NCT07677241

Brief Summary

Gas exchange measurement systems are complex and require specialized facilities and expertise. As a result, access to these measurements remains limited, particularly in the field of sports performance. The aim of this validation study was to compare measurements obtained with a reference device and a new portable system.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
20

participants targeted

Target at below P25 for all trials

Timeline
Completed

Started Jul 2026

Shorter than P25 for all trials

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

June 15, 2026

Completed
15 days until next milestone

First Posted

Study publicly available on registry

June 30, 2026

Completed
6 days until next milestone

Study Start

First participant enrolled

July 6, 2026

Completed
22 days until next milestone

Primary Completion

Last participant's last visit for primary outcome

July 28, 2026

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

July 28, 2026

Completed
Last Updated

August 3, 2026

Status Verified

July 1, 2026

Enrollment Period

22 days

First QC Date

June 15, 2026

Last Update Submit

July 31, 2026

Conditions

Keywords

exerciseventilatory measurement

Outcome Measures

Primary Outcomes (1)

  • Comparison of ventilatory flow (VE) and carbon dioxide output (VCO₂) measurements obtained using the two systems.

    Equivalence of measurements within a 5% margin of error.

    During the 5-minute rest period and throughout the exercise test until exhaustion. 30 minutes total.

Interventions

ZoneXDEVICE

The ZoneX device was developed by PAIRFS. It is a system designed to measure changes in expired volume and fluctuations in the fractional concentration of carbon dioxide in exhaled air (FeCO₂) in healthy volunteers. These data are transmitted in real time via Bluetooth Low Energy (BLE) to dedicated PC software for acquisition and analysis. The device is CE-marked, demonstrating compliance with applicable European regulatory requirements (certificate of conformity provided in the appendix).

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersYes
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodProbability Sample
Study Population

Healthy people from sports team

You may qualify if:

  • Male or female adults (aged ≥ 18 years).
  • Individuals affiliated with, or benefiting from, a health insurance or social security scheme.
  • Individuals capable of understanding and signing an informed consent form.
  • Individuals fluent in French.

You may not qualify if:

  • Current tobacco smoking.
  • Any cardiovascular, respiratory, or musculoskeletal condition that could impair the ability to perform a maximal exercise test.
  • Individuals unwilling or unable to provide written informed consent.
  • Individuals with hierarchical, family, or close personal relationships with the principal investigator.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

CHUGA

Grenoble, 38000, France

Location

MeSH Terms

Conditions

Motor Activity

Condition Hierarchy (Ancestors)

Behavior

Study Officials

  • stephane DOUTRELEAU, MD, PhD

    University Grenoble Alps

    PRINCIPAL INVESTIGATOR

Study Design

Study Type
observational
Observational Model
CASE CONTROL
Time Perspective
PROSPECTIVE
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

June 15, 2026

First Posted

June 30, 2026

Study Start

July 6, 2026

Primary Completion

July 28, 2026

Study Completion

July 28, 2026

Last Updated

August 3, 2026

Record last verified: 2026-07

Locations