Comparison of Efficiency and Effectiveness of Two Types of Bonded Orthodontic Retainers: an RCT.
1 other identifier
interventional
114
1 country
1
Brief Summary
Comparson of efficiency and effectiveness of twisted/coaxial and linked retainers, placed under relative versus absolute isolation.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started Sep 2020
Typical duration for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
September 1, 2020
CompletedFirst Submitted
Initial submission to the registry
January 11, 2022
CompletedFirst Posted
Study publicly available on registry
February 22, 2022
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 1, 2022
CompletedStudy Completion
Last participant's last visit for all outcomes
September 1, 2023
CompletedDecember 13, 2023
December 1, 2023
2.2 years
January 11, 2022
December 12, 2023
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Little Irregularity index
Stability of treatment. The index measures the distance, in millimetres, between the contact points of crooked teeth, and then adds them together. Therefore,the Irregularity Index is the sum of all the displaced contacts between the anterior teeth (canine to canine)
Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)
Secondary Outcomes (5)
Failure of the retainer (1)
Through study completion (2 years)
Failure of the retainer (2)
Through study completion (2 years)
Periodontal index- periodontal status
Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)
Periodontal index- BoP
Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)
Periodontal index- plaque
Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)
Study Arms (2)
Bonding with rubberdam
EXPERIMENTALThe retainer is bonded under rubber dam isolation
Bonding under relative isolation
ACTIVE COMPARATORThe retainer is bonded under relative isolation (hygrophormic suction, cotton pads)
Interventions
twisted 0.0195 dead-soft coaxial wire (Respond; Ormco, Orange, Calif)
Ortho-flextech (Reliance orthodontic products, Itasca III, USA)
Eligibility Criteria
You may qualify if:
- Fixed orthodontic appliances upper and lower jaw
- Patient stays for 2 years in Belgium
- Parents consent
- Proper oral hygiene
You may not qualify if:
- Orthognathic surgery
- Craniofacial disorders
- Cleft lip palate patients
- Orthodontic treatment without fixed appliances
- Extra retention other than bonded wire in the lower jaw
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
University of Ghent
Ghent, 9000, Belgium
Related Publications (8)
Stormann I, Ehmer U. A prospective randomized study of different retainer types. J Orofac Orthop. 2002 Jan;63(1):42-50. doi: 10.1007/s00056-002-0040-6. English, German.
PMID: 11974451BACKGROUNDEngeler OG, Dalstra M, Arnold DT, Steineck M, Verna C. In vitro comparison of the torsional load transfer of various commercially available stainless-steel wires used for fixed retainers in orthodontics. J Orthod. 2021 Jun;48(2):118-126. doi: 10.1177/1465312520972402. Epub 2020 Nov 24.
PMID: 33231109BACKGROUNDFerreira LA, Sapata DM, Provenzano MGA, Hayacibara RM, Ramos AL. Periodontal parameters of two types of 3 x 3 orthodontic retainer: a longitudinal study. Dental Press J Orthod. 2019 Aug 1;24(3):64-70. doi: 10.1590/2177-6709.24.3.064-070.oar.
PMID: 31390451BACKGROUNDSifakakis I, Eliades T, Bourauel C. Residual stress analysis of fixed retainer wires after in vitro loading: can mastication-induced stresses produce an unfavorable effect? Biomed Tech (Berl). 2015 Dec;60(6):617-22. doi: 10.1515/bmt-2015-0013.
PMID: 26057215BACKGROUNDLiebenberg WH. Extending the use of rubber dam isolation: alternative procedