NCT07850570

Brief Summary

Mandibular fractures represent a significant portion of maxillofacial trauma, primarily resulting from motor vehicle accidents, interpersonal violence, and sports-related injuries 1. Achieving successful treatment requires accurate anatomical reduction, stable internal fixation, and restoration of pre-traumatic occlusion and masticatory function 2. Open reduction and internal fixation (ORIF) using titanium miniplates has long served as the gold standard for mandibular fracture management due to their superior mechanical strength, excellent biocompatibility, and proven structural reliability 3. Despite their widespread clinical adoption, conventional titanium plates present notable drawbacks. Their high elastic modulus compared to human cortical bone often leads to stress shielding, which can impede normal bone healing and cause local osteopenia 4.Additionally, titanium hardware can cause temperature sensitivity, scatter artifacts on computed tomography (CT) and magnetic resonance imaging (MRI) scans, and may necessitate secondary surgical removal due to palpability or infection 5. To address these limitations, Polyether Ether Ketone (PEEK)-a high-performance thermoplastic polymer has emerged as a promising alternative biomaterial in maxillofacial surgery. PEEK exhibits an elastic modulus close to natural bone, thereby reducing stress shielding and promoting physiological strain distribution during fracture healing 6. Furthermore, PEEK is radiolucent, non-magnetic, and chemically inert, allowing artifact-free postoperative radiologic assessment 7. With advancements in digital dentistry, computer-aided design and computer-aided manufacturing (CAD/CAM) alongside 3D printing have enabled the fabrication of patient-specific, custom-made implants. Custom-made titanium and PEEK plates eliminate the need for intraoperative manual bending, significantly reducing surgical time, improving contour accuracy, and enhancing mechanical stability across the fracture site 8. While custom-made titanium provides rigid fixation suitable for high-load zones, custom-made PEEK implants offer an biomechanically compatible and artifact-free alternative. However, direct comparative clinical and biomechanical evaluations between custom-made titanium and custom-made PEEK plates for mandibular fracture fixation remain limited. Therefore, this study aimed to evaluate and compare the clinical outcome, stability, and surgical efficiency of custom-made titanium versus custom-made PEEK plates in the fixation of mandibular fractures.

Trial Health

63
Monitor

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
32

participants targeted

Target at P25-P50 for not_applicable

Timeline
24mo left

Started Sep 2026

Typical duration for not_applicable

Geographic Reach
1 country

1 active site

Status
not yet recruiting

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Progress1%
Sep 2026Sep 2028

First Submitted

Initial submission to the registry

September 23, 2026

Completed
1 day until next milestone

Study Start

First participant enrolled

September 24, 2026

Completed
6 days until next milestone

First Posted

Study publicly available on registry

September 30, 2026

Completed
6 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

March 24, 2027

Expected
1.5 years until next milestone

Study Completion

Last participant's last visit for all outcomes

September 24, 2028

Last Updated

September 30, 2026

Status Verified

September 1, 2026

Enrollment Period

6 months

First QC Date

September 23, 2026

Last Update Submit

September 23, 2026

Conditions

Keywords

PEEK plates-Titanium plates-mandibular fracture

Outcome Measures

Primary Outcomes (1)

  • The adequacy of the reduction of the fractured segment

    will be determined by an assessment of the inferior border of the mandible as follows: 1. Excellent reduction: whenever alignment of the inferior border of mandible will be maintained across the fracture line. 2. Good reduction: if a discrepancy of 1-3 mm is noted. 3. Fair reduction: if a discrepancy of 3-5mm is noted. 4. Poor reduction: if the discrepancy is \> 5 mm.

    immediately and 6 months after the surgery consequently

Study Arms (2)

Custom-Made Titanium Plate

EXPERIMENTAL

Custom-Made Titanium Plate for Fixation of Mandibular Fractures

Device: Custom-Made Titanium Plate

Custom-Made PEEK Plate

EXPERIMENTAL

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

Device: Custom-Made PEEK Plate

Interventions

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

Custom-Made PEEK Plate

Custom-made titanium plate used for fixation of mandibular fractures.

Custom-Made Titanium Plate

Eligibility Criteria

Age18 Years - 50 Years
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64)

You may qualify if:

  • \) Patients age ranging from 18 to 50 years. 2) Unilateral and/or bilateral simple or compound fractures of the mandibular symphysis, parasymphysis or body regions that are displaced and require open reduction with internal fixation.
  • \) The fractures must be recent, having occurred no longer than 10 days prior to the surgical treatment.
  • \) Healthy patients who are classified according to the American Society of Anesthesiologists (ASA) physical status classification as class I.

You may not qualify if:

  • \) Patients suffer from pathological fractures. 2) Comminuted and infected fractures. 3) Fracture of the atrophic edentulous ridge 4) Old mandibular fractures (more than 10 days). 5) Patients with ASA classes II, III, IV, and V.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Mansoura University, Faculty of Dentistry

Al Mansurah, Dakahlia Governorate, 35516, Egypt

Location

MeSH Terms

Conditions

Mandibular Fractures

Condition Hierarchy (Ancestors)

Jaw FracturesMaxillofacial InjuriesFacial InjuriesCraniocerebral TraumaTrauma, Nervous SystemNervous System DiseasesSkull FracturesFractures, BoneWounds and Injuries

Study Officials

  • Aya ali Elsies, assistant lecturer

    Faculty of Dentistry, Mansoura University

    PRINCIPAL INVESTIGATOR

Central Study Contacts

aya ali Elsies, assistant lecturer

CONTACT

mahmoud hamdy sediek, doctor

CONTACT

Study Design

Study Type
interventional
Phase
not applicable
Allocation
RANDOMIZED
Masking
NONE
Purpose
TREATMENT
Intervention Model
PARALLEL
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

September 23, 2026

First Posted

September 30, 2026

Study Start

September 24, 2026

Primary Completion (Estimated)

March 24, 2027

Study Completion (Estimated)

September 24, 2028

Last Updated

September 30, 2026

Record last verified: 2026-09

Data Sharing

IPD Sharing
Will not share

Locations