Repeatability and Reproducibility of Lens Zonule Length Measurement Using ArcScan Insight 100
1 other identifier
observational
45
1 country
1
Brief Summary
The purpose of this study is to evaluate the intra-examiner repeatability and inter-examiner reproducibility in lens zonule length measurements using very high-frequency (VHF) digital ultrasound (ArcScan Insight 100).
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Aug 2022
Shorter than P25 for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
August 1, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
October 1, 2022
CompletedFirst Submitted
Initial submission to the registry
November 29, 2022
CompletedFirst Posted
Study publicly available on registry
December 20, 2022
CompletedStudy Completion
Last participant's last visit for all outcomes
December 31, 2022
CompletedDecember 20, 2022
December 1, 2022
2 months
November 29, 2022
December 12, 2022
Conditions
Outcome Measures
Primary Outcomes (2)
Repeatability of ArcScan Insight 100 zonule scans in normal eyes (standard deviation and coefficient of variation)
First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A. Operator B then performed the measurements using the same procedure and technique. The standard deviation and coefficient of variation of 3 repeated measurements for zonule length. will be calculated.
1 day
Reproducibility of ArcScan Insight 100 zonule scans in normal eyes
First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A. Operator B then performed the measurements using the same procedure and technique. The intraclass correlation is used to evaluate the difference between operator A and operator B.
1 day
Secondary Outcomes (1)
Repeatability of zonule length measurement with the built-in software (the intraclass correlation)
1 month
Study Arms (1)
Normal eyes
Interventions
The Insight-100 (ArcScan Inc., Golden, CO, USA) employs the high-frequency B-scan in the assessment of anterior segment parameters. Anormal saline coupling medium is formed with a disposable eyepiece between the 50 MHz transducer and the eye. The instrument moves the transducer in an arc so that the beam axis maintains approximate normality to the surface of the eye. The frequencies of cornea, anterior chamber, and lens are 60 MHz, 50 MHz and 50 MHz, respectively. The maximum arc scanning range is 70 degrees, and there is a linear scanning range of 29mm. The axial and lateral resolutions are 35 μm and 65 μm, respectively. It can measure structures behind the iris, including lens zonule.
Eligibility Criteria
Healthy subjects with no ocular disease except ametropia
You may qualify if:
- Subjects with no ocular disease except ametropia
- Subjects will be able to understand and willing to sign an informed consent
You may not qualify if:
- Previous ocular surgery
- Subjects not being able to tolerate or not willing to use pilocarpine eye drops
- Subjects has active ocular infection or inflammation
- Subjects not being able to look steadily
- Subjects not being able to open eyes wide in sterile saline even after topical anesthesia
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Eye Hospital of WMU
Hangzhou, Zhejiang, 325027, China
Related Publications (2)
Li X, Chang P, Li Z, Qian S, Zhu Z, Wang Q, Yun-E Z. Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography. Expert Rev Med Devices. 2020 Dec;17(12):1333-1340. doi: 10.1080/17434440.2020.1848541. Epub 2020 Dec 1.
PMID: 33196325BACKGROUNDZhu Z, Zou H, Li H, Wu X, Wang Y, Li Z, Zhao Y. Repeatability and reproducibility of anterior lens zonule length measurement using ArcScan insight 100 very high-frequency ultrasound. Expert Rev Med Devices. 2023 Jul-Dec;20(8):703-710. doi: 10.1080/17434440.2023.2223967. Epub 2023 Jun 13.
PMID: 37300312DERIVED
MeSH Terms
Conditions
Study Design
- Study Type
- observational
- Observational Model
- CASE ONLY
- Time Perspective
- CROSS SECTIONAL
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- Vice president
Study Record Dates
First Submitted
November 29, 2022
First Posted
December 20, 2022
Study Start
August 1, 2022
Primary Completion
October 1, 2022
Study Completion
December 31, 2022
Last Updated
December 20, 2022
Record last verified: 2022-12
Data Sharing
- IPD Sharing
- Will not share