Intraoperative Fluid Management of Liposuction , Cardiometry Versus Rohrich Formula
1 other identifier
interventional
50
1 country
1
Brief Summary
The aim of the study is to compare the hemodynamic parameters of fluid resuscitation using Rohrich formula to cardiometry guided stroke volume variation in patients undergoing large volume liposuction surgery .
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for not_applicable
Started Jun 2022
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
May 20, 2022
CompletedFirst Posted
Study publicly available on registry
June 2, 2022
CompletedStudy Start
First participant enrolled
June 25, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
June 10, 2023
CompletedStudy Completion
Last participant's last visit for all outcomes
July 1, 2023
CompletedNovember 29, 2023
November 1, 2023
12 months
May 20, 2022
November 26, 2023
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Mean arterial blood pressure
Mean arterial blood pressure at 4 litre aspiration of fat and at every litre aspirated after.
1 year
Secondary Outcomes (2)
blood loss
1 year
urine output
1 year
Study Arms (2)
GROUP A
OTHERFluid administration in the form of lactated ringer will be managed by Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2(10). Rohrich formula represents fluid maintinance,deficit and replacement fluid ( 0.25 ml crystalloid given for each 1 ml above 4 litre of lipoaspirate).
GROUP B
OTHERPatients will receive fluid maintenance of lactated ringer 2 ml/kg/h, cardiometry guided SVV will be measured before and after induction then every 30 min ,it ranges between 5-15%, fluid bolus of lactated ringer 4 ml /kg over 15 min will be administered if SVV ˃ 15% .
Interventions
Electrical Cardiometry (EC) ICON (Osypka Medical, Berlin, Germany) is an FDA approved device used for non-invasive measurement of some hemodynamic parameters as cardiac output,cardiac index, stroke volume,stroke volume variation, systemic vascular resistance, thoracic fluid content, ICON (index of contractility), variation of ICON,corrected flow time and systolic time ratio.The set data of EC are the height, weight,hemoglobin, Oxygen saturation(SPO2),age, gender ,blood pressure and heart rate(HR) of the patient
Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2
Eligibility Criteria
You may qualify if:
- Male and female patients aged between 21 to 60 years.
- American Society of Anesthesiologists (ASA) Ӏ\& ӀӀ.
- Large volume liposuction.
You may not qualify if:
- Any bleeding\& coagulation disorders.
- Patients on regular anticoagulant or antiplatelet drugs.
- History of previous surgery in treated areas.
- Significant cardiopulmonary, hepatic or renal disease.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Ahmed Abdel Wahed Alilead
- Tanta Universitycollaborator
Study Sites (1)
Tanta University
Tanta, Gharbia Governorate, Egypt
Related Publications (3)
Rajput RS, Das S, Chauhan S, Bisoi A, Vasdev S. Comparison of cardiac output measurement by noninvasive method with electrical cardiometry and invasive method with thermodilution technique in patients undergoing coronary artery bypass grafting. World Journal of Cardiovascular Surgery. 2014;2014
BACKGROUNDRohrich RJ, Leedy JE, Swamy R, Brown SA, Coleman J. Fluid resuscitation in liposuction: a retrospective review of 89 consecutive patients. Plast Reconstr Surg. 2006 Feb;117(2):431-5. doi: 10.1097/01.prs.0000201477.30002.ce.
PMID: 16462322BACKGROUNDKadafi KT, Latief A, Pudjiadi AH. Determining pediatric fluid responsiveness by stroke volume variation analysis using ICON(R) electrical cardiometry and ultrasonic cardiac output monitor: A cross-sectional study. Int J Crit Illn Inj Sci. 2020 Jul-Sep;10(3):123-128. doi: 10.4103/IJCIIS.IJCIIS_87_18. Epub 2020 Sep 22.
PMID: 33409126BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Ahmed Abdel Wahed Ali, physician
Tanta University
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Purpose
- TREATMENT
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR INVESTIGATOR
- PI Title
- Principal Investigator
Study Record Dates
First Submitted
May 20, 2022
First Posted
June 2, 2022
Study Start
June 25, 2022
Primary Completion
June 10, 2023
Study Completion
July 1, 2023
Last Updated
November 29, 2023