Robotic Transjugular Transcatheter Tricuspid Valve Replacement
Robotic Lux
1 other identifier
interventional
10
1 country
1
Brief Summary
Valvular heart disease (VHD), caused by abnormalities in heart valves, can lead to severe complications such as heart failure and death, with approximately 220 million affected patients worldwide. The prevalence of VHD continues to grow alongside the aging global population. Transcatheter heart valve interventions have emerged as minimally invasive alternatives, offering benefits like shorter recovery times and reduced discomfort. However, current manual catheter-based techniques are complex, highly dependent on clinicians' expertise, and involve significant physical risk due to prolonged exposure to X-ray radiation and cumbersome protective gear. To address these challenges, a novel, universal intracardiac robotic system is proposed to improve precision, safety, and procedural efficiency. This system integrates a high-dexterity, load-capacity catheter instrument, a modular concentric robotic platform, and an augmented reality (AR) navigation interface. The catheter's design balances flexibility for navigating complex intracardiac paths with the rigidity needed for device deployment. The robotic platform's modular architecture enhances versatility, enabling control across various procedures and anatomical variations, while the AR system facilitates intuitive preoperative planning and real-time intraoperative guidance through multimodal image fusion. The core innovation lies in overcoming existing limitations: balancing catheter flexibility and load capacity, expanding robotic system adaptability for different valve procedures, and improving integration with imaging modalities like computed tomography, transesophageal echocardiogram, and fluoroscopy. The project aims to develop sophisticated models for instrument design, control strategies for multi-instrument coordination, and advanced navigation tools. These technological advancements are intended to elevate the clinical utility of robotic intracardiac interventions, making them safer, more efficient, and easier to adopt widely. By establishing a systematic approach for intelligent, multimodal, robotic-assisted valvular procedures, this work promises significant contributions to minimally invasive cardiology and holds substantial potential for clinical translation.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Mar 2026
Typical duration for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
March 12, 2026
CompletedFirst Submitted
Initial submission to the registry
March 31, 2026
CompletedFirst Posted
Study publicly available on registry
April 7, 2026
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 30, 2027
ExpectedStudy Completion
Last participant's last visit for all outcomes
March 31, 2028
September 18, 2026
September 1, 2026
1.6 years
March 31, 2026
September 15, 2026
Conditions
Keywords
Outcome Measures
Primary Outcomes (10)
Rate of Intraprocedural success according to TVARC
TVARC intra-procedural success is defined as: 1. Absence of intraprocedural mortality or stroke; and 2. Successful access, delivery, and retrieval of the device delivery system; and 3. Successful deployment and correct positioning of the intended device(s) without requiring implantation of unplanned additional devices; and 4. Adequate performance of the transcatheter device. Performance of devices whose purpose is a reduction in TR, should include the absence of tricuspid stenosis (TVA \>1.5 cm 2 and mean gradient \<5 mm Hg); reduction of total tricuspid regurgitation to optimal (\<= mild) or acceptable (\<=moderate). 5. Absence of device-related obstruction of forward flow 6. Absence of device-related pulmonary embolism 7. Freedom from emergency surgery or reintervention during the first 24 h related to the device or access procedure
Intra-operation
Rate of major adverse events: cardiovascular mortality
rate of cardiovascular mortality at 30 days post-operation
30 day post-operation
Rate of major adverse events: myocardial infarction
rate of myocardial infarction at 30 days post-operation
30 day post-operation
Rate of major adverse events: stroke
rate of stroke at 30 days post-operation
30 day post-operation
Rate of major adverse events: renal complication
Rate of renal complications requiring unplanned dialysis or renal replacement therapy at 30 days post-operation
30 day post-operation
Rate of major adverse events: severe bleeding
rate of severe bleeding at 30 days post-operation
30 day post-operation
Rate of major adverse events: nonelective Tricuspid Valve reintervention
