NCT05657951

Brief Summary

The purpose of this study is to evaluate the intra-examiner repeatability and inter-examiner reproducibility in lens zonule length measurements using very high-frequency (VHF) digital ultrasound (ArcScan Insight 100).

Trial Health

43
At Risk

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Trial has exceeded expected completion date
Enrollment
45

participants targeted

Target at P25-P50 for all trials

Timeline
Completed

Started Aug 2022

Shorter than P25 for all trials

Geographic Reach
1 country

1 active site

Status
unknown

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

August 1, 2022

Completed
2 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

October 1, 2022

Completed
2 months until next milestone

First Submitted

Initial submission to the registry

November 29, 2022

Completed
21 days until next milestone

First Posted

Study publicly available on registry

December 20, 2022

Completed
11 days until next milestone

Study Completion

Last participant's last visit for all outcomes

December 31, 2022

Completed
Last Updated

December 20, 2022

Status Verified

December 1, 2022

Enrollment Period

2 months

First QC Date

November 29, 2022

Last Update Submit

December 12, 2022

Conditions

Outcome Measures

Primary Outcomes (2)

  • Repeatability of ArcScan Insight 100 zonule scans in normal eyes (standard deviation and coefficient of variation)

    First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A. Operator B then performed the measurements using the same procedure and technique. The standard deviation and coefficient of variation of 3 repeated measurements for zonule length. will be calculated.

    1 day

  • Reproducibility of ArcScan Insight 100 zonule scans in normal eyes

    First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A. Operator B then performed the measurements using the same procedure and technique. The intraclass correlation is used to evaluate the difference between operator A and operator B.

    1 day

Secondary Outcomes (1)

  • Repeatability of zonule length measurement with the built-in software (the intraclass correlation)

    1 month

Study Arms (1)

Normal eyes

Device: ArcScan Insight 100 very high-frequency digital ultrasound

Interventions

The Insight-100 (ArcScan Inc., Golden, CO, USA) employs the high-frequency B-scan in the assessment of anterior segment parameters. Anormal saline coupling medium is formed with a disposable eyepiece between the 50 MHz transducer and the eye. The instrument moves the transducer in an arc so that the beam axis maintains approximate normality to the surface of the eye. The frequencies of cornea, anterior chamber, and lens are 60 MHz, 50 MHz and 50 MHz, respectively. The maximum arc scanning range is 70 degrees, and there is a linear scanning range of 29mm. The axial and lateral resolutions are 35 μm and 65 μm, respectively. It can measure structures behind the iris, including lens zonule.

Normal eyes

Eligibility Criteria

Sexall
Healthy VolunteersYes
Age GroupsChild (0-17), Adult (18-64), Older Adult (65+)
Sampling MethodProbability Sample
Study Population

Healthy subjects with no ocular disease except ametropia

You may qualify if:

  • Subjects with no ocular disease except ametropia
  • Subjects will be able to understand and willing to sign an informed consent

You may not qualify if:

  • Previous ocular surgery
  • Subjects not being able to tolerate or not willing to use pilocarpine eye drops
  • Subjects has active ocular infection or inflammation
  • Subjects not being able to look steadily
  • Subjects not being able to open eyes wide in sterile saline even after topical anesthesia

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Eye Hospital of WMU

Hangzhou, Zhejiang, 325027, China

Location

Related Publications (2)

  • Li X, Chang P, Li Z, Qian S, Zhu Z, Wang Q, Yun-E Z. Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography. Expert Rev Med Devices. 2020 Dec;17(12):1333-1340. doi: 10.1080/17434440.2020.1848541. Epub 2020 Dec 1.

    PMID: 33196325BACKGROUND
  • Zhu Z, Zou H, Li H, Wu X, Wang Y, Li Z, Zhao Y. Repeatability and reproducibility of anterior lens zonule length measurement using ArcScan insight 100 very high-frequency ultrasound. Expert Rev Med Devices. 2023 Jul-Dec;20(8):703-710. doi: 10.1080/17434440.2023.2223967. Epub 2023 Jun 13.

MeSH Terms

Conditions

Cataract, zonular

Study Design

Study Type
observational
Observational Model
CASE ONLY
Time Perspective
CROSS SECTIONAL
Sponsor Type
OTHER
Responsible Party
PRINCIPAL INVESTIGATOR
PI Title
Vice president

Study Record Dates

First Submitted

November 29, 2022

First Posted

December 20, 2022

Study Start

August 1, 2022

Primary Completion

October 1, 2022

Study Completion

December 31, 2022

Last Updated

December 20, 2022

Record last verified: 2022-12

Data Sharing

IPD Sharing
Will not share