The Effects of Lateral 45° Downward Position on the Optic Nerve Sheath Diameter
1 other identifier
observational
26
0 countries
N/A
Brief Summary
Trendelenburg position and carbon dioxide (CO2) pneumoperitoneum are in association with increased intracranial pressure (ICP) reflected by the optic nerve sheath diameter (ONSD). Measurement of ONSD by ultrasound (US) guidance can be used in the diagnosis of ICP. The investigators interrogated the effects of lateral 45° downward position and CO2 insufflation on ONSD in patients undergoing laparoscopic transperitoneal nephrectomy.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for all trials
Started Dec 2016
Typical duration for all trials
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
December 1, 2016
CompletedPrimary Completion
Last participant's last visit for primary outcome
March 2, 2017
CompletedStudy Completion
Last participant's last visit for all outcomes
January 1, 2019
CompletedFirst Submitted
Initial submission to the registry
December 5, 2021
CompletedFirst Posted
Study publicly available on registry
January 11, 2022
CompletedJanuary 11, 2022
December 1, 2021
3 months
December 5, 2021
December 22, 2021
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
optic nerve sheath diameter
Measurement of optic nerve sheath diameter by ultrasound (US) guidance can be used in the diagnosis of increased intracranial pressure (ICP).
up to 24 hours
Secondary Outcomes (2)
Respiratory parameters
up to 24 hours
Hemodynamic parameters
up to 24 hours
Study Arms (1)
Group 1
The patients undergoing laparoscopic transperitoneal nephrectomy.
Interventions
Measurement of the optic nerve sheath diameter (ONSD) by ultrasound guidance can be used in the diagnosis of increased ICP. The investigators interrogated the effects of lateral 45° downward position and CO2 insufflation on ONSD in patients undergoing laparoscopic transperitoneal nephrectomy.
Eligibility Criteria
Twenty-six patients who have undergone laparoscopic transperitoneal nephrectomy in the period of December 2016 and February 2017 were included in this study.
You may qualify if:
- All patients older than 18 years who have undergone laparoscopic transperitoneal nephrectomy.
You may not qualify if:
- Those who have neurological and cerebrovascular disease.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Related Publications (4)
Verdonck P, Kalmar AF, Suy K, Geeraerts T, Vercauteren M, Mottrie A, De Wolf AM, Hendrickx JF. Optic nerve sheath diameter remains constant during robot assisted laparoscopic radical prostatectomy. PLoS One. 2014 Nov 4;9(11):e111916. doi: 10.1371/journal.pone.0111916. eCollection 2014.
PMID: 25369152BACKGROUNDChin JH, Seo H, Lee EH, Lee J, Hong JH, Hwang JH, Kim YK. Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position. BMC Anesthesiol. 2015 Mar 31;15:43. doi: 10.1186/s12871-015-0025-9. eCollection 2015.
PMID: 25861241BACKGROUNDBlecha S, Harth M, Schlachetzki F, Zeman F, Blecha C, Flora P, Burger M, Denzinger S, Graf BM, Helbig H, Pawlik MT. Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45 degrees Trendelenburg position. BMC Anesthesiol. 2017 Mar 11;17(1):40. doi: 10.1186/s12871-017-0333-3.
PMID: 28284189BACKGROUNDAtasever AG, Salviz EA, Senturk Ciftci H, Bingul ES, Sivrikoz N, Erdem S, Savran Karadeniz M. The Effects of Lateral 45 degrees Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study. J Laparoendosc Adv Surg Tech A. 2023 Feb;33(2):171-176. doi: 10.1089/lap.2022.0344. Epub 2022 Aug 25.
PMID: 36036829DERIVED
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Associate Professor
Study Record Dates
First Submitted
December 5, 2021
First Posted
January 11, 2022
Study Start
December 1, 2016
Primary Completion
March 2, 2017
Study Completion
January 1, 2019
Last Updated
January 11, 2022
Record last verified: 2021-12
Data Sharing
- IPD Sharing
- Will not share