Actual (reported)The objective of the investigation is to measure the humidity within a transfemoral amputee's prosthesis during physical activity in a pre-heated room, using both the vented AeroFit system and a non-vented comparator. The AeroFit System is a vented suspension system for transfemoral amputees, and it is combined with both a vented liner and a vented socket. Both the liner and the socket are designed to allow humidity to evaporate from the residual limb skin and out of the socket. The system is intended to reduce sweat build-up on the amputees' residual limb. At least ten transfemoral amputees will be fitted to the AeroFit socket and liner. After a minimum of 2 weeks of adaptation, subjects will have two humidity measurement sessions on two separate days, one day for the investigational device and one for the comparator. Each measurement session will take place during the same time of the day. During the humidity measurement sessions, humidity and temperature sensors will be placed directly on the subject's residual limb, and the subject will walk for 20 minutes at self-selected walking speed on a treadmill in a pre-heated room of 28 degrees Celsius. After 20 minutes of walking and 10 minutes of rest, the subject will perform the four square step test and walk stairs and humidity and temperature measurements will be collected throughout the whole time. After the stairs activity, the subject will be seated and will remove the socket, liner and sensors. The subject group will be randomized into two groups, A and B. Group A's first measurement session will be using the investigational device, Group B's first measurement session will be using the comparator. Amputees often deal with sweat inside their prostheses, which can affect their suspension and skin health. The Aerofit system is intended to assist with that problem. The investigation is the first step in collecting a pivotal dataset to confirm the sweat build-up inside amputees' prosthesis is reduced with a breathable suspension system.
Registry-reported information. Elapsed time and enrollment totals alone do not measure study progress or recruitment pace.
March 10, 2022
Actual (reported)Click on a node to explore related trials.
Some registry-reported names shown below are not yet linked in this graph.
Dates and qualifiers reported by the registry. Estimated dates do not confirm that a milestone has occurred.
October 22, 2021
Actual (reported)November 9, 2021
Actual (reported)March 10, 2022
Actual (reported)March 10, 2022
Actual (reported)March 15, 2022
Actual (reported)October 21, 2026
Actual (reported)Area Under the Relative Humidity-Time Curve Ratio (Residual Limb/Sound Limb)
Relative humidity (rH) and temperature data were acquired using an MSR147WD wireless data logger system with sensors (MSR Electronics GmbH, Seuzach, Switzerland). Relative humidity was measured within the prosthetic liner on the residual limb and on the sound limb during treadmill walking in a heated room. The area under the relative humidity-time curve (AUC) was calculated over the measurement period using the trapezoidal rule implemented in locally written MATLAB® code. For each subject and test condition, the residual limb AUC was normalized by dividing it by the corresponding sound limb AUC: Normalized AUC = Residual limb rH AUC ÷ Sound limb rH AUC. The reported outcome is this ratio. A value of 1 indicates that the rH over time on the residual limb was equal to the sound limb. Values greater than 1 indicate greater cumulative rH on the residual limb relative to the sound limb, whereas values less than 1 indicate lower cumulative rH. Lower values represent more favorable outcome.
measurement day 1 (either vented or non-vented system depending on which intervention group) vs measurement day 2 (either vented or non-vented system depending on which intervention group)
Perceived on Skin Humidity
measurement day 1 (either vented or non-vented system depending on which intervention group) vs measurement day 2 (either vented or non-vented system depending on which intervention group)
Perceived Prosthetic Stability (CLASS Stability Subscale Score)
measurement day 1 (either vented or non-vented system depending on which intervention group) vs measurement day 2 (either vented or non-vented system depending on which intervention group)
Perceived Prosthetic Suspension (CLASS Suspension Subscale Score)
measurement day 1 (either vented or non-vented system depending on which intervention group) vs measurement day 2 (either vented or non-vented system depending on which intervention group)
Perceived Prosthetic Comfort (CLASS Comfort Subscale Score)
measurement day 1 (either vented or non-vented system depending on which intervention group) vs measurement day 2 (either vented or non-vented system depending on which intervention group)
Subjects will be randomized in to two groups, A and B. Group A starts with humidity measurements on vented suspension system.
Subjects will be randomized in to two groups, A and B. Group B starts with humidity measurements on non-vented suspension system.
The AeroFit TF Liner is a vented silicone liner which allows for humid evaporation from the amputee's skin and through the liner. The AeroFit TF Socket is made in the same way as conventional Direct Socket, but in addition, perforations are drilled to the body of the socket and vents inserted into each perforation which allows for moisture evaporation from between liner and socket and out of socket. Overmolded textile on the outside of the vents covers the perforations to prevent dirt and dust to enter the socket.
SRT Prosthetics & Orthotics NPC - National Prosthetic Center
Indianapolis, Indiana, 46202, United States
Sashwati Roy, PhD
Indiana University
13 participants (actual enrollment reported by the registry).
First Submitted
November 9, 2021
First Posted
March 15, 2022
Study Start
October 22, 2021
Actual (reported)Össur HSM Seal-In Silicon liner (non-vented)
Registry-reported names are shown in full. Names without a link have not yet been matched to a Syfrah profile.
Contact the study team to confirm eligibility.
Primary Completion
March 10, 2022
Actual (reported)Study Completion
March 10, 2022
Actual (reported)Last Updated
October 21, 2026
Results First Posted
October 21, 2026
Record last verified: 2026-09
Download the complete ClinicalTrials.gov record imported by Syfrah, including fields not shown in this page. The registry may contain a newer revision.
Source: ClinicalTrials.gov.
JSON downloads include source attribution and retrieval details alongside the unchanged original record or the separately normalized values.
Source retrieved: