NCT06412159

Brief Summary

Purpose:Within subject study aim to compare the overall accuracy and fit of different components for mandibular metallic removable partial denture (RPD) frameworks fabricated by selective laser melting using combined analog-digital, and fully digital impression techniques. Material and methods. Two RPD frameworks were fabricated for each of the 24 participants using each of the 2 techniques of the 24 participants enrolled, were of mandibular Kennedy class I, the first technique was the combined analog-digital workflow had the analog steps include: a physical impression was made using polyvinyl siloxane, stone casts were made, then the stone cast was scanned with a laboratory scanner to generate a digital cast. The 3Shape CAD software was then used to design a digital RPD, which was fabricated from a cobalt-chroumum alloy by selective laser melting. The second technique was fully digital where an intraoral digital scanner was used to make a definitive scan, which was sent to the 3Shape software for digitally designing the RPD framework and subsequent selective laser melting for fabrication. For both frameworks in the same participant, the same design was used for consistency. To assess the accuracy of fit, based on STL data analysis (intra-oral digital superimposition evaluation), a color map was constructed using non metrology software, and overall fit accuracy and the misfit (distance between each framework component and the reference intra-oral scan) were measured at rest, guiding plane and lingual plate areas.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
24

participants targeted

Target at below P25 for not_applicable

Timeline
Completed

Started Jan 2023

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

January 1, 2023

Completed
10 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

November 1, 2023

Completed
3 months until next milestone

Study Completion

Last participant's last visit for all outcomes

February 1, 2024

Completed
3 months until next milestone

First Submitted

Initial submission to the registry

May 3, 2024

Completed
11 days until next milestone

First Posted

Study publicly available on registry

May 14, 2024

Completed
Last Updated

September 19, 2024

Status Verified

September 1, 2024

Enrollment Period

10 months

First QC Date

May 3, 2024

Last Update Submit

September 5, 2024

Conditions

Keywords

partial dentureintra oraldigital evaluationaccuracyselective laser melting

Outcome Measures

Primary Outcomes (1)

  • Intra-oral digital Evaluation of fit accuracy for removable partial denture frameworks

    Intra-oral digital Accuracy of fit evaluation between frame works by using medit compare software to exclude the value of point difference in different area at occlusal rest major connector

    immediately after insertion of removable partial denture frame work

Study Arms (2)

selective laser melting removable partial denture frameworks fabricated by conventional technique

OTHER

selective laser melting removable partial denture frameworks fabricated by conventional technique

Other: Selective laser melting framework was fabricated using completely digital workflow

selective laser melting framework was fabricated using completely digital workflow

OTHER

selective laser melting framework was fabricated using completely digital workflow

Other: Selective laser melting framework was fabricated using completely digital workflow

Interventions

completely digital work flow Conventional technique versus complete digital technique

selective laser melting framework was fabricated using completely digital workflowselective laser melting removable partial denture frameworks fabricated by conventional technique

Eligibility Criteria

Age50 Years - 65 Years
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • mandibular Class I Kennedy classification were selected randomly from the outpatient clinic of the prosthodontic department

You may not qualify if:

  • other classes of removable partial denture maxillary partially edentulous patients

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Nourhan Ragheb

Kafr Elsheikh, Kafr el-Sheikh Governorate, 6850001, Egypt

Location

Related Publications (1)

  • Elgamal M, Ibrahim AM, Fadl BT, Ragheb NA. Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows: A cross-over clinical study. BMC Oral Health. 2025 May 28;25(1):824. doi: 10.1186/s12903-025-06214-9.

Study Design

Study Type
interventional
Phase
not applicable
Allocation
NON RANDOMIZED
Masking
DOUBLE
Who Masked
PARTICIPANT, CARE PROVIDER
Purpose
TREATMENT
Intervention Model
CROSSOVER
Sponsor Type
OTHER
Responsible Party
PRINCIPAL INVESTIGATOR
PI Title
associate professor

Study Record Dates

First Submitted

May 3, 2024

First Posted

May 14, 2024

Study Start

January 1, 2023

Primary Completion

November 1, 2023

Study Completion

February 1, 2024

Last Updated

September 19, 2024

Record last verified: 2024-09

Locations