Pilot Feasibility Study of a Novel Non-invasive Device for Diagnosis of Anemia
1 other identifier
observational
25
1 country
1
Brief Summary
In low-resource areas of the world, anemia screening relies on analyzing a blood sample and is generally carried out in health facilities. Current anemia screening approaches have not yielded satisfactory results due to critical limitations including lack of a) reliable access to laboratory facilities, b) reliable non-invasive out-of-hospital screening tools for community health-workers, c) integration of anemia data across health systems and d) distinction between hemolytic and nutritional causes. Currently available non-invasive tools have unacceptably low accuracy and cannot distinguish between nutritional and hemolytic etiologies. Prototype Anemia Diagnostic Assistant (ADA) We have developed a prototype Anemia Diagnostic Assistant for non-invasive, simultaneous detection of two markers of anemia, blood hemoglobin and the End-Tidal carbon monoxide levels. The device comprises an optical sensor module and ETCO breath sampling module. The unique and significant advantage of the instrument is its ability to detect, independently, two orthogonal variables that are required for differential diagnosis of the nutritional and hemolytic anemia:
- 1.Hemoglobin concentration using a non-invasive diffuse reflectance spectroscopy. Using high-fidelity, 11 wave-length spectral sensor, the device will provide optical quantification of hemoglobin levels. Optical hemoglobin sensing using diffused reflectance spectroscopy is well known, however; using traditional spectrophotometry instrumentation is very costly and thus impractical for this project. As a solution, we propose to use a validated commercially-available high accuracy 11-wavelength sensor within the visual and near-infrared (IR) range of the spectrum. The 11-wavelength spectrum will allow for sufficient accuracy in measuring the reflectance AND transmittance at isosbestic wavelengths on hemoglobin extinction curve as well as to compensate for the presence of melanin, which is a major interferant in optical determination of hemoglobin concentration. \[9\] The sensor was originally designed to collect data on the earlobe and/or the fingertip. Additional iterations include a sensor that straps around the wrist (similar to a smartwatch). Both versions of the device may be used in the study, and both feature standard USB or Bluetooth connectivity to ubiquitous mobile Android an iOS-based mobile platform .
- 2.End-tidal carbon monoxide. Using a non-invasive probe placed in proximity to the nostrils, the device will measure ETCO as a proxy measure of hemolysis. ETCO measurement as a measure for the presence of hemolysis is well documented in the medical literature and is commonly used in newborns units as a screening method for the presence of hemolysis \[7,8,10\]. A positive finding (presence of elevated levels of ETCO) will then prompt a referral for further hospital testing.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for all trials
Started Nov 2023
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
November 28, 2023
CompletedStudy Start
First participant enrolled
November 30, 2023
CompletedFirst Posted
Study publicly available on registry
December 6, 2023
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 12, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
December 12, 2023
CompletedJuly 24, 2024
July 1, 2024
12 days
November 28, 2023
July 23, 2024
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Difference in ADA hemoglobin values compared to serum hemoglobin values
Each participant will have their hemoglobin measured using the ADA and blood analysis. These values will then be compared to measure the difference between the ADA values and the serum values.
24 hours
Secondary Outcomes (1)
Incidence of hemolytic anemia
24 hours
Study Arms (1)
Healthy adults
Participants will be adults aged 18-70, male or female
Interventions
The Anemia Diagnostic Assistant is non-invasive and simultaneously detects two markers of anemia, blood hemoglobin and the End-Tidal carbon monoxide levels. The device comprises an optical sensor module and ETCO breath sampling module.
Venous blood will be drawn on the same day as the ADA was applied and sent to the hospital lab for hemoglobin analysis.
Eligibility Criteria
Participants will be recruited from the University of Utah campus. Potential participants can be students or staff.
You may qualify if:
- Healthy adult
You may not qualify if:
- Immunocompromised subjects
- Patients with known hemolytic disease, anemia, or other chronic illness
- Patients who do not provide consent.
- Those who are students or reporting staff of investigators will be excluded.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
University of Utah
Salt Lake City, Utah, 84112, United States
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Allison Judkins, MD
University of Utah
Study Design
- Study Type
- observational
- Observational Model
- COHORT
- Time Perspective
- PROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Principal Investigator
Study Record Dates
First Submitted
November 28, 2023
First Posted
December 6, 2023
Study Start
November 30, 2023
Primary Completion
December 12, 2023
Study Completion
December 12, 2023
Last Updated
July 24, 2024
Record last verified: 2024-07