Safety and Efficacy of an Ab Interno Gelatin Stent (XEN63) With or Without Mitomycin C
1 other identifier
observational
30
1 country
1
Brief Summary
The Xen gelatin microstent (Allergan, CA, USA) is a 6mm hydrophobic, bleb-forming microinvasive glaucoma surgery (MIGS).1 Creation of a filtering bleb through the gel stent and under the conjunctiva lowers intraocular pressure (IOP) by bypassing the natural outflow pathway of aqueous. Currently three Xen models have been developed: 45, 63, and 140 um internal lumen diameters.2 XEN45 ab interno gelatin stent was the first to be approved for clinical use in Canada.3 A recent retrospective cohort study showed comparable safety and risk of failure to trabeculectomy.4 Amongst the main advantages of this device is the ability to create a bleb without dissecting and disrupting tissue, thus decreasing the amount of wound healing and potentially limiting bleb failure. Recently, the XEN63 ab interno gelatin stent was approved by Health Canada for clinical use in Canada. Being a new device, to date, no study has examined the effect of XEN63 ab interno gelatin stent on anti-glaucoma drops burden and IOP. The aim of this study is to investigate the safety and efficacy of the XEN63 ab interno gelatin stent to provide insights for ophthalmologists who will want to add this technique to their practice.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for all trials
Started Nov 2020
Typical duration for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
November 9, 2020
CompletedFirst Submitted
Initial submission to the registry
February 9, 2021
CompletedFirst Posted
Study publicly available on registry
February 11, 2021
CompletedPrimary Completion
Last participant's last visit for primary outcome
June 9, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
June 9, 2023
CompletedSeptember 28, 2022
September 1, 2022
2.6 years
February 9, 2021
September 26, 2022
Conditions
Outcome Measures
Primary Outcomes (3)
Complete Success
Intraocular Pressure: 6-17 mmHg and on no glaucoma medications at least 1 month after surgery with no reoperation using the Goldmann Applanation Tonometer..
1 month post op to post op month 12
Absence of complications
Absence of the following complications as reported during slitlamp examination: i. Starting after POM1: shallow AC w/ iridocorneal touch, any hyphema, corneal edema, choroidal effusion, malignant glaucoma, dellen/non-healing epithelial defect, ptosis, diplopia. ii. At any point: additional glaucoma surgery, loss of light perception vision, vitreous hemorrhage, ≥2mm hyphema, hypotony maculopathy, implant migration/blockage/exposure/extrusion, macular edema, choroidal effusion/hemorrhage requiring drainage, suprachoroidal hemorrhage, retinal detachment, blebitis/endophthalmitis
post op day 1 to post op month 12
Qualified Success
a. 'Complete success' criteria except that Intraocular Pressure (IOP) can be above IOP thresholds, and then reduced to within the 'Complete criteria' by medications or laser in 3 visits or less as measured by Goldmann Applanation Tonometry.
post op month 1 to post op month 12
Study Arms (1)
Open Angle Glaucoma
Patients aged 30-90 Primary open angle glaucoma on maximum tolerated medical therapy Going to receive XEN63 ab interno gelatin stent with or without MMC in study eye ± cataract surgery
Interventions
The Xen gelatin microstent (Allergan, CA, USA) is a 6mm gelatin tube used in microinvasive glaucoma surgery (MIGS) to create a bleb. A bleb is a fluid filled blister located in the tissue covering the white portion of the eye (the conjunctiva) created after glaucoma surgery. The bleb allows the eye pressure (intraocular pressure - IOP) to be lowered by bypassing the natural pathways by which the fluid called aqueous leaves the eye and redirecting it towards the bleb to be absorbed by other pathways. Amongst the main advantages of this device is the ability to create a bleb without disrupting tissue unlike other methods of glaucoma surgery (e.g., trabeculectomy). This decreases the amount of wound healing and scarring, and potentially limiting bleb failure.
Eligibility Criteria
Patients scheduled to undergo Xen 63 implantation for open angle glaucoma with or without cataract surgery
You may qualify if:
- Patients aged 30-90 Primary open angle glaucoma on maximum tolerated medical therapy Going to receive XEN63 ab interno gelatin stent with or without MMC in study eye ± cataract surgery
You may not qualify if:
- Other forms of glaucoma
- Previous glaucoma shunt/valve in the target quadrant of study eye
- Presence of conjunctival scarring, prior conjunctival surgery or other conjunctival pathologies (e.g., pterygium) in the target quadrant of study eye
- Active inflammation (e.g., blepharitis, conjunctivitis, keratitis, uveitis), active iris neovascularization or neovascularization of the iris within six months of the surgical date
- Presence of anterior chamber intraocular lens, intraocular silicone oil, vitreous present in the anterior chamber, impaired episcleral venous drainage (e.g., Sturge-Weber or nanophthalmos or other evidence of elevated venous pressure)
- Known or suspected allergy or sensitivity to drugs required for the surgical procedure or any of the device components (e.g., porcine products or glutaraldehyde), history of dermatologic keloid formation.
- Prior CPC, corneal graft (PKP, DALK, DSAEK, DMEK)
- Other forms of combined surgery (cornea, retina) besides cataract surgery
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Prism Eye Institutelead
- Allergancollaborator
Study Sites (1)
Prism Eye Institute
Oakville, Ontario, L6H 0J8, Canada
Related Publications (3)
Conlon R, Saheb H, Ahmed II. Glaucoma treatment trends: a review. Can J Ophthalmol. 2017 Feb;52(1):114-124. doi: 10.1016/j.jcjo.2016.07.013. Epub 2016 Nov 17.
PMID: 28237137BACKGROUNDGreen W, Lind JT, Sheybani A. Review of the Xen Gel Stent and InnFocus MicroShunt. Curr Opin Ophthalmol. 2018 Mar;29(2):162-170. doi: 10.1097/ICU.0000000000000462.
PMID: 29319544BACKGROUNDSchlenker MB, Gulamhusein H, Conrad-Hengerer I, Somers A, Lenzhofer M, Stalmans I, Reitsamer H, Hengerer FH, Ahmed IIK. Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy. Ophthalmology. 2017 Nov;124(11):1579-1588. doi: 10.1016/j.ophtha.2017.05.004. Epub 2017 Jun 7.
PMID: 28601250BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Iqbal Ahmed, MD
Prism Eye Institute
Central Study Contacts
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Target Duration
- 12 Months
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Principal Investigator
Study Record Dates
First Submitted
February 9, 2021
First Posted
February 11, 2021
Study Start
November 9, 2020
Primary Completion
June 9, 2023
Study Completion
June 9, 2023
Last Updated
September 28, 2022
Record last verified: 2022-09
Data Sharing
- IPD Sharing
- Will not share