Brief Summary
Cardiac resynchronisation therapy (CRT) using biventricular pacing (BiVP) is established as an effective treatment for heart failure. Unfortunately up to 45% of patients do not respond, with no improvement in symptoms or cardiac size. Reducing the proportion of non-responders has become the key research focus in CRT. Targeting the position of the left ventricular (LV) pacing lead within the coronary vein network has previously been shown to increase the proportion of responders to CRT. Several techniques have been tried for targeting lead position, of which the best investigated are the use of speckle-tracking echocardiography to target the lead position to the site of latest mechanical activation of the left ventricle, and the use of invasive monitoring to select the pacing site at which the greatest acute haemodynamic response (AHR) to BiVP occurs. Both techniques are limited by groups of patients in whom the techniques are not possible or provide limited useful information. The relationship between these two measures is unknown - there are no previous studies that have investigated correlation between the site of latest mechanical activation determined by echo and the site of maximal AHR. It is likely that a hybrid technique using both of these investigations might allow optimal lead positioning in more patients, or that if the information is shown to be equivalent, more streamlined techniques can be designed. This study will also be able to contribute towards several important secondary questions. In particular the investigators will study the possibility of using non-invasive cardiac output monitoring (NICOM) to assess haemodynamic response rather than an intravascular pressure monitor wire. The investigators also wish to assess whether the site of latest mechanical activation is changed by right ventricular pacing.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for all trials
Started Apr 2014
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 7, 2014
CompletedFirst Posted
Study publicly available on registry
February 12, 2014
CompletedStudy Start
First participant enrolled
April 1, 2014
CompletedPrimary Completion
Last participant's last visit for primary outcome
March 1, 2015
CompletedStudy Completion
Last participant's last visit for all outcomes
October 1, 2015
CompletedOctober 20, 2015
October 1, 2015
11 months
February 7, 2014
October 16, 2015
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Acute haemodynamic response in area of latest mechanical activation and another vein
To assess whether pacing at the site of latest mechanical activation produces the maximal acute haemodynamic response to biventricular pacing, when compared to other attainable Left Ventricular coronary venous pacing sites. Acute haemodynamic response measured as percentage change in left ventricular dP/dt max (maximum rate of change of left ventricular pressure) recorded by a left ventricular pressure wire, between baseline atrial pacing at 80 beats per minute and biventricular pacing in each vein
Time 0 (during implant procedure)
Secondary Outcomes (3)
Maximum acute haemodynamic response between all available pacing vectors in the vein within the area of latest mechanical response
Time 0 (during implant procedure)
Acute haemodynamic response by NICOM and pressure wire
Time 0 (during implant procedure)
Area of latest mechanical activation in right ventricular pacing and intrinsic rhythm
1 day post procedure
Study Arms (1)
Patients
All included patients, having CRT implant procedure Will have both Pacing in vein at site of latest mechanical activation and Pacing in other suitable vein.
Interventions
Pacing in vein at site of latest mechanical activation
Eligibility Criteria
Due to have CRT device implants.
You may qualify if:
- With ejection fraction \<35%
- Participant is willing and able to give informed consent for participation in the study.
- Male or Female, aged 18 years or above.
- Indication for cardiac resynchronisation therapy
You may not qualify if:
- Left Ventricular Ejection Fraction \>35%
- Severe peripheral vascular disease (that would make arterial access more risky)
- Haemodynamic instability (such that a longer procedure is inadvisable)
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Oxford University Hospitals NHS Trust
Oxford, Oxfordshire, OX3 7AT, United Kingdom
Related Publications (4)
Khan FZ, Virdee MS, Palmer CR, Pugh PJ, O'Halloran D, Elsik M, Read PA, Begley D, Fynn SP, Dutka DP. Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial. J Am Coll Cardiol. 2012 Apr 24;59(17):1509-18. doi: 10.1016/j.jacc.2011.12.030. Epub 2012 Mar 7.
PMID: 22405632BACKGROUNDMcAlister FA, Ezekowitz J, Hooton N, Vandermeer B, Spooner C, Dryden DM, Page RL, Hlatky MA, Rowe BH. Cardiac resynchronization therapy for patients with left ventricular systolic dysfunction: a systematic review. JAMA. 2007 Jun 13;297(22):2502-14. doi: 10.1001/jama.297.22.2502.
PMID: 17565085BACKGROUNDSaba S, Marek J, Schwartzman D, Jain S, Adelstein E, White P, Oyenuga OA, Onishi T, Soman P, Gorcsan J 3rd. Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial. Circ Heart Fail. 2013 May;6(3):427-34. doi: 10.1161/CIRCHEARTFAILURE.112.000078. Epub 2013 Mar 8.
PMID: 23476053BACKGROUNDDuckett SG, Ginks M, Shetty AK, Bostock J, Gill JS, Hamid S, Kapetanakis S, Cunliffe E, Razavi R, Carr-White G, Rinaldi CA. Invasive acute hemodynamic response to guide left ventricular lead implantation predicts chronic remodeling in patients undergoing cardiac resynchronization therapy. J Am Coll Cardiol. 2011 Sep 6;58(11):1128-36. doi: 10.1016/j.jacc.2011.04.042.
PMID: 21884950BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Tim R Betts, MBChB, MD
Oxford University Hospitals
Study Design
- Study Type
- observational
- Observational Model
- CASE ONLY
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Co-investigator
Study Record Dates
First Submitted
February 7, 2014
First Posted
February 12, 2014
Study Start
April 1, 2014
Primary Completion
March 1, 2015
Study Completion
October 1, 2015
Last Updated
October 20, 2015
Record last verified: 2015-10