Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
Intra-oral Digital Evaluation of Fit Accuracy for Removable Partial Denture Frameworks Fabricated by Selective Laser Melting Using 2 Different Impression Techniques. Within Subjected Study
1 other identifier
interventional
24
1 country
1
Brief Summary
Purpose:Within subject study aim to compare the overall accuracy and fit of different components for mandibular metallic removable partial denture (RPD) frameworks fabricated by selective laser melting using combined analog-digital, and fully digital impression techniques. Material and methods. Two RPD frameworks were fabricated for each of the 24 participants using each of the 2 techniques of the 24 participants enrolled, were of mandibular Kennedy class I, the first technique was the combined analog-digital workflow had the analog steps include: a physical impression was made using polyvinyl siloxane, stone casts were made, then the stone cast was scanned with a laboratory scanner to generate a digital cast. The 3Shape CAD software was then used to design a digital RPD, which was fabricated from a cobalt-chroumum alloy by selective laser melting. The second technique was fully digital where an intraoral digital scanner was used to make a definitive scan, which was sent to the 3Shape software for digitally designing the RPD framework and subsequent selective laser melting for fabrication. For both frameworks in the same participant, the same design was used for consistency. To assess the accuracy of fit, based on STL data analysis (intra-oral digital superimposition evaluation), a color map was constructed using non metrology software, and overall fit accuracy and the misfit (distance between each framework component and the reference intra-oral scan) were measured at rest, guiding plane and lingual plate areas.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Jan 2023
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
January 1, 2023
CompletedPrimary Completion
Last participant's last visit for primary outcome
November 1, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
February 1, 2024
CompletedFirst Submitted
Initial submission to the registry
May 3, 2024
CompletedFirst Posted
Study publicly available on registry
May 14, 2024
CompletedSeptember 19, 2024
September 1, 2024
10 months
May 3, 2024
September 5, 2024
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Intra-oral digital Evaluation of fit accuracy for removable partial denture frameworks
Intra-oral digital Accuracy of fit evaluation between frame works by using medit compare software to exclude the value of point difference in different area at occlusal rest major connector
immediately after insertion of removable partial denture frame work
Study Arms (2)
selective laser melting removable partial denture frameworks fabricated by conventional technique
OTHERselective laser melting removable partial denture frameworks fabricated by conventional technique
selective laser melting framework was fabricated using completely digital workflow
OTHERselective laser melting framework was fabricated using completely digital workflow
Interventions
completely digital work flow Conventional technique versus complete digital technique
Eligibility Criteria
You may qualify if:
- mandibular Class I Kennedy classification were selected randomly from the outpatient clinic of the prosthodontic department
You may not qualify if:
- other classes of removable partial denture maxillary partially edentulous patients
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Nourhan Ragheb
Kafr Elsheikh, Kafr el-Sheikh Governorate, 6850001, Egypt
Related Publications (1)
Elgamal M, Ibrahim AM, Fadl BT, Ragheb NA. Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows: A cross-over clinical study. BMC Oral Health. 2025 May 28;25(1):824. doi: 10.1186/s12903-025-06214-9.
PMID: 40437453DERIVED
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NON RANDOMIZED
- Masking
- DOUBLE
- Who Masked
- PARTICIPANT, CARE PROVIDER
- Purpose
- TREATMENT
- Intervention Model
- CROSSOVER
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- associate professor
Study Record Dates
First Submitted
May 3, 2024
First Posted
May 14, 2024
Study Start
January 1, 2023
Primary Completion
November 1, 2023
Study Completion
February 1, 2024
Last Updated
September 19, 2024
Record last verified: 2024-09