Ultrasound Examination for Spleen Volume Evaluation in Myeloproliferative Neoplasms
1 other identifier
observational
45
1 country
1
Brief Summary
Adult patients (\>18 years) with newly diagnosis of Ph negative myeloproliferative neoplasms (MPNs) according to WHO 2016 criteria, will be recruited to this study. This study is the result of the collaboration the Hematology Division of Federico II University Medical School of Naples (Italy), that performed the US investigation and the IRCCS SYNLAB SDN where the patients carried out MR. The study is conducted in accordance with the Declaration of Helsinki. All subjects gave informed consent to receive both US and MR scans of the spleen. All spleen US scans were performed by the same operator (with\>10 years of experience in abdominal US), who used an EPIQ 5 Philips instrument with a 1-5 MHz broadband curvilinear probe. The spleen was scanned in patients who were fasting, in the longitudinal and transverse planes by using an intercostal approach, a subcostal approach, or both. The patient was placed in a supine or right-sided position until complete organ visualization was achieved. Perimeter, longitudinal diameter (LD), and area, defined as the maximum measurements with splenic borders and angles clearly defined, were measured, and SV (in milliliters) was calculated automatically. For each subject, the mean value of 3 measurements repeated on the same imaging session was calculated and recorded for final analysis. Within two weeks from the US, each patient underwent an MRI of the upper abdomen to evaluate the splenic volume. MRI examinations were performed using a 3T Biograph mMR scanner (Siemens Healthcare, Erlangen, Germany) with 4-channel flex phased-array body coil. Routine clinical abdominal MRI acquisition includes coronal T2W Half-Fourier Acquisition Single-shot Turbo spin Echo imaging (HASTE), axial T1 Dual-echo FSE, axial T2 TSE Fat Sat, and an axial diffusion-weighted imaging (DWI). The DWI includes an apparent diffusion coefficient (ADC) map that was automatically generated at the time of acquisition. At last, an isotropic 2mm3 axial Volumetric Interpolated Breath-hold Examination (VIBE) sequence for SV evaluation was acquired. For the latter, attention was paid to optimize the field of view to the spleen, in order to reduce patient's apnea and possible respiratory artifacts. A radiologist with mote than 10 years of experience in abdominal MRI reporting performed measurement of the three orthogonal diameters of the spleen for each patient. Subsequently, SV was calculated using ITK-SNAP software and semi-automatic 3D segmentation approach, firstly based on a signal threshold.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Apr 2017
Longer than P75 for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
April 20, 2017
CompletedPrimary Completion
Last participant's last visit for primary outcome
January 20, 2024
CompletedStudy Completion
Last participant's last visit for all outcomes
March 20, 2024
CompletedFirst Submitted
Initial submission to the registry
April 14, 2024
CompletedFirst Posted
Study publicly available on registry
April 17, 2024
CompletedApril 17, 2024
April 1, 2024
6.8 years
April 14, 2024
April 14, 2024
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
agreement between two different diagnostic methods
Estimation of Spleen Volume and Longitudinal Diameter obtained with US measurement were compared to that obtained using MRI conducted in a time span of 2 weeks
2 weeks
Interventions
Within two weeks from the US, each patient underwent an MRI of the upper abdomen to evaluate the splenic volume. MRI examinations were performed using a 3T Biograph mMR scanner (Siemens Healthcare, Erlangen, Germany) with 4-channel flex phased-array body coil. Routine clinical abdominal MRI acquisition includes coronal T2W Half-Fourier Acquisition Single-shot Turbo spin Echo imaging (HASTE), axial T1 Dual-echo FSE, axial T2 TSE Fat Sat, and an axial diffusion-weighted imaging (DWI).
Eligibility Criteria
This is a retrospective, non-interventional study. Data were retrospectively collected from all patients who completed US and MRI scans
You may qualify if:
- diagnosis of Philadelphia (Ph) negative chronic myeloproliferative neoplasms (MPN), according to WHO 2016 criteria
- age \>18 years
- execution of MRI of the upper abdomen within two weeks from the US,
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Federico II University
Naples, 80131, Italy
MeSH Terms
Conditions
Interventions
Condition Hierarchy (Ancestors)
Intervention Hierarchy (Ancestors)
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- RETROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Full Professor
Study Record Dates
First Submitted
April 14, 2024
First Posted
April 17, 2024
Study Start
April 20, 2017
Primary Completion
January 20, 2024
Study Completion
March 20, 2024
Last Updated
April 17, 2024
Record last verified: 2024-04
Data Sharing
- IPD Sharing
- Will not share