Non-Invasive Monitoring of Partial Pressure of Carbon Dioxide in Mechanically Ventilated Preterm Infants
1 other identifier
observational
27
1 country
1
Brief Summary
In mechanically ventilated preterm infants, the ability to monitor carbon dioxide partial pressure (pCO2) values is indispensable. The gold standard for pCO2 measurement is from an arterial blood sample (paCO2). This has two drawbacks: firstly, it requires an arterial line and, secondly, it does not provide the clinicians with a continuous measurement. At present, two alternative pCO2 monitoring systems are available in the field of neonatal intensive care medicine: end-tidal CO2 (etCO2) capnography and transcutaneous CO2 (tcCO2) measurements. Both methods have disadvantages including potential technical errors as well as pathologies that may reduce reliability as a surrogate for blood gas analysis (BGA). In particular, conventional side-stream etCO2 capnography underestimates pCO2 in presence of a tube leakage, which is a common occurrence in ventilated preterm infants where only tubes without cuff are used. Distal etCO2 (detCO2) by means of a double lumen endo-tracheal tube may solve the problem of unreliable etCO2 values in the presence of tube leakage. The aim of this study is to compare the agreement, precision and repeatability of the distal etCO2-measurement technique described by Kugelman et al. with respect to paCO2 and tcCO2 in mechanically ventilated preterm infants. Since ventilation strategies and pCO2 limits may vary among different centers, this study helps to determine which non-invasive CO2 monitoring system (detCO2 or tcO2) is more suitable in terms of applicability and reliability in preterm infants at our neonatal intensive care units.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for all trials
Started Nov 2018
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
November 1, 2018
CompletedFirst Submitted
Initial submission to the registry
November 26, 2018
CompletedFirst Posted
Study publicly available on registry
November 29, 2018
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 26, 2020
CompletedStudy Completion
Last participant's last visit for all outcomes
September 30, 2020
CompletedAugust 17, 2021
August 1, 2021
1.9 years
November 26, 2018
August 15, 2021
Conditions
Outcome Measures
Primary Outcomes (1)
Carbon Dioxide in Mechanically Ventilated Preterm Infants
partial pressure of carbon dioxide
48 hours
Interventions
Distal etCO2, tcCO2 and paCO2 values will be recorded simultaneously in ventilated preterm infants. We will measure etCO2 in a distal position using a double lumen tube connected to an external side-stream capnometer.
Eligibility Criteria
Mechanically Ventilated Preterm Infants
You may qualify if:
- Preterm infants with a current body weight between 1000 g and 3000 g who require intubation.
- Signed informed consent from parents or legal guardians.
- Expected to provide at least three measurements of paCO2 and detCO2.
You may not qualify if:
- Infants with known congenital anomalies of the heart and/or lung.
- Need for high frequency oscillation.
- Parents or legal guardians deny informed consent.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Tobias Wertherlead
Study Sites (1)
Department of Pediatrics, Division of Neonatology, Pediatric Intensive Care and Neuropediatrics, Medical University of Vienna
Vienna, 1090, Austria
Related Publications (47)
Morley CJ, Davis PG, Doyle LW, Brion LP, Hascoet JM, Carlin JB; COIN Trial Investigators. Nasal CPAP or intubation at birth for very preterm infants. N Engl J Med. 2008 Feb 14;358(7):700-8. doi: 10.1056/NEJMoa072788.
PMID: 18272893BACKGROUNDGiannakopoulou C, Korakaki E, Manoura A, Bikouvarakis S, Papageorgiou M, Gourgiotis D, Hatzidaki E. Significance of hypocarbia in the development of periventricular leukomalacia in preterm infants. Pediatr Int. 2004 Jun;46(3):268-73. doi: 10.1111/j.1442-200x.2004.01886.x.
PMID: 15151541BACKGROUNDErickson SJ, Grauaug A, Gurrin L, Swaminathan M. Hypocarbia in the ventilated preterm infant and its effect on intraventricular haemorrhage and bronchopulmonary dysplasia. J Paediatr Child Health. 2002 Dec;38(6):560-2. doi: 10.1046/j.1440-1754.2002.00041.x.
PMID: 12410866BACKGROUNDTobias JD. Transcutaneous carbon dioxide monitoring in infants and children. Paediatr Anaesth. 2009 May;19(5):434-44. doi: 10.1111/j.1460-9592.2009.02930.x. Epub 2009 Feb 19.
