NCT07449598

Brief Summary

aim of the study: to evaluate and compare the surface roughness (Ra, Rq, Rz), Vickers microhardness (VHN), and thickness of single-layer and multi-layer clear aligner sheets. material and methods: the study will be conducted on clear aligners fabricated from two commercial thermoplastic materials: single-layer (0.76 mm, ) and multi-layer (0.76 mm, ). Each material will be evaluated at three stages: before thermoforming, after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear. Specimen Preparation For each group, specimens will be prepared at three stages: before thermoforming (T0), after thermoforming (T1), and after intraoral wear (T2). At T0, square-shaped specimens (approximately 5 × 5 mm) will be cut directly from the unused raw sheets. At T1 and T2, specimens of the same dimensions will be obtained from the mid-labial surface of the central incisor region of the thermoformed aligners, both immediately after thermoforming and after two weeks of intraoral wear. The full thickness of the material will be preserved in all specimens to ensure consistency across groups. Outcomes: Primary Outcome: Surface Roughness (Ra): Measured at three stages: T0: Raw, unused sheet specimens (baseline) T1: After thermoforming on dental casts T2: After 2 weeks of intraoral use Secondary Outcomes: Hardness: Measured at T0, T1, and T2. Tested using Vickers hardness method (ISO 6507 compliant).

Trial Health

75
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
20

participants targeted

Target at below P25 for not_applicable

Timeline
7mo left

Started Jan 2026

Geographic Reach
1 country

1 active site

Status
active not recruiting

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Progress42%
Jan 2026Feb 2027

Study Start

First participant enrolled

January 1, 2026

Completed
2 months until next milestone

First Submitted

Initial submission to the registry

February 15, 2026

Completed
17 days until next milestone

First Posted

Study publicly available on registry

March 4, 2026

Completed
10 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

January 1, 2027

Expected
1 month until next milestone

Study Completion

Last participant's last visit for all outcomes

February 1, 2027

Last Updated

March 4, 2026

Status Verified

December 1, 2025

Enrollment Period

1 year

First QC Date

February 15, 2026

Last Update Submit

March 3, 2026

Conditions

Outcome Measures

Primary Outcomes (1)

  • surface roughness of clear aligner

    evaluate and compare the surface roughness of single-layer and multi-layer clear aligner sheets at three stages: before thermoforming, after thermoforming, and following intraoral wear. Quantitative evaluation of the arithmetic mean surface roughness (Ra) using profilometer

    2 weeks

Secondary Outcomes (2)

  • microhardness of clear aligner

    2 weeks

  • thickness change of clear aligner

    2 weeks

Study Arms (2)

Multi-layer clear aligners

EXPERIMENTAL

clear aligners fabricated from thermoplastic materials: multi-layer (0.76 mm). the material will be evaluated at three stages: before thermoforming (raw sheet), after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear. At each stage, specimens will be retrieved and tested for changes in mechanical properties, specifically surface roughness and hardness. Baseline control: Unused aligner sheets of both types to serve as reference for measurements.

Device: clear aligner

Single-layer clear aligners

EXPERIMENTAL

clear aligners fabricated from thermoplastic materials: single-layer (0.76 mm) . the material will be evaluated at three stages: before thermoforming (raw sheet), after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear. At each stage, specimens will be retrieved and tested for changes in mechanical properties, specifically surface roughness and hardness. Baseline control: Unused aligner sheets of both types to serve as reference for measurements.

Device: clear aligner

Interventions

Appliance Fabrication and Treatment Protocol * Digital impressions will be taken for all patients. * Treatment setup will be performed with standardized staging: maximum 0.25-0.3 mm linear movement or 2-3° rotation per stage. * Aligners will be fabricated by thermoforming using single and multilayer sheets (0.76 mm), cut and finished identically.

Multi-layer clear alignersSingle-layer clear aligners

Eligibility Criteria

Age16 Years - 24 Years
Sexall
Healthy VolunteersNo
Age GroupsChild (0-17), Adult (18-64)

You may qualify if:

  • Class I malocclusion with mild-moderate crowding (≤5 mm per arch).
  • Full permanent dentition (excluding third molars).
  • No restorations, caries, or attachments planned on the labial surface of upper/lower central incisors.

You may not qualify if:

  • Systemic disease affecting saliva.
  • Parafunctional habits (bruxism, nail-biting).
  • Smoking.
  • Pregnancy.
  • Previous orthodontic treatment within 1 year.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Mansoura university

Al Mansurah, Egypt

Location

MeSH Terms

Interventions

Orthodontic Appliances, Removable

Intervention Hierarchy (Ancestors)

Orthodontic AppliancesOrthodonticsDentistry

Study Design

Study Type
interventional
Phase
not applicable
Allocation
RANDOMIZED
Masking
NONE
Purpose
TREATMENT
Intervention Model
PARALLEL
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

February 15, 2026

First Posted

March 4, 2026

Study Start

January 1, 2026

Primary Completion (Estimated)

January 1, 2027

Study Completion (Estimated)

February 1, 2027

Last Updated

March 4, 2026

Record last verified: 2025-12

Locations