Procedural Mitral Isthmus Block Durability After Pulsed-Field Ablation in Patients with Non-Paroxysmal Atrial Fibrillation
FARA Block
1 other identifier
observational
40
0 countries
N/A
Brief Summary
Mitral isthmus is one of the targets for the catheter ablation of non-paroxysmal atrial fibrillation (AF), in which pulmonary veins isolation alone is not deemed sufficient. Typically, lateral mitral isthmus ablation line is performed from the mitral annulus to the ostium of the left inferior pulmonary vein or to the posterior base of the left atrial appendage. When conduction block across the mitral isthmus is achieved, the standard practice using radiofrequency energy is to wait 20 minutes to verify durability of the conduction block. Currently, there is an increase in procedures performed using pulsed-field energy (PF). The procedure is in most centers terminated immediately after the energy is delivered, and, unlike radiofrequency energy procedures, there is no waiting period to see if the conduction through the ablation lines returns. However return of conduction across the mitral isthmus has been described during reablation procedures performed for clinical recurrence of arrhythmia (perimitral flutter or atrial fibrillation). The presented study is a follow-up of previous work, which included 30 patients with non-paroxysmal AF, who underwent PF ablation including mitral isthmus ablation as part of the procedure. Ablation of the mitral isthmus was performed by repeated series of 9 PF energy applications. After each series a waiting period of 20 minutes followed. In case of recurrence of conduction, another series of 9 PF applications was delivered followed by a new waiting period. In the cases of reconduction after the 3rd series, one last series of PF applications was performed, where the number of applications was left at the discretion of the operator, where the total number of applications delivered to the mitral isthmus could not exceed 50. We found that although conduction block on the mitral isthmus was achieved in 90 % of patients after all series, it was only in 33,3 % of patients after the first series. Repeated waiting and multiple ablation series prolonged the procedure unnecessarily. On the other hand, a very high number of pulsed-field energy applications applied initially could be associated with a risk of hemolysis. So far, the number of PF applications up to 80-100 were demonstrated to be safe. This present study aims to determine whether increasing the number of applications in the first series delivered to the mitral isthmus will be associated with faster and durable achievement of conduction block across the mitral isthmus. A total of 40 patients with symptomatic non-paroxysmal AF, indicated for catheter ablation according to current guidelines, will be included. Patients with previous left atrial ablation, presenting left ventricular dysfunction with LV EF \< 30%, as well as patients at high risk of prolonged analgosedation (i.g. history of severe COPD, treated OSA) will be excluded. The procedure will be performed according to the standards of our center, i.e. pulmonary veins isolation, left atrial posterior wall ablation and mitral isthmus ablation will be performed. All procedures will be performed under analgosedation or general anesthesia controlled by an anesthesiologist. All ablations will be made using PF energy (system FARAPULSE, Boston sci., USA) and under control of intracardiac echocardiography. In contrast to previous work, a total of 20 applications of PF energy will be administered to the mitral isthmus in the first series of ablation. A waiting period of 20 minutes will follow, during which the conduction block across the mitral isthmus will be verified by assessment of the activation sequence on the decapolar catheter in the coronary sinus when pacing from the base of the left atrial appendage and by assessment of the activation of the left atrial appendage when pacing from the distal coronary sinus (or by differential pacing in case of uncertainity). If there is no recurrence of conduction across the mitral isthmus within 20 min, the procedure will be terminated. If recurrence does occur, a second series of 20 PF energy applications will be administered and another 20-minute waiting period will be initiated. In the case of reconduction after the 2nd series, one last optional ablation series will be delivered at the discretion of the operator. For safety reasons, the total waiting time will be 40 minutes and the total number of PF energy applications to the mitral isthmus will be limited to 50 (in the third series, only 10 applications can be delivered). After the procedure, the catheters and sheaths will be withdrawn and the site of puncture fixed with Z suture. All patients will receive 1000 mL of saline postproceduraly and will be endouredged to drink sufficient amount of fluids on the day after the procedure. Renal function (BUN, creatinine) will be assessed on the following day after the procedure.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Jan 2025
Shorter than P25 for all trials
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
January 1, 2025
CompletedFirst Submitted
Initial submission to the registry
January 27, 2025
CompletedFirst Posted
Study publicly available on registry
January 31, 2025
CompletedPrimary Completion
Last participant's last visit for primary outcome
April 1, 2025
CompletedStudy Completion
Last participant's last visit for all outcomes
April 1, 2025
CompletedJanuary 31, 2025
January 1, 2025
3 months
January 27, 2025
January 27, 2025
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Mitral isthmus block durability after 1 series of PF applications
Acute mitral isthmus conduction block sustained for a waiting period of 20 minutes after 1 series of 20 PF applications
20 minutes after last PF application
Secondary Outcomes (1)
Overall mitral isthmus block durability
20 minutes after last PF application of last ablation series
Eligibility Criteria
Patients referred for catheter ablation of non paroxysmal AF by referring cardiologists and from arrythmology clinic
You may qualify if:
- adult patients with symptomatic non-paroxysmal atrial fibrillation indicated for catheter ablation according to the current guidelines
You may not qualify if:
- Contraindication to catheter ablation according to the current guidelines
- previous left atrial ablation
- left ventricular dysfunction with LV EF \< 30%
- Patients at high risk of prolonged analgosedation, e.g. history of severe COPD (stage 3 or 4), obstructive sleep apnea on treatment
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Related Publications (1)
Hornof J, Hozman M, Herman D, Romanenko O, Hassouna S, Vesela J, Filipcova V, Poviser L, Karch J, Hozmanova J, Znojilova L, Molova A, Penkava V, Osmancik P. Acute Efficacy of Pulsed-Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings. J Cardiovasc Electrophysiol. 2025 Dec 27. doi: 10.1111/jce.70236. Online ahead of print.
PMID: 41456097DERIVED
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Central Study Contacts
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
January 27, 2025
First Posted
January 31, 2025
Study Start
January 1, 2025
Primary Completion
April 1, 2025
Study Completion
April 1, 2025
Last Updated
January 31, 2025
Record last verified: 2025-01