PMID: 19236597BACKGROUNDAliwalas LL, Noble L, Nesbitt K, Fallah S, Shah V, Shah PS. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation. J Perinatol. 2005 Jan;25(1):26-9. doi: 10.1038/sj.jp.7211202.
PMID: 15496874BACKGROUNDMolloy EJ, Deakins K. Are carbon dioxide detectors useful in neonates? Arch Dis Child Fetal Neonatal Ed. 2006 Jul;91(4):F295-8. doi: 10.1136/adc.2005.082008.
PMID: 16790735BACKGROUNDMcDonald MJ, Montgomery VL, Cerrito PB, Parrish CJ, Boland KA, Sullivan JE. Comparison of end-tidal CO2 and Paco2 in children receiving mechanical ventilation. Pediatr Crit Care Med. 2002 Jul;3(3):244-249. doi: 10.1097/00130478-200207000-00008.
PMID: 12780964BACKGROUNDSchmalisch G. Current methodological and technical limitations of time and volumetric capnography in newborns. Biomed Eng Online. 2016 Aug 30;15(1):104. doi: 10.1186/s12938-016-0228-4.
PMID: 27576441BACKGROUNDAnderson CT, Breen PH. Carbon dioxide kinetics and capnography during critical care. Crit Care. 2000;4(4):207-15. doi: 10.1186/cc696. Epub 2000 Jul 12.
PMID: 11094503BACKGROUNDWu CH, Chou HC, Hsieh WS, Chen WK, Huang PY, Tsao PN. Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit. Pediatr Pulmonol. 2003 Apr;35(4):292-5. doi: 10.1002/ppul.10260.
PMID: 12629627BACKGROUNDAmuchou Singh S, Singhal N. Dose end-tidal carbon dioxide measurement correlate with arterial carbon dioxide in extremely low birth weight infants in the first week of life? Indian Pediatr. 2006 Jan;43(1):20-5.
PMID: 16465002BACKGROUNDDargaville PA, Tingay DG. Lung protective ventilation in extremely preterm infants. J Paediatr Child Health. 2012 Sep;48(9):740-6. doi: 10.1111/j.1440-1754.2012.02532.x.
PMID: 22970667BACKGROUNDKeszler M, Nassabeh-Montazami S, Abubakar K. Evolution of tidal volume requirement during the first 3 weeks of life in infants <800 g ventilated with Volume Guarantee. Arch Dis Child Fetal Neonatal Ed. 2009 Jul;94(4):F279-82. doi: 10.1136/adc.2008.147157. Epub 2008 Dec 5.
PMID: 19060010BACKGROUNDNassabeh-Montazami S, Abubakar KM, Keszler M. The impact of instrumental dead-space in volume-targeted ventilation of the extremely low birth weight (ELBW) infant. Pediatr Pulmonol. 2009 Feb;44(2):128-33. doi: 10.1002/ppul.20954.
PMID: 19061234BACKGROUNDHagerty JJ, Kleinman ME, Zurakowski D, Lyons AC, Krauss B. Accuracy of a new low-flow sidestream capnography technology in newborns: a pilot study. J Perinatol. 2002 Apr-May;22(3):219-25. doi: 10.1038/sj.jp.7210672.
PMID: 11948385BACKGROUNDNangia S, Saili A, Dutta AK. End tidal carbon dioxide monitoring--its reliability in neonates. Indian J Pediatr. 1997 May-Jun;64(3):389-94. doi: 10.1007/BF02845211.
PMID: 10771861BACKGROUNDSingh BS, Gilbert U, Singh S, Govindaswami B. Sidestream microstream end tidal carbon dioxide measurements and blood gas correlations in neonatal intensive care unit. Pediatr Pulmonol. 2013 Mar;48(3):250-6. doi: 10.1002/ppul.22593. Epub 2012 May 15.
PMID: 22589000BACKGROUNDMahmoud RA, Proquitte H, Fawzy N, Buhrer C, Schmalisch G. Tracheal tube airleak in clinical practice and impact on tidal volume measurement in ventilated neonates. Pediatr Crit Care Med. 2011 Mar;12(2):197-202. doi: 10.1097/PCC.0b013e3181e89834.
