Effect of Intermittent Pneumatic Compression Device of Lower Limbs in Oligohydramnios
Amniotic Fluid Index and Fetal Doppler Indices Measurment After Application of Intermittent Pneumatic Compression Device on Lower Limbs in Pregnant Women With Oligohydramnios
1 other identifier
interventional
30
0 countries
N/A
Brief Summary
the study will examine the effect of application of intermittent pneumatic pressure device on lower limbs on the amniotic fluid amount and fetal doppler indices in women with oligohydramnios
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Aug 2022
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
December 7, 2021
CompletedFirst Posted
Study publicly available on registry
July 26, 2022
CompletedStudy Start
First participant enrolled
August 15, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 1, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
December 31, 2023
CompletedJuly 26, 2022
July 1, 2022
1.3 years
December 7, 2021
July 25, 2022
Conditions
Outcome Measures
Primary Outcomes (5)
pulsatility index in maternal uterine artery
Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the maternal uterine artery will be calculated before the application of IPC on lower maternal limbs PI of the maternal uterine artery will be re-calculated after the application of IPC on lower maternal limbs for one hour
one hour
pulsatility index in fetal umbilical artery
Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal umbilical artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal umbilical artery will be re-calculated after the application of IPC on lower maternal limbs for one hour
one hour
pulsatility index in fetal middle cerebral artery
Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal middle cerebral artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal middle cerebral artery will be re-calculated after the application of IPC on lower maternal limbs for one hour
one hour
pulsatility index in fetal renal artery
Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal renal artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal renal artery will be re-calculated after the application of IPC on lower maternal limbs for one hour
one hour
amniotic fluid index
basline amniotic fluid index (AFI in centemeters) will be calculated before the application of IPC on lower maternal limbs amniotic fluid index (AFI in centemeters) will be re-calculated after the application of IPC on lower maternal limbs for one hour
one hour
Study Arms (1)
pregnant women with idiopathic oligohydramnios
EXPERIMENTALwomen with singleton pregnancy between 32-41 weeks oligohydramnios diagnosed by ultrasound by the amniotic fluid index (AFI) method oligohydramnios is diagnosed if AFI index is less than 5 cm
Interventions
application of intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System) on lower limbs and its effect on fetal and maternal doppler and amniotic fluid index in women with oligohydramnios. the compression system will be applicated on lower limbs for one hour in which it will produce intermittent compression on lower limbs. amniotic fluid amnout assessment will be done after this including doppler studies in order to detect any change in amniotic fluid amount or dopper.
Eligibility Criteria
You may qualify if:
- pregnant women with a diagnosis of oligohydramnios
You may not qualify if:
- fetal malformation
- rupture of membranes
- documented viral infection with rubella, cytomegalovirus, herpes simplex, toxoplsma in pregnancy
Contact the study team to confirm eligibility.
Sponsors & Collaborators
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
inshirah sgayer, MD
GALILEE MEDICAL CENTER ISRAEL
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- OTHER
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER GOV
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Dr. Inshirah Sgayer
Study Record Dates
First Submitted
December 7, 2021
First Posted
July 26, 2022
Study Start
August 15, 2022
Primary Completion
December 1, 2023
Study Completion
December 31, 2023
Last Updated
July 26, 2022
Record last verified: 2022-07