NCT07305103

Brief Summary

Spectral computed tomography or dual-energy CT imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT but, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet RLs are an important and effective tools for optimizing patient exposure to ionizing radiation. Several articles were published between 2012 and 2017 when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses. The main objective of the study is to define dosimetric reference levels for the most commonly performed spectral computed tomography examinations in France.

Trial Health

75
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
9,600

participants targeted

Target at P75+ for all trials

Timeline
2mo left

Started Sep 2025

Shorter than P25 for all trials

Geographic Reach
1 country

1 active site

Status
active not recruiting

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Progress82%
Sep 2025Jun 2026

Study Start

First participant enrolled

September 1, 2025

Completed
9 days until next milestone

First Submitted

Initial submission to the registry

September 10, 2025

Completed
4 months until next milestone

First Posted

Study publicly available on registry

December 26, 2025

Completed
5 days until next milestone

Primary Completion

Last participant's last visit for primary outcome

December 31, 2025

Completed
6 months until next milestone

Study Completion

Last participant's last visit for all outcomes

June 30, 2026

Expected
Last Updated

December 26, 2025

Status Verified

November 1, 2025

Enrollment Period

4 months

First QC Date

September 10, 2025

Last Update Submit

December 12, 2025

Conditions

Keywords

Radiation doseReference levelsRadiologySpectral Computed Tomography Imaging

Outcome Measures

Primary Outcomes (38)

  • Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and retrospective gating. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and prospective gating. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. CTDIvol

    Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).

    Periprocedural

  • Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. DLP

    Dose length product (DLP) expressed in mGy.cm will be recorded

    Periprocedural

Secondary Outcomes (183)

  • Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition type

    Periprocedural

  • Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Number of acquisitions

    Periprocedural

  • Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. CTDIvol

    Periprocedural

  • Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. DLP

    Periprocedural

  • Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. BMI

    Periprocedural

  • +178 more secondary outcomes

Study Arms (1)

Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below

Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below: 1. Chest CT for pulmonary embolism 2. Chest CT for other indications 3. Coronary CT with contrast injection and retrospective gating 4. Coronary CT with contrast injection and prospective gating 5. Cranial CT with contrast injection 6. Supra-aortic trunk CT 7. Neck and ear,nose and throat sphere CT with contrast injection 8. Oncological abdomen-pelvis CT scan 9. Abdomen-pelvis CT scan to check for kidney stones 10. Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones 11. Oncological chest-abdomen-pelvis CT scan 12. Non-oncological chest-abdomen-pelvis CT scan 13. Oncological chest-abdomen CT scan 14. Non-oncological chest-abdomen CT scan 15. Lower limb angiography 16. Cervical spine CT scan 17. Thoracic spine CT scan 18. Lumbar spine CT scan 19. Pelvis CT scan, 20. Extremities CT scan

Radiation: Spectral ComputedTomography

Interventions

Commonly performed spectral computed tomography examinations in France

Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodNon-Probability Sample
Study Population

All adult patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.

You may qualify if:

  • Adult male/female patient (≥ 18 years old)
  • Body Mass Index (BMI) between 18 and 35 kg/m²
  • Patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.

You may not qualify if:

  • \- Pregnant women

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Nîmes University Hospital

Nîmes, Gard, 30029, France

Location

Related Publications (9)

  • Henzler T, Fink C, Schoenberg SO, Schoepf UJ. Dual-energy CT: radiation dose aspects. AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S16-25. doi: 10.2214/AJR.12.9210.

    PMID: 23097163BACKGROUND
  • Ghasemi Shayan R, Oladghaffari M, Sajjadian F, Fazel Ghaziyani M. Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiol Res Pract. 2020 Apr 20;2020:1403957. doi: 10.1155/2020/1403957. eCollection 2020.

    PMID: 32373363BACKGROUND
  • Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023 Apr;104(4):167-177. doi: 10.1016/j.diii.2022.11.003. Epub 2022 Nov 19.

    PMID: 36414506BACKGROUND
  • Dabli D, Frandon J, Belaouni A, Akessoul P, Addala T, Berny L, Beregi JP, Greffier J. Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study. Diagn Interv Imaging. 2022 Jan;103(1):31-40. doi: 10.1016/j.diii.2021.08.004. Epub 2021 Oct 6.

    PMID: 34625394BACKGROUND
  • Si-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol. 2023 Jul 1;58(7):459-471. doi: 10.1097/RLI.0000000000000965. Epub 2023 Feb 22.

    PMID: 36822663BACKGROUND
  • Wortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol. 2020 Feb;27(1):45-50. doi: 10.1007/s10140-019-01733-9. Epub 2019 Nov 1.

    PMID: 31673838BACKGROUND
  • Noda Y, Kawai N, Kawamura T, Kobori A, Miyase R, Iwashima K, Kaga T, Miyoshi T, Hyodo F, Kato H, Matsuo M. Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction. Br J Radiol. 2022 Jun 1;95(1134):20211163. doi: 10.1259/bjr.20211163. Epub 2022 Mar 4.

    PMID: 35230135BACKGROUND
  • Etard C, Bigand E, Salvat C, Vidal V, Beregi JP, Hornbeck A, Greffier J. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol. 2017 Oct;27(10):4281-4290. doi: 10.1007/s00330-017-4780-5. Epub 2017 Mar 13.

    PMID: 28289939BACKGROUND
  • Greffier J, Ferretti G, Rousseau J, Andreani O, Alonso E, Rauch A, Gillet R, Le Roy J, Cabrol-Faivre L, Douane F, David A, Henry S, Jacques T, Stefanovic X, Decoux E, Lafay F, Pilleul F, Couzon F, Boutet C, Woerly B, Baur P, Sans N, Faruch M, Moussier-Lherm A, Tselikas L, Jacquier A, Bigand E, Pessis E, Teriitehau C, Magnier F, Cassagnes L, Haberlay M, Boutteau D, De Kerviler E, Majorel-Gouthain C, Defez D, Vuillod A, Rouviere O, Hennequin L, Fohlen A, Alwan R, Malakhia A, Aubry S, Dohan A, Eresue-Bony M, Gautier R, Dal R, Dabli D, Hebert T, Kovacs R, Hadid-Beurrier L, Bousson V, Potel M, Barbotteau Y, Michel C, Habib-Geryes B, Andre M, Arnaud T, Bestion N, Ernst O, Monfraix S, Brillet PY, Guiu B, Boussel L, Demonchy M, Beregi JP, Frandon J. National dose reference levels in computed tomography-guided interventional procedures-a proposal. Eur Radiol. 2020 Oct;30(10):5690-5701. doi: 10.1007/s00330-020-06903-9. Epub 2020 May 2.

    PMID: 32361774BACKGROUND

Study Officials

  • Joël GREFFIER

    Nîmes University Hospital

    STUDY CHAIR

Study Design

Study Type
observational
Observational Model
COHORT
Time Perspective
RETROSPECTIVE
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

September 10, 2025

First Posted

December 26, 2025

Study Start

September 1, 2025

Primary Completion

December 31, 2025

Study Completion (Estimated)

June 30, 2026

Last Updated

December 26, 2025

Record last verified: 2025-11

Locations