PMID: 20581731BACKGROUNDSchmalisch G, Al-Gaaf S, Proquitte H, Roehr CC. Effect of endotracheal tube leak on capnographic measurements in a ventilated neonatal lung model. Physiol Meas. 2012 Oct;33(10):1631-41. doi: 10.1088/0967-3334/33/10/1631. Epub 2012 Sep 18.
PMID: 22986303BACKGROUNDProquitte H, Krause S, Rudiger M, Wauer RR, Schmalisch G. Current limitations of volumetric capnography in surfactant-depleted small lungs. Pediatr Crit Care Med. 2004 Jan;5(1):75-80. doi: 10.1097/01.PCC.0000102384.60676.E5.
PMID: 14697113BACKGROUNDKugelman A, Golan A, Riskin A, Shoris I, Ronen M, Qumqam N, Bader D, Bromiker R. Impact of Continuous Capnography in Ventilated Neonates: A Randomized, Multicenter Study. J Pediatr. 2016 Jan;168:56-61.e2. doi: 10.1016/j.jpeds.2015.09.051. Epub 2015 Oct 17.
PMID: 26490126BACKGROUNDKugelman A, Zeiger-Aginsky D, Bader D, Shoris I, Riskin A. A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2. Pediatrics. 2008 Dec;122(6):e1219-24. doi: 10.1542/peds.2008-1300. Epub 2008 Nov 24.
PMID: 19029196BACKGROUNDCassady G. Transcutaneous monitoring in the newborn infant. J Pediatr. 1983 Dec;103(6):837-48. doi: 10.1016/s0022-3476(83)80698-2. No abstract available.
PMID: 6417293BACKGROUNDRennie JM. Transcutaneous carbon dioxide monitoring. Arch Dis Child. 1990 Apr;65(4 Spec No):345-6. doi: 10.1136/adc.65.4_spec_no.345. No abstract available.
PMID: 2110802BACKGROUNDBendjelid K, Schutz N, Stotz M, Gerard I, Suter PM, Romand JA. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor. Crit Care Med. 2005 Oct;33(10):2203-6. doi: 10.1097/01.ccm.0000181734.26070.26.
PMID: 16215371BACKGROUNDDullenkopf A, Bernardo SD, Berger F, Fasnacht M, Gerber AC, Weiss M. Evaluation of a new combined SpO2/PtcCO2 sensor in anaesthetized paediatric patients. Paediatr Anaesth. 2003 Nov;13(9):777-84. doi: 10.1046/j.1460-9592.2003.01146.x.
PMID: 14617118BACKGROUNDSorensen LC, Brage-Andersen L, Greisen G. Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension. Scand J Clin Lab Invest. 2011 Nov;71(7):548-52. doi: 10.3109/00365513.2011.590601. Epub 2011 Jul 6.
PMID: 21732731BACKGROUNDEberhard P. The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions. Anesth Analg. 2007 Dec;105(6 Suppl):S48-S52. doi: 10.1213/01.ane.0000278642.16117.f8.
PMID: 18048898BACKGROUNDHirata K, Nishihara M, Oshima Y, Hirano S, Kitajima H. Application of transcutaneous carbon dioxide tension monitoring with low electrode temperatures in premature infants in the early postnatal period. Am J Perinatol. 2014 May;31(5):435-40. doi: 10.1055/s-0033-1352485. Epub 2013 Aug 5.
PMID: 23918520BACKGROUNDAly S, El-Dib M, Mohamed M, Aly H. Transcutaneous Carbon Dioxide Monitoring with Reduced-Temperature Probes in Very Low Birth Weight Infants. Am J Perinatol. 2017 Apr;34(5):480-485. doi: 10.1055/s-0036-1593352. Epub 2016 Sep 27.
PMID: 27673754BACKGROUNDKarlsson V, Sporre B, Agren J. Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible. Anesth Analg. 2016 Oct;123(4):1004-7. doi: 10.1213/ANE.0000000000001462.
PMID: 27464976BACKGROUNDRestrepo RD, Hirst KR, Wittnebel L, Wettstein R. AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012. Respir Care. 2012 Nov;57(11):1955-62. doi: 10.4187/respcare.02011.
PMID: 23107301BACKGROUNDSivan Y, Eldadah MK, Cheah TE, Newth CJ. Estimation of arterial carbon dioxide by end-tidal and transcutaneous PCO2 measurements in ventilated children. Pediatr Pulmonol. 1992 Mar;12(3):153-7. doi: 10.1002/ppul.1950120305.
