shallow Breathing Index (RSBI) calculation then a spontaneous breathing trial (SBT) to determine the likelihood of success or failure before considering endotracheal extubation. The rate of weaning failure from the first SBT attempt has been reported to be 35-55%. The reason for weaning failure may be complex and multifactorial. An association between sleep disruption and weaning outcome has never been studied. The goal of this study is to look for an association between poor sleep quality and failure of a weaning attempt. This study is an observational, physiological study investigating sleep quality and quantity in patients who will be weaned by recording standard PSG (from 17:00 to 08:00) at night before a weaning attempt. Sleep characteristics of patients failing or passing the weaning attempt will be compared. In addition, we will compare sleep patterns before and after endotracheal extubation.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Jan 2016
3 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
May 28, 2015
CompletedFirst Posted
Study publicly available on registry
June 8, 2015
CompletedStudy Start
First participant enrolled
January 1, 2016
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 1, 2017
CompletedStudy Completion
Last participant's last visit for all outcomes
September 1, 2017
CompletedApril 12, 2018
April 1, 2018
1.7 years
May 28, 2015
April 11, 2018
Conditions
Keywords
Outcome Measures
Primary Outcomes (2)
Comparison of sleep quality between patients who pass weaning and patients who fail a weaning assessment
15 hours
Comparison of sleep quality (sleep efficiency and fragmentation) the night before a patient fails weaning and the night after they eventually pass weaning
30 hours
Secondary Outcomes (5)
Comparison between patients who pass and patients who fail weaning in terms of % of rapid eye movement sleep, sleep quantity (or efficiency), slow wave sleep and circadian sleep ratio, % of "pathological/atypical" sleep patterns, and sleep continuity
15 hours
Comparison of sleep architecture (total sleep time, % of NREM and REM sleep) the night before weaning and the night of extubation
30 hours
Incidence of delirium amongst all patient groups, regardless of the outcome of weaning
Up to 14 days
Analysis of the validity of the odds ratio product (ORP) technique for classification of sleep depth in comparison to standard PSG criteria by American Academy of Sleep Medicine (AASM).
Up to 14 days
Correlation between sleep disruption and delirium.
Up to 14 days
Interventions
Eligibility Criteria
Mechanically ventilated Intensive Care Unit patients who have a spontaneous breathing trial planned for the next day.
You may qualify if:
- Age \> 16 years
- Intubated and mechanically ventilated
- A spontaneous breathing trial (SBT) is planned for the next day; patients can be enrolled if they have already had previous SBTs
You may not qualify if:
- Presence of recent major central nervous system disease impairing consciousness with Glasgow Coma Scale ≤ 8T
- Patients with a sleep breathing disorder when it is predominantly central sleep apnea; patients with predominantly obstructive sleep apnea can be included
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (3)
St. Michael's Hospital
Toronto, Ontario, M5B 1W8, Canada
Mount Sinai Hospital
Toronto, Ontario, M5G 1X5, Canada
Toronto Western Hospital
Toronto, Ontario, M5T 2S8, Canada
Related Publications (4)
Drouot X, Cabello B, d'Ortho MP, Brochard L. Sleep in the intensive care unit. Sleep Med Rev. 2008 Oct;12(5):391-403. doi: 10.1016/j.smrv.2007.11.004. Epub 2008 May 23.
PMID: 18502155BACKGROUNDRoche Campo F, Drouot X, Thille AW, Galia F, Cabello B, d'Ortho MP, Brochard L. Poor sleep quality is associated with late noninvasive ventilation failure in patients with acute hypercapnic respiratory failure. Crit Care Med. 2010 Feb;38(2):477-85. doi: 10.1097/CCM.0b013e3181bc8243.
PMID: 19789439BACKGROUNDTobin MJ. Extubation and the myth of "minimal ventilator settings". Am J Respir Crit Care Med. 2012 Feb 15;185(4):349-50. doi: 10.1164/rccm.201201-0050ED. No abstract available.
PMID: 22336673BACKGROUNDBoles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, Pearl R, Silverman H, Stanchina M, Vieillard-Baron A, Welte T. Weaning from mechanical ventilation. Eur Respir J. 2007 May;29(5):1033-56. doi: 10.1183/09031936.00010206.
PMID: 17470624BACKGROUND
MeSH Terms
Conditions
Interventions
Condition Hierarchy (Ancestors)
Intervention Hierarchy (Ancestors)
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
May 28, 2015
First Posted
June 8, 2015
Study Start
January 1, 2016
Primary Completion
September 1, 2017
Study Completion
September 1, 2017
Last Updated
April 12, 2018
Record last verified: 2018-04