Comparison of DCT, ORA and GAT in Eyes After Penetrating Keratoplasty
Comparison of Pascal Dynamic Contour Tonometer, Reichart Ocular Response Analyzer and Goldmann Applanation Tonometer in Eyes After Penetrating Keratoplasty
1 other identifier
observational
35
1 country
2
Brief Summary
To compare intraocular pressure (IOP) measured by the Reichert Ocular Response Analyzer (ORA), Pascal dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT) in eyes after Penetrating Keratoplasty (KPL)
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started May 2009
Shorter than P25 for all trials
2 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 2, 2009
CompletedFirst Posted
Study publicly available on registry
February 3, 2009
CompletedStudy Start
First participant enrolled
May 1, 2009
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 1, 2009
CompletedStudy Completion
Last participant's last visit for all outcomes
May 1, 2010
CompletedSeptember 15, 2009
September 1, 2009
7 months
February 2, 2009
September 13, 2009
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Intra ocular pressure
1 year
Secondary Outcomes (1)
Corneal compensated intra ocular pressure, Corneal hysteresis, Corneal resistance factor
1 year
Study Arms (1)
IOP
Measuring IOP
Interventions
Eligibility Criteria
Patients post keratoplasty surgery
You may qualify if:
- Eyes after KPL surgery at the Goldschleger Eye Institute in the last 10 years.
You may not qualify if:
- Uncooperative subjects for whom good quality results are unattainable.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (2)
Goldschleger eye institute, Sheba medical center
Ramat Gan, Israel
The Goldschleger eye institute, Sheba Medical Center, Tel Aviv University
Ramat Gan, Israel
Related Publications (9)
Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006 May;141(5):868-75. doi: 10.1016/j.ajo.2005.12.007. Epub 2006 Mar 9.
PMID: 16527231BACKGROUNDJain AK, Saini JS, Gupta R. Tonometry in normal and scarred corneas, and in postkeratoplasty eyes: a comparative study of the Goldmann, the ProTon and the Schiotz tonometers. Indian J Ophthalmol. 2000 Mar;48(1):25-32.
PMID: 11271930BACKGROUNDKerautret J, Colin J, Touboul D, Roberts C. Biomechanical characteristics of the ectatic cornea. J Cataract Refract Surg. 2008 Mar;34(3):510-3. doi: 10.1016/j.jcrs.2007.11.018.
PMID: 18299080BACKGROUNDLuce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005 Jan;31(1):156-62. doi: 10.1016/j.jcrs.2004.10.044.
PMID: 15721708BACKGROUNDMedeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006 Oct;15(5):364-70. doi: 10.1097/01.ijg.0000212268.42606.97.
PMID: 16988597BACKGROUNDMollan SP, Wolffsohn JS, Nessim M, Laiquzzaman M, Sivakumar S, Hartley S, Shah S. Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Br J Ophthalmol. 2008 Dec;92(12):1661-5. doi: 10.1136/bjo.2007.136473. Epub 2008 Aug 29.
PMID: 18757471BACKGROUNDPandav SS, Sharma A, Gupta A, Sharma SK, Gupta A, Patnaik B. Reliability of proton and goldmann applanation tonometers in normal and postkeratoplasty eyes. Ophthalmology. 2002 May;109(5):979-84. doi: 10.1016/s0161-6420(02)00974-0.
PMID: 11986107BACKGROUNDRao VJ, Gnanaraj L, Mitchell KW, Figueiredo FC. Clinical comparison of ocular blood flow tonometer, Tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes. Cornea. 2001 Nov;20(8):834-8. doi: 10.1097/00003226-200111000-00011.
PMID: 11685061BACKGROUNDTouboul D, Roberts C, Kerautret J, Garra C, Maurice-Tison S, Saubusse E, Colin J. Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry. J Cataract Refract Surg. 2008 Apr;34(4):616-22. doi: 10.1016/j.jcrs.2007.11.051.
PMID: 18361984BACKGROUND
Study Officials
- STUDY CHAIR
Shlomo Melamed, Prof
Sheba medical center, head of Sam rotberg glaucoma center
Central Study Contacts
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER GOV
Study Record Dates
First Submitted
February 2, 2009
First Posted
February 3, 2009
Study Start
May 1, 2009
Primary Completion
December 1, 2009
Study Completion
May 1, 2010
Last Updated
September 15, 2009
Record last verified: 2009-09