rate of nonelective Tricuspid Valve reintervention at 30 days post-operation
30 day post-operation
Rate of major adverse events: major vascular complications
rate of major vascular complications at 30 days post-operation
30 day post-operation
Rate of major adverse events: major cardiac structural complications
rate of major cardiac structural complications at 30 days post-operation
30 day post-operation
Rate of major adverse events: device-related pulmonary embolism
rate of device-related pulmonary embolism at 30 days post-operation
30 day post-operation
Secondary Outcomes (13)
Device success rate
intra-operation
Operation duration
intra-operation
Overall Procedural Time
intra-operation
Fluoroscopy Time
intra-operation
Radiation Dose to Primary Operator
immediately post-operation
- +8 more secondary outcomes
Study Arms (1)
Intervention
EXPERIMENTALInterventions
Recent advancements in transcatheter therapies have demonstrated promising outcomes for patients with tricuspid valve disease, with transcatheter tricuspid valve replacement (TTVR) emerging as a viable alternative to surgical intervention. The Lux Valve Plus system represents a novel transjugular transcatheter tricuspid valve replacement platform designed to address the unique anatomical challenges of the tricuspid valve. Its transjugular design is advantageous for valve alignment; however, this access route is ergonomically unfavourable for the implanter, increasing radiation exposure compared to a transfemoral approach. Integrating robotic-assisted technology into this platform could potentially reduce radiation exposure, improve ergonomics for operators, and facilitate accurate valve delivery. This research aims to explore the feasibility of robotic transjugular TTVR using the Lux Valve Plus system.
Eligibility Criteria
You may qualify if:
- Age 18-90
- Severe symptomatic TR
- Deem high risk for tricuspid valve surgery determined by a multidisciplinary heart team (including cardiologists, cardiac surgeons and cardiac anesthetists) and
- Anatomically feasible for transjugular transcatheter tricuspid valve replacement using the Lux-valve plus system
- Able to consent
You may not qualify if:
- Prior TV repair or replacement that would interfere with Lux-valve plus implantation
- severe pulmonary hypertension (pulmonary artery systolic pressure \>70 mm Hg or \>2/3 systemic with pulmonary vascular resistance \>5 WU after vasodilator challenge)
- Pregnant or nursing patients and those who plan pregnancy during the study period. Female patients of childbearing potential must have a negative pregnancy
- Left Ventricular Ejection Fraction (LVEF) \<40% or;
- Evidence of intracardiac mass, thrombus or vegetation or;
- Anatomical structures precluding proper device deployment or device vascular access, evaluated by echo or CT or;
- Surgical correction is indicated for other concomitant valvular disease (e.g., severe aortic, mitral and/or pulmonic valve stenosis and/or regurgitation); Subjects with concomitant valvular disease may treat their respective valve first and wait 2 months before being reassessed for the trial.
- Sepsis or active endocarditis within 3 months, or infections requiring antibiotic therapy within 2 weeks prior to the planned procedure or;
- Active peptic ulcer or active gastrointestinal (GI) bleeding precluding anticoagulation or antiplatelet therapy or;
- Underwent any cardiac or non-cardiac interventional or surgical procedure within 30 days prior to the procedure or planned to have the interventional or surgical procedure within 60 days after implant procedure (e.g., cardioversion, ablation, percutaneous coronary intervention, etc);
- Recent (within 90 days prior to procedure) stroke, transient ischemic attack, or myocardial infarction;
- Life expectancy is less than 1 year;
- Current participation in another investigational drug or device study.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Prince of Wales Hospital, Shatin, Hong Konglead
- Jenscare Scientificcollaborator
Study Sites (1)
Prince of Wales Hospital
Shatin, Hong Kong
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Central Study Contacts
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- TREATMENT
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Clinical Assistant Professor
Study Record Dates
First Submitted
March 31, 2026
First Posted
April 7, 2026
Study Start
March 12, 2026
Primary Completion (Estimated)
September 30, 2027
Study Completion (Estimated)
March 31, 2028
Last Updated
September 18, 2026
Record last verified: 2026-09