One of the contributing factors to the variability in outcomes amongst Cochlear Implant (CI) recipients was reported to be the placement of the electrode array in the scala tympani. It seems that the correct placement of the electrode initially into the scala tympani and subsequent avoidance of dislocation into the scala vestibuli as the insertion progresses, is a key factor in achieving good speech perception outcomes. Another important aspect related to the performance is the achievement of consistent electrical coverage with the electrode. Data reported for electrodes of different manufacturers give depths ranging from 240 - 600 degrees showing the considerable variation across subjects. The HiFocus mid scala electrode was developed to cover one and a quarter turn and with the pre-curved design to be less susceptible to variations in individual cochlea dimensions and insertion techniques. A further mechanical feature of the pre-curved design is the avoidance of forces against the cochlear lateral wall and associated lower susceptibility of the electrode for moving out of the cochlea following insertion. Recently, a cone beam CT (CBCT) technique is being explored in the field of ENT with the potential to overcome some of the issues associated with the conventional CT techniques such as scattering, radiation and low isometric resolution. Images with comparable details to those of e.g. micro CTs are possible with much lower radiation dose. Modern imaging software i.e. 3D Slicer (www.slicer.org) may be used for 3D reconstruction, post processing and Brainsfit for registration. Registration is the alignment of two scans in the same coordinate system. This enables the identification of differences between two images recorded at time x and y. Once accurately superimposed any difference between the two images may be identified with an accuracy of 0.2 mm. Using these methods, one can assess the stability and the position of the electrode in the cochlea. Objective: The primary objectives of this study are to evaluate the feasibility of using cone beam CT technique in combination with (high resolution) MRI to identify electrode movements following cochlear implant surgery and identify the inter-scalar position of the HFms electrode. The secondary objective is to quantify the average insertion depth and variations of the HFms electrode
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Sep 2013
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
September 1, 2013
CompletedFirst Submitted
Initial submission to the registry
September 9, 2013
CompletedFirst Posted
Study publicly available on registry
September 12, 2013
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 1, 2014
CompletedStudy Completion
Last participant's last visit for all outcomes
September 1, 2014
CompletedSeptember 12, 2013
September 1, 2013
1 year
September 9, 2013
September 11, 2013
Conditions
Outcome Measures
Primary Outcomes (1)
movement of the electrode post-operatively in millimetres
3 months
Study Arms (1)
Intervention
OTHERAll participants in the study will receive one pre-operative MRI, prior to cochlear implantation, and two cone-beam computed tomography scans, after cochlear implantation
Interventions
Two postoperative CBCT scans, the first one on the day after cochlear implantation and the second after 3 months.
One pre-operative (before cochlear implantation) MRI scan of the cochlea.
Eligibility Criteria
You may qualify if:
- Adults 18y or older meeting the conventional Dutch CI criteria
- The patient will receives the HiFocus Mid Scala electrode
- No cochlear or neural abnormalities that could compromise the placement of the electrode as assessed by the CI surgeon
You may not qualify if:
- Physical or non-physical contraindications for MRI or CT imaging
- No additional disabilities that may prevent active participation and testing as per protocol
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Maastricht University Medical Centerlead
- Advanced Bionicscollaborator
Study Sites (1)
Maastricht University Medical Center
Maastricht, Limburg, 6202 AZ, Netherlands
MeSH Terms
Interventions
Intervention Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Robert Stokroos, MD PhD
Maastricht University Medical Center
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- DIAGNOSTIC
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- MD, MSc
Study Record Dates
First Submitted
September 9, 2013
First Posted
September 12, 2013
Study Start
September 1, 2013
Primary Completion
September 1, 2014
Study Completion
September 1, 2014
Last Updated
September 12, 2013
Record last verified: 2013-09