Defining Dosimetric Reference Levels in Computed Tomography Spectral Scanning
NR Spectral
1 other identifier
observational
9,600
1 country
1
Brief Summary
Spectral computed tomography or dual-energy CT imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT but, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet RLs are an important and effective tools for optimizing patient exposure to ionizing radiation. Several articles were published between 2012 and 2017 when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses. The main objective of the study is to define dosimetric reference levels for the most commonly performed spectral computed tomography examinations in France.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P75+ for all trials
Started Sep 2025
Shorter than P25 for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
September 1, 2025
CompletedFirst Submitted
Initial submission to the registry
September 10, 2025
CompletedFirst Posted
Study publicly available on registry
December 26, 2025
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 31, 2025
CompletedStudy Completion
Last participant's last visit for all outcomes
June 30, 2026
ExpectedDecember 26, 2025
November 1, 2025
4 months
September 10, 2025
December 12, 2025
Conditions
Keywords
Outcome Measures
Primary Outcomes (38)
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and retrospective gating. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and prospective gating. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. DLP
Dose length product (DLP) expressed in mGy.cm will be recorded
Periprocedural
Secondary Outcomes (183)
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition type
Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Number of acquisitions
Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. CTDIvol
Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. DLP
Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. BMI
Periprocedural
- +178 more secondary outcomes
Study Arms (1)
Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below
Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below: 1. Chest CT for pulmonary embolism 2. Chest CT for other indications 3. Coronary CT with contrast injection and retrospective gating 4. Coronary CT with contrast injection and prospective gating 5. Cranial CT with contrast injection 6. Supra-aortic trunk CT 7. Neck and ear,nose and throat sphere CT with contrast injection 8. Oncological abdomen-pelvis CT scan 9. Abdomen-pelvis CT scan to check for kidney stones 10. Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones 11. Oncological chest-abdomen-pelvis CT scan 12. Non-oncological chest-abdomen-pelvis CT scan 13. Oncological chest-abdomen CT scan 14. Non-oncological chest-abdomen CT scan 15. Lower limb angiography 16. Cervical spine CT scan 17. Thoracic spine CT scan 18. Lumbar spine CT scan 19. Pelvis CT scan, 20. Extremities CT scan
Interventions
Commonly performed spectral computed tomography examinations in France
Eligibility Criteria
All adult patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
You may qualify if:
- Adult male/female patient (≥ 18 years old)
- Body Mass Index (BMI) between 18 and 35 kg/m²
- Patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
You may not qualify if:
- \- Pregnant women
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Centre Hospitalier Universitaire de Saint Etiennecollaborator
- Hôpital Louis Mourier, 92700 Colombescollaborator
- Centre Hospitalier de Valenciennescollaborator
- Hopital Louis Pradelcollaborator
- Centre Léon Bérard, Lyoncollaborator
- University Hospital, Bordeauxcollaborator
- Centre Hospitalier Lyon Sudcollaborator
- Institut Curiecollaborator
- Amiens University Hospitalcollaborator
- Poitiers University Hospitalcollaborator
- Henri Mondor Hospital, Créteilcollaborator
- Saint Antoine University Hospitalcollaborator
- Nord Ardennes Intercommunal Hospitalcollaborator
- Centre Antoine Lacassagne, Nicecollaborator
- Hôpital Edouard Herriot (GH Centre), Lyoncollaborator
- University Hospital, Lillecollaborator
- Bichat Hospitalcollaborator
- Centre Hospitalier Universitaire de Nīmeslead
- Institut Paoli Calmettes, Marseillecollaborator
- Hôpital Necker-Enfants Maladescollaborator
- CHU Hôpital Lariboisière APHPcollaborator
- Saint-Louis Hospital, Paris, Francecollaborator
Study Sites (1)
Nîmes University Hospital
Nîmes, Gard, 30029, France
Related Publications (9)
Henzler T, Fink C, Schoenberg SO, Schoepf UJ. Dual-energy CT: radiation dose aspects. AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S16-25. doi: 10.2214/AJR.12.9210.
PMID: 23097163BACKGROUNDGhasemi Shayan R, Oladghaffari M, Sajjadian F, Fazel Ghaziyani M. Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiol Res Pract. 2020 Apr 20;2020:1403957. doi: 10.1155/2020/1403957. eCollection 2020.
PMID: 32373363BACKGROUNDGreffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023 Apr;104(4):167-177. doi: 10.1016/j.diii.2022.11.003. Epub 2022 Nov 19.
PMID: 36414506BACKGROUNDDabli D, Frandon J, Belaouni A, Akessoul P, Addala T, Berny L, Beregi JP, Greffier J. Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study. Diagn Interv Imaging. 2022 Jan;103(1):31-40. doi: 10.1016/j.diii.2021.08.004. Epub 2021 Oct 6.
PMID: 34625394BACKGROUNDSi-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol. 2023 Jul 1;58(7):459-471. doi: 10.1097/RLI.0000000000000965. Epub 2023 Feb 22.
PMID: 36822663BACKGROUNDWortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol. 2020 Feb;27(1):45-50. doi: 10.1007/s10140-019-01733-9. Epub 2019 Nov 1.
PMID: 31673838BACKGROUNDNoda Y, Kawai N, Kawamura T, Kobori A, Miyase R, Iwashima K, Kaga T, Miyoshi T, Hyodo F, Kato H, Matsuo M. Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction. Br J Radiol. 2022 Jun 1;95(1134):20211163. doi: 10.1259/bjr.20211163. Epub 2022 Mar 4.
PMID: 35230135BACKGROUNDEtard C, Bigand E, Salvat C, Vidal V, Beregi JP, Hornbeck A, Greffier J. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol. 2017 Oct;27(10):4281-4290. doi: 10.1007/s00330-017-4780-5. Epub 2017 Mar 13.
PMID: 28289939BACKGROUNDGreffier J, Ferretti G, Rousseau J, Andreani O, Alonso E, Rauch A, Gillet R, Le Roy J, Cabrol-Faivre L, Douane F, David A, Henry S, Jacques T, Stefanovic X, Decoux E, Lafay F, Pilleul F, Couzon F, Boutet C, Woerly B, Baur P, Sans N, Faruch M, Moussier-Lherm A, Tselikas L, Jacquier A, Bigand E, Pessis E, Teriitehau C, Magnier F, Cassagnes L, Haberlay M, Boutteau D, De Kerviler E, Majorel-Gouthain C, Defez D, Vuillod A, Rouviere O, Hennequin L, Fohlen A, Alwan R, Malakhia A, Aubry S, Dohan A, Eresue-Bony M, Gautier R, Dal R, Dabli D, Hebert T, Kovacs R, Hadid-Beurrier L, Bousson V, Potel M, Barbotteau Y, Michel C, Habib-Geryes B, Andre M, Arnaud T, Bestion N, Ernst O, Monfraix S, Brillet PY, Guiu B, Boussel L, Demonchy M, Beregi JP, Frandon J. National dose reference levels in computed tomography-guided interventional procedures-a proposal. Eur Radiol. 2020 Oct;30(10):5690-5701. doi: 10.1007/s00330-020-06903-9. Epub 2020 May 2.
PMID: 32361774BACKGROUND
Study Officials
- STUDY CHAIR
Joël GREFFIER
Nîmes University Hospital
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- RETROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
September 10, 2025
First Posted
December 26, 2025
Study Start
September 1, 2025
Primary Completion
December 31, 2025
Study Completion (Estimated)
June 30, 2026
Last Updated
December 26, 2025