Predicting Response to Cardiac Resynchronization Therapy in Heart Failure
2 other identifiers
observational
180
1 country
3
Brief Summary
This study will explore which characteristics of patients with heart failure will likely predict improvement after cardiac resynchronization (CRT), implantation of a pacemaker to improve heart function. In spite of major medical advances, about 30% to 40% of patients with heart failure do not respond to CRT, and the reasons are not well understood. This study will involve magnetic resonance imaging (MRI), electrocardiogram (ECG), and echocardiography techniques to let researchers examine what may influence response to CRT. Patients ages 18 and older with a left ventricular disorder and who are not pregnant or breastfeeding may be eligible for this study. Initial evaluation will take 5 to 6 hours. A blood sample of about 2 tablespoons will be collected, and several procedures will be performed. MRI uses a strong magnetic field and radio waves to obtain images of body organs and tissues. For that procedure, patients will lie on a table that slides into the enclosed tunnel of the scanner and be asked to lie still. They will be in the scanner for 30 to 90 minutes. As the scanner takes pictures, patients will hear knocking sounds, and they may be asked to hold their breath intermittently for 5 to 20 seconds. During part of the scan, a drug called gadolinium will be given intravenously (IV), to make the heart easier to see. Patients will be able to communicate with the MRI staff at all times during the scan. At any time, patients may ask to be moved out of the machine. Patients having metal in their body that interferes with the MRI scanner should not have this test. During the procedure, an ECG machine will monitor the heart, through wires connected to pads on the skin. Patients will have an echocardiogram, in which sound waves look at the heart. A small handheld probe will touch the chest and abdomen, and an IV tube may be inserted to inject a contrast drug to improve the quality of heart images. Patients will have a cardiopulmonary stress test (treadmill test) and a 6-minute walk test, both before pacemaker implantation and then 6 months afterward. Also before and after pacemaker implantation, patients will complete the Minnesota Living with Heart Failure Questionnaire, regarding the impact of heart failure on patients' lives. The follow-up visit will take 3 to 4 hours.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for all trials
Started Jul 2006
Shorter than P25 for all trials
3 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
July 28, 2006
CompletedFirst Submitted
Initial submission to the registry
August 1, 2006
CompletedFirst Posted
Study publicly available on registry
August 2, 2006
CompletedStudy Completion
Last participant's last visit for all outcomes
May 29, 2007
CompletedJuly 2, 2017
May 29, 2007
August 1, 2006
June 30, 2017
Conditions
Keywords
Eligibility Criteria
You may not qualify if:
- No one will be excluded from this study based on race, gender, and ethnicity.
- LV dysfunction with an LV ejection fraction less than or equal to 35% (by clinical echocardiography, cardiac catheterization, radionuclide ventriculography, or MRI).
- New York Heart Association (NYHA) class III or IV functional status
- QRS interval greater than or equal to 120msec (measured on clinical ECG)
- Optimal pharmacological therapy for heart failure with at least 1 month on an ACE-inhibitor or angiotensin II receptor blocker (ARB) and if on a beta blocker, 3 months on a stable dose of a beta blocker. Patients need to be taking their medicines consistently to be enrolled in this study.
- Coronary artery bypass graft surgery or percutaneous coronary intervention within 60 days of enrollment.
- Chronic medically refractory atrial tachyarrhythmias
- History of medical non-compliance
- Women who are pregnant or not using medically acceptable birth control (since the x-rays used to guide pacemaker therapy may increase the risk to the fetus and the fetal risks of gadolinium are not well known).
- Contraindication to MRI scanning including patients with the following devices:
- i. Central nervous system aneurysm clips
- ii. Implanted neural stimulator
- iii. Implanted cardiac pacemaker or defibrillator prior to enrollment
- iv. Cochlear implant
- v. Ocular foreign body (e.g. metal shavings)
- +10 more criteria
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (3)
Mid-Atlantic Associates
Baltimore, Maryland, United States
Suburban Hospital
Bethesda, Maryland, 20814, United States
National Heart, Lung and Blood Institute (NHLBI), 9000 Rockville Pike
Bethesda, Maryland, 20892, United States
Related Publications (1)
Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, Ellestad M, Trupp RJ, Underwood J, Pickering F, Truex C, McAtee P, Messenger J; MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002 Jun 13;346(24):1845-53. doi: 10.1056/NEJMoa013168.
PMID: 12063368BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Design
- Study Type
- observational
- Sponsor Type
- NIH
Study Record Dates
First Submitted
August 1, 2006
First Posted
August 2, 2006
Study Start
July 28, 2006
Study Completion
May 29, 2007
Last Updated
July 2, 2017
Record last verified: 2007-05-29