PMID: 1641271BACKGROUNDTobias JD, Meyer DJ. Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide. Anesth Analg. 1997 Jul;85(1):55-8. doi: 10.1097/00000539-199707000-00010.
PMID: 9212122BACKGROUNDTingay DG, Stewart MJ, Morley CJ. Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport. Arch Dis Child Fetal Neonatal Ed. 2005 Nov;90(6):F523-6. doi: 10.1136/adc.2004.064717. Epub 2005 Apr 29.
PMID: 15863489BACKGROUNDTingay DG, Mun KS, Perkins EJ. End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates. Arch Dis Child Fetal Neonatal Ed. 2013 Mar;98(2):F161-4. doi: 10.1136/fetalneonatal-2011-301606. Epub 2012 Aug 11.
PMID: 22887048BACKGROUNDvan Kaam AH, De Jaegere AP, Rimensberger PC; Neovent Study Group. Incidence of hypo- and hyper-capnia in a cross-sectional European cohort of ventilated newborn infants. Arch Dis Child Fetal Neonatal Ed. 2013 Jul;98(4):F323-6. doi: 10.1136/archdischild-2012-302649. Epub 2012 Dec 14.
PMID: 23241364BACKGROUNDDonner A, Eliasziw M. Sample size requirements for reliability studies. Stat Med. 1987 Jun;6(4):441-8. doi: 10.1002/sim.4780060404.
PMID: 3629046BACKGROUNDMuller R, Buttner P. A critical discussion of intraclass correlation coefficients. Stat Med. 1994 Dec 15-30;13(23-24):2465-76. doi: 10.1002/sim.4780132310.
PMID: 7701147BACKGROUNDWalter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med. 1998 Jan 15;17(1):101-10. doi: 10.1002/(sici)1097-0258(19980115)17:13.0.co;2-e.
PMID: 9463853BACKGROUNDMcSwain SD, Hamel DS, Smith PB, Gentile MA, Srinivasan S, Meliones JN, Cheifetz IM. End-tidal and arterial carbon dioxide measurements correlate across all levels of physiologic dead space. Respir Care. 2010 Mar;55(3):288-93.
PMID: 20196877BACKGROUNDSiobal MS. Monitoring Exhaled Carbon Dioxide. Respir Care. 2016 Oct;61(10):1397-416. doi: 10.4187/respcare.04919. Epub 2016 Sep 6.
PMID: 27601718BACKGROUNDFayoux P, Devisme L, Merrot O, Marciniak B. Determination of endotracheal tube size in a perinatal population: an anatomical and experimental study. Anesthesiology. 2006 May;104(5):954-60. doi: 10.1097/00000542-200605000-00011.
PMID: 16645447BACKGROUNDYildizdas D, Yapicioglu H, Yilmaz HL, Sertdemir Y. Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit. Arch Dis Child. 2004 Feb;89(2):176-80. doi: 10.1136/adc.2002.016261.
PMID: 14736638BACKGROUNDZavorsky GS, Cao J, Mayo NE, Gabbay R, Murias JM. Arterial versus capillary blood gases: a meta-analysis. Respir Physiol Neurobiol. 2007 Mar 15;155(3):268-79. doi: 10.1016/j.resp.2006.07.002. Epub 2006 Aug 17.
PMID: 16919507BACKGROUNDBland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571-82. doi: 10.1080/10543400701329422.
PMID: 17613642BACKGROUNDWerther T, Aichhorn L, Stellberg S, Cardona FS, Klebermass-Schrehof K, Berger A, Schmolzer GM, Wagner M. Monitoring of carbon dioxide in ventilated neonates: a prospective observational study. Arch Dis Child Fetal Neonatal Ed. 2022 May;107(3):293-298. doi: 10.1136/archdischild-2021-322138. Epub 2021 Aug 3.
PMID: 34344835DERIVED
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Tobias Werther, PhD
Medical University Vienna
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR INVESTIGATOR
- PI Title
- Dr.
Study Record Dates
First Submitted
November 26, 2018
First Posted
November 29, 2018
Study Start
November 1, 2018
Primary Completion
September 26, 2020
Study Completion
September 30, 2020
Last Updated
August 17, 2021
Record last verified: 2021-08