NCT01012583

Brief Summary

BACKGROUND Treatment of coronary atherosclerotic disease has been significantly advanced by interventional cardiology, and the advent of coronary arterial stents. In comparison to angioplasty alone, stents have reduced the incidence of angiographic as well as clinical restenosis, the recurrence of angina, the need for coronary arterial bypass graft (CABG) surgery, repeat revascularization and the occurrence of major adverse cardiac events (MACE).However the long-term success of this therapy has been limited by the occurrence of in-stent restenosis. Despite the effectiveness of intracoronary stents in maintaining a larger luminal diameter, as compared to angioplasty alone, in-stent restenosis occurs within 6 to 9 months after stent placement in 15% to 35% of patients. While stents can reduce restenosis by blocking vascular recoil and remodeling, mechanical intervention alone has been incapable of treating this biological problem of neointimal hyperplasia, particularly in the subset of patients with diabetes, long lesions or small vessel disease.Drug-eluting stents (DES) were developed as a viable method for focused delivery of anti-restenosis compounds to target lesions for the reduction of restenosis. Of the DES available and with the results of up to six (6) years clinical follow-up, the sirolimus-eluting stent (SES) has become the current gold standard for stent implantation. With the advent of using DES to treat complex lesions such as longer lesions requiring the use of multiple stents and the use in bifurcation lesions, the risk of stent thrombosis has increase.Late stent thrombosis has also been reported following DES implantation.Long term treatment with dual anti-platelet therapy following stent implantation has become the solution used to counteract the risk of stent thrombosis, this solution does not come without it's own risks and is an expensive therapy. Another specific problem of DES is delayed endothelization, and this may be and attributing factor in prolonging the period of thrombotic risk as shown by pathological findings at autopsy following SES implantation. These examinations have shown that even after 16 months, neointimal healing is still incomplete with approximately 20% of stent struts being found uncovered. Questions have arose that the problems of late thrombosis and delayed endothelization of stent struts with DES could be the result of the permanent polymer that is used as the bonding agent for the anti-restenosis compounds to the stents.Intravascular Ultrasound (IVUS) along with angiography has been the techniques used to gain data on DES to this point. Angiography is a 2 dimensional tool that gives a view of the vessel and IVUS gives a more 3 dimensional view of the vessel. IVUS does have its limitations, as stent struts are reflectors of sonic waves, shadowing around and behind the struts occurs. IVUS is also limited in detecting malapposition of the struts to the vessel wall especially if the area between the vessel wall and the strut in very small. RATIONALE Optical Coherence Tomography (OCT) is an optical analogue of IVUS that uses an infrared light source and measures the backscatter of the light. With this technique a higher level of resolution compared with IVUS has been reported.OCT has been reported as being able to visualize and detect atherosclerotic plaques and assess more accurately strut malapposition and the presence or thickness of neointimal hyperplasia as compared to IVUS. With the question of delayed endothelization due to the permanent polymer being a probable risk for late stent thrombosis, it is felt that OCT post stent implantation may give a more accurate assessment of stent strut endothelial coverage. This study is designed to compare the intimal hyperplasia following implantation of the Excel DES with a biodegradable polymer vs. the Cypher DES with a permanent polymer using OCT.

Trial Health

35
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Enrollment
1

participants targeted

Target at below P25 for all trials

Timeline
Completed

Started Nov 2009

Shorter than P25 for all trials

Status
unknown

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

November 1, 2009

Completed
11 days until next milestone

First Submitted

Initial submission to the registry

November 12, 2009

Completed
1 day until next milestone

First Posted

Study publicly available on registry

November 13, 2009

Completed
11 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

October 1, 2010

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

October 1, 2010

Completed
Last Updated

November 13, 2009

Status Verified

November 1, 2009

Enrollment Period

11 months

First QC Date

November 12, 2009

Last Update Submit

November 12, 2009

Conditions

Keywords

Optical coherence tomographyDrug eluting stentBiodegradable polymerIntimalCoverageassess intimal hyperplasia of drug eluting stent with biodegradable polymer

Outcome Measures

Primary Outcomes (1)

  • To quantitate the presence of neointimal stent strut coverage at 6 month via Optical Coherence Tomography follow-up.

    6 month

Secondary Outcomes (1)

  • 1.Stent strut apposition at 6 month follow-up. 2. Neointimal thickness at 6 month follow-up. 3. late loss at 6 months 4. Major Adverse Cardiac Events

    12 month

Eligibility Criteria

Age18 Years - 75 Years
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodProbability Sample
Study Population

This study intends to enroll up to 100 patients from a single center in China. Patients will be randomized in a 1:1 fashion, Excel DES:Cypher DES.

You may qualify if:

  • Age between 30 and 75 years.
  • Binary stenosis of \> 70% in a de novo lesion in native coronary artery.
  • Reference lumen diameter proximal to the target lesion is 2.5 mm and \< 4.0 mm.
  • Reference lesion length of \< 30 mm.
  • The target lesioin can be covered with a makimum of two overlapping stents at a single lesion.
  • Written informed consent has been signed.

You may not qualify if:

  • Pregnant or breast feeding woman.
  • Intolerance to aspirin, clopidogrel (Plavix®), ticlopidine(Ticlid®), heparin, bivalirudin, stainless steel, contrast agent(that cannot be adequately premedicated), parylene, poly-lacticacid (PLA), or Biolimus A9 (or its analogues).
  • Lesion located in a protected or unprotected Left Main Coronary Artery.
  • STEMI within 72 hours prior to index procedure.
  • The patient has had another drug-eluting stent (DES) implanted within 12 months prior to the index procedure.
  • CCS Class III patients or the patient has a LVEF of \< 40%.
  • Diffuse lesions of \> 40 mm in length.
  • Renal impairment, with a serum creatinine of \> 2.0 mg/dl.
  • Complicated anatomy such as Chronic Total Occlusion (CTO),Bifurcation Lesions (with side branch of \> 2.5 mm) or Triple Vessel Disease (TVD).
  • Lesion cannot be pre-dilated successfully.
  • History of gastritis and/or bleeding history which will limit the usual dual anti-platelet regime.
  • Patient has a co-morbid condition(s) that could limit his/her ability to participate in the study, comply with follow-up requirements and impact the scientific integrity of the study.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

MeSH Terms

Conditions

Atherosclerosis

Condition Hierarchy (Ancestors)

ArteriosclerosisArterial Occlusive DiseasesVascular DiseasesCardiovascular Diseases

Study Design

Study Type
observational
Observational Model
CASE CONTROL
Time Perspective
PROSPECTIVE
Sponsor Type
OTHER

Study Record Dates

First Submitted

November 12, 2009

First Posted

November 13, 2009

Study Start

November 1, 2009

Primary Completion

October 1, 2010

Study Completion

October 1, 2010

Last Updated

November 13, 2009

Record last verified: 2009-11