The Safety and Effectiveness of CVA-FLOW Software Device for Acute Ischemic Stroke
A Single-center, Clinical Trial to Evaluate the Safety and Effectiveness of CVA-FLOW Software Device for Acute Ischemic Stroke
1 other identifier
interventional
100
1 country
1
Brief Summary
The purpose of this study is to demonstrate the effectiveness and safety of CVA-FLOW, a digital health AI based Telestroke system developed by CVAID Ltd. Company aims to assist certified medical staff to triage acute ischemic stroke patients using dedicated algorithms in order to support application for market approval for CVA-FLOW device.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P75+ for not_applicable stroke
Started Nov 2022
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
November 8, 2022
CompletedFirst Submitted
Initial submission to the registry
February 7, 2023
CompletedFirst Posted
Study publicly available on registry
February 27, 2023
CompletedPrimary Completion
Last participant's last visit for primary outcome
October 30, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
November 30, 2023
CompletedAugust 30, 2023
August 1, 2023
12 months
February 7, 2023
August 29, 2023
Conditions
Outcome Measures
Primary Outcomes (2)
Sensitivity and specificity of stroke severity classification by CVA-CORE algorithm
Stroke severity classification will be calculated by the CVA-CORE system algorithm and compared to the imaging results (interpretation).
At admission
Sensitivity and specificity of stroke severity classification by CVA-CORE algorithm
Stroke severity classification will be calculated by the CVA-CORE system algorithm and compared to the imaging results (interpretation).
after 24 hours
Secondary Outcomes (2)
Device operational performance
At admission
Device operational performance
after 24 hours
Study Arms (1)
Evaluate the safety and effectiveness of CVA-FLOW Software Device for acute ischemic stroke
EXPERIMENTALThe purpose of this study is to demonstrate the effectiveness and safety of CVA-FLOW, a digital health AI based Telestroke system developed by CVAID Ltd. Company aims to assist certified medical staff to triage acute ischemic stroke patients using dedicated algorithms in order to support application for market approval for CVA-FLOW device.
Interventions
CVA-FLOW is a Telestroke mobile software solution that enables the neurologist to remotely assess, on his smartphone, patients suspected with stroke. Real-time, objective, patient-specific data such as images, videos and vocal records of the patient, are acquired by a first responder (CVA-COLLECTOR) at the patient's location. This allows the neurologist to complete the NIH Stroke Scale and independently reach a diagnostic conclusion and treatment plan (CVA-MED).
Eligibility Criteria
You may qualify if:
- Suspected hyper-acute stroke patient at the ED, prior to treatment (tPA or EVT)
- Age≥18
You may not qualify if:
- Intubated patients upon arrival
- Time from stroke symptoms onset \> 24h
- Patients post treatment (tPA of EVT)
- Patient in acute psychosis state
- Patients who do not speak Hebrew as their mother tongue
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Cvaid Medicallead
Study Sites (1)
Shaare Zedek Medical Center
Jerusalem, Israel
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- DIAGNOSTIC
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
February 7, 2023
First Posted
February 27, 2023
Study Start
November 8, 2022
Primary Completion
October 30, 2023
Study Completion
November 30, 2023
Last Updated
August 30, 2023
Record last verified: 2023-08
Data Sharing
- IPD Sharing
- Will not share