Posture, Interface, and Peak Cough Flow
PCF P/I
Body Posture and Interface Effects on Peak Cough Flow in Healthy Adults: A Randomized Crossover Study
1 other identifier
interventional
24
1 country
1
Brief Summary
Cough is a key airway protective mechanism requiring coordinated neuromuscular function. Peak cough flow (PCF) is a simple, non-invasive measure widely used to assess cough effectiveness and guide clinical decisions. Current ATS/ERS guidelines recommend measuring PCF in a seated position using a mouthpiece with a nose clip; however, this setup is not always feasible in clinical practice. Some patients cannot maintain posture or ensure an adequate mouthpiece seal, making a facial mask a potential alternative. The influence of body position and interface on PCF measurements remains unclear, with limited evidence from randomized crossover studies. This study aims to evaluate the effects of body position (sitting vs standing) and measurement interface (mouthpiece vs facial mask) on PCF in healthy young adults. In a randomized within-subject crossover design, participants perform PCF measurements under four conditions (Sit-Mask, Stand-Mask, Sit-Mouthpiece, Stand-Mouthpiece) during a single session. The findings will help inform more flexible and standardized PCF assessment procedures in clinical practice.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started May 2024
Typical duration for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
May 1, 2024
CompletedPrimary Completion
Last participant's last visit for primary outcome
August 31, 2024
CompletedFirst Submitted
Initial submission to the registry
May 21, 2026
CompletedStudy Completion
Last participant's last visit for all outcomes
May 21, 2026
CompletedFirst Posted
Study publicly available on registry
June 8, 2026
CompletedJune 8, 2026
June 1, 2026
4 months
May 21, 2026
June 1, 2026
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Peak cough Flow (PCF)
PCF measurement in L/s
Day 1
Study Arms (4)
Sit-Mask
ACTIVE COMPARATORStand-Mask
ACTIVE COMPARATORSit-Mouthpiece
ACTIVE COMPARATORStand-Mouthpiece
ACTIVE COMPARATORInterventions
Peak cough flow measured in the seated position. The facial mask (V2 Mask™, Hans Rudolph, Inc., Kansas, USA; size fitted to participant) was connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter. Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Peak cough flow measured in the seated position. The mouthpiece (Pulmosafe, Lemon Medical GmbH, Hammelburg, Germany) was used with a nose clip and connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter. Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Eligibility Criteria
You may qualify if:
- Healthy adults aged 20 to 30 years
- Non-smoker
- Self-reported good health status
- Able to perform all four randomized cough conditions
You may not qualify if:
- Any chronic disease
- Signs of airway obstruction on clinical examination
- Auscultatory abnormalities (wheezing or stridor) prior to testing
- Incomplete participation in all four conditions
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Cliniques universitaires Saint-Luc
Brussels, 1180, Belgium
Related Publications (2)
Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J; ATS/ERS Task Force. Standardisation of spirometry. Eur Respir J. 2005 Aug;26(2):319-38. doi: 10.1183/09031936.05.00034805. No abstract available.
PMID: 16055882BACKGROUNDBrennan M, McDonnell MJ, Duignan N, Gargoum F, Rutherford RM. The use of cough peak flow in the assessment of respiratory function in clinical practice- A narrative literature review. Respir Med. 2022 Mar;193:106740. doi: 10.1016/j.rmed.2022.106740. Epub 2022 Jan 15.
PMID: 35123355BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Purpose
- OTHER
- Intervention Model
- CROSSOVER
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- PT, PhD
Study Record Dates
First Submitted
May 21, 2026
First Posted
June 8, 2026
Study Start
May 1, 2024
Primary Completion
August 31, 2024
Study Completion
May 21, 2026
Last Updated
June 8, 2026
Record last verified: 2026-06
Data Sharing
- IPD Sharing
- Will not share