NCT04401631

Brief Summary

This is a multicenter, prospective, observational study to evaluate the analytical performance of the Abionic IgE Multi-Allergen Test Panel on the abioSCOPE® device in a U.S. point-of-care environment within a clinical laboratory operating under a CLIA certificate for tests of moderate complexity. The study will assess point-of-care ('external') precision, sample type comparison and correlation with a reference method (Phadia Laboratory System, ThermoFisher Scientific).

Trial Health

30
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Timeline
Completed

Started Nov 2020

Shorter than P25 for all trials

Geographic Reach
1 country

3 active sites

Status
withdrawn

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

May 20, 2020

Completed
6 days until next milestone

First Posted

Study publicly available on registry

May 26, 2020

Completed
5 months until next milestone

Study Start

First participant enrolled

November 1, 2020

Completed
Same day until next milestone

Primary Completion

Last participant's last visit for primary outcome

November 1, 2020

Completed
1 month until next milestone

Study Completion

Last participant's last visit for all outcomes

December 1, 2020

Completed
Last Updated

October 5, 2020

Status Verified

October 1, 2020

Enrollment Period

Same day

First QC Date

May 20, 2020

Last Update Submit

October 1, 2020

Conditions

Keywords

AllergyAsthmaPoint-of-CareImmunoassayIn vitro DiagnosticTotal IgESpecific allergy

Outcome Measures

Primary Outcomes (3)

  • POC variance components (in a POL environment):

    * External Precision Study ('reproducibility study' 'site-to-site precision study'): Demonstrate that the imprecision of K3-EDTA venous plasma using the IVD CAPSULE Allergic Asthma panel on the abioSCOPE device (all 5 allergens/allergen mixes and total IgE) in the hands of trained Healthcare Professionals in a Physician Office Laboratory (POL) is within the expected range of the imprecision established in the clinical laboratory by Laboratory Scientists. * Operator-to-Operator imprecision on whole blood: Demonstrate that the between-Operator reproducibility of the total IgE of the IVD CAPSULE Allergic Asthma panel on the abioSCOPE device test results is within the expected range of variability. * Between-run reproducibility: Demonstrate that the between-run reproducibility of venous whole blood samples measured with the IVD CAPSULE Allergic Asthma panel on the abioSCOPE device (all 5 allergens/allergen mixes and total IgE) is within the expected range of variability.

    Day 1

  • Sample type comparison:

    Demonstrate that the IVD CAPSULE Allergic Asthma panel on the abioSCOPE device test results obtained from capillary whole blood correlates well with values obtained from K3-EDTA anticoagulated venous plasma and serum samples.

    Day 1

  • Method comparison

    Demonstrate that test results obtained with the total IgE test of the IVD CAPSULE Allergic Asthma panel on the abioSCOPE device correlates with total IgE test results from the reference method (Phadia Laboratory System, ThermoFisher Scientific).

    Day 1

Study Arms (1)

Interventions

* A minimum of 20 subjects with targeted levels of total IgE are needed to participate in the Operator-to-Operator whole blood study. * A minimum of 20 subjects with targeted levels of allergen-specific and total IgE are needed to participate in the capillary whole blood between-run imprecision study in the POL environment. * A minimum of 40 subjects with targeted levels of Fel d 1-specific IgE and total IgE are needed to participate in the sample type comparison study. These subjects will be recruited, and their samples analyzed at 1 POL. * A minimum of 300 subjects (approximately 100 subjects enrolled and evaluated at each of three sites) and with targeted levels of total IgE are needed to participate in the method comparison study.

Device: Blood Collection

Interventions

Between-Run Reproducibility K3-EDTA venous whole blood 3 mL 1 venous draw Operator-to-operator imprecision (abioSCOPE) K3-EDTA capillary whole blood 0.05 mL/draw; 0.15 mL total 3 finger sticks (3 different fingers) Sample type comparison (abioSCOPE) K3-EDTA capillary whole blood, venous serum, venous K3-EDTA plasma 0.35 mL (finger stick), 9 mL of whole blood to get a minimum of 3 mL of serum and 9 mL of whole blood K3-EDTA to get a minimum of 3 mL of plasma 1 finger stick; 1 venous draw into serum tube (9 mL) and 1 venous draw into K3-EDTA plasma tube (9 mL), in total 18 mL Method comparison (abioSCOPE and ImmunoCAP/Phadia) K3-EDTA capillary whole blood, venous K3-EDTA plasma 0.05 mL (finger stick), 9 mL of whole blood to get a minimum of 3 ml of plasma 1 finger stick; 1 venous draw into K3-EDTA plasma tube (9 mL tube)

Interventions

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersYes
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodNon-Probability Sample
Study Population

* A minimum of 20 subjects with targeted levels of total IgE are needed to participate in the Operator-to-Operator whole blood study. * A minimum of 20 subjects with targeted levels of allergen-specific and total IgE are needed to participate in the capillary whole blood between-run imprecision study in the POL environment. * A minimum of 40 subjects with targeted levels of Fel d 1-specific IgE and total IgE are needed to participate in the sample type comparison study. These subjects will be recruited, and their samples analyzed at 1 POL. * A minimum of 300 subjects (approximately 100 subjects enrolled and evaluated at each of three sites) and with targeted levels of total IgE are needed to participate in the method comparison study.

You may qualify if:

  • Provision and understanding of signed and dated written informed consent by the subject prior to any mandatory study-specific procedures, sample collection, or analysis.
  • Male or female, 18 years of age or older.

You may not qualify if:

  • Subject participating in another study that may influence test results.
  • Subject taking any of the following medications: systemic steroids (inhaled or nasal steroids are allowed), anti-cytokines or cytokines, systemic interferon (injection local interferon α for the treatment of HPV is allowed), anti-IgE therapy (approved or investigational) or treated with systemic chemotherapy.
  • History of cancer, autoimmune, or immune deficiency disease.
  • Suffering from a hematological pathology (coagulation disorder, severe anemia) that could interfere with the blood draw procedure.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (3)

George Washington University, Washington DC

Washington D.C., District of Columbia, 20037, United States

Location

Johns Hopkins University, Baltimore

Baltimore, Maryland, 21215, United States

Location

The Bernstein Clinical Research Center Cincinnati

Cincinnati, Ohio, 45231, United States

Location

MeSH Terms

Conditions

HypersensitivitySigns and SymptomsAsthma

Interventions

Blood Specimen Collection

Condition Hierarchy (Ancestors)

Immune System DiseasesPathological Conditions, Signs and SymptomsBronchial DiseasesRespiratory Tract DiseasesLung Diseases, ObstructiveLung DiseasesRespiratory HypersensitivityHypersensitivity, Immediate

Intervention Hierarchy (Ancestors)

Specimen HandlingClinical Laboratory TechniquesDiagnostic Techniques and ProceduresDiagnosisPuncturesSurgical Procedures, OperativeInvestigative Techniques
0

Study Design

Study Type
observational
Observational Model
COHORT
Time Perspective
PROSPECTIVE
Sponsor Type
INDUSTRY
Responsible Party
SPONSOR

Study Record Dates

First Submitted

May 20, 2020

First Posted

May 26, 2020

Study Start

November 1, 2020

Primary Completion

November 1, 2020

Study Completion

December 1, 2020

Last Updated

October 5, 2020

Record last verified: 2020-10

Locations