The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
1 other identifier
interventional
106
1 country
1
Brief Summary
Since the laryngeal mask airway (LMA) was designed and introduced into a clinical setting, a supraglottic airway device is widely used because it has advantages such as manipulation of the device when inserting it is easier than that of an endotracheal tube and it causes less postoperative sore throats. Insertion of an LMA can be performed relatively easily and safety at an appropriate depth of anesthesia when compared with the insertion of an endotracheal tube because an LMA is inserted without using a laryngoscope and without causing stimulus to the vocal cords and the trachea. Hence, an LMA may be useful in cases of coronary artery disease and a carotid endarectomy where stabilization of the cardiopulmonary function is important. In addition, an LMA is hemodynamically stable not only in the induction of anesthesia but also in the arousal of anesthesia and thus less dangerous to a cardiovascular disease patient. LMA may be useful also to patients having chronic obstructive lung disease because the patients have an excessively sensitive airway and ventilation is difficult to perform in them. Therefore, in elderly patients having a prevalence for cardiovascular disease or chronic obstructive lung disease, use of an LMA, which stimulates the airway less, may provide hemodynamical stability and reduce relevant complications or side effects. LMA Supreme which is newly designed in such ways has been proven to be superior to the conventional LMA Classic in terms of easy insertion and oropharyngeal sealing. A study which compared LMA Classic and LMA Supreme with adult subjects showed that LMA Supreme had a superior insertion success rate and better oropharyngeal leak pressure (OLP) than those of LMA Classic. Another newly developed supraglottic airway device is I-gel. In I-gel, which is a disposable, latex-free LMA, a soft, gel-type cuff made of a thermoplastic elastomer replaces the inflatable cuff of other LMAs. Thus, I-gel has an advantage that, once it is installed, it requires no additional clinical manipulation such as cuff inflation or cuff pressure monitoring. A comparison of I-gel with LMA Classic and other disposable supraglottic airway devices produced by various manufactures in adult subjects showed that the clinical properties were similar with respect to easy insertion, time required for installation, laryngopharynx leak pressure, and degree of glottis exposure observed with a fiberoptic bronchoscope. Thus, I-gel is expected to be a supraglottic airway device which may replace the conventional LMA Classic. The elderly are known to have an upper airway anatomically different from that of younger adults depending on age. A study conducted with CT showed that normal elderly people had a wider upper airway than that of younger males or middle-aged males and that elderly with accompanying sleep apnea had a wider upper airway than that of younger males in all regions including the nasopharynx, oropharynx, and hypopharynx. Therefore, because the upper airway of the elderly is wider and longer, a different supraglottic airway device guide may be necessary. Our previous studies showed that the single time success rate was significantly lower, the insertion was more difficult, and the insertion took a longer time when the LMA classic was used in elderly patients than in younger adult patients. However, there is no available guide for the use of a supraglottic airway device or for a supraglottic airway device more appropriate for elderly patients. Moreover, no study has been ever conducted with regard to such a guide. Therefore, in this study, the clinical usefulness of I-gel and LMA Supreme, which are the newest supraglottic airway devices, was verified in elderly patients. It was also verified which of the two devices is better to use as a supraglottic airway device.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Dec 2013
Typical duration for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
December 1, 2013
CompletedFirst Submitted
Initial submission to the registry
December 18, 2013
CompletedFirst Posted
Study publicly available on registry
January 3, 2014
CompletedPrimary Completion
Last participant's last visit for primary outcome
October 1, 2016
CompletedStudy Completion
Last participant's last visit for all outcomes
October 1, 2016
CompletedNovember 3, 2016
November 1, 2016
2.8 years
December 18, 2013
November 2, 2016
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
The success insertion rate of supraglottic airway devices of the first trial was the primary end point.
The success insertion rate of supraglottic airway devices of the first trial was the primary end point. In success insertion of supraglottic airway devices is confirmed by following cases of manual ventilation. 1. Appropriateness of the chest wall movement 2. A square wave in the capnograph 3. The time taken until the successful installation of an LMA
Average 10 seconds after induction and during average 10 mins
Study Arms (2)
The clinical efficacy of the I-gel
EXPERIMENTALThe clinical efficacy of the I-gel
The clinical efficacy Supreme-LMA
ACTIVE COMPARATORThe clinical efficacy Supreme-LMA
Interventions
* The patient was monitored at 1-5 minute intervals. * While supplying oxygen through a mask, propofol 1.0mg/kg and remifentanil 0.5ug/kg were intravenously injected to induce anesthesia. When consciousness was not lost, propofol 0.5mg/kg was additionally injected. After consciousness was lost and spontaneous respiration disappeared, rocuronium 0.3 mg/kg was intravenously injected while performing manual ventilation. * After injecting an anesthetic and muscle relaxant, the injection concentration of fresh gas including 6 L/min oxygen and desflurane was regulated to maintain BIS between 40 and 60. A train of four (TOF) was performed with a nerve stimulator for muscle relaxation monitoring to verify that a muscular contraction did not take place (TOF=0). * Then, with the assistance of another anesthesiologist, I-gel prepared in advance was inserted.
* The patient was monitored at 1-5 minute intervals. * While supplying oxygen through a mask, propofol 1.0mg/kg and remifentanil 0.5ug/kg were intravenously injected to induce anesthesia. When consciousness was not lost, propofol 0.5mg/kg was additionally injected. After consciousness was lost and spontaneous respiration disappeared, rocuronium 0.3 mg/kg was intravenously injected while performing manual ventilation. * After injecting an anesthetic and muscle relaxant, the injection concentration of fresh gas including 6 L/min oxygen and desflurane was regulated to maintain BIS between 40 and 60. A train of four (TOF) was performed with a nerve stimulator for muscle relaxation monitoring to verify that a muscular contraction did not take place (TOF=0). * Then, with the assistance of another anesthesiologist, Supreme LMA prepared in advance was inserted.
Eligibility Criteria
You may qualify if:
- The elderly patients aged between 65 and 85
- The patient having a plan for a regular operation under general anesthesia in which the expected operation duration is within two hours and the airway may be managed intraoperatively with a supraglottic airway device.
You may not qualify if:
- The patients having an anatomical structure which may cause difficulty in mask respiration
- The patients having an upper airway infection or an airway-related disease such as asthma and pneumonia.
- The patients having a risk of aspiration such as gastroesophageal reflux.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Department of Anesthesiology and Pain Medicine, Severance Hospital, Yonsei University Health System
Seoul, 120-752, South Korea
Related Publications (1)
Kim MH, Lee JH, Choi YS, Park S, Shin S. Comparison of the laryngeal mask airway supreme and the i-gel in paralysed elderly patients: A randomised controlled trial. Eur J Anaesthesiol. 2018 Aug;35(8):598-604. doi: 10.1097/EJA.0000000000000700.
PMID: 28857785DERIVED
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
December 18, 2013
First Posted
January 3, 2014
Study Start
December 1, 2013
Primary Completion
October 1, 2016
Study Completion
October 1, 2016
Last Updated
November 3, 2016
Record last verified: 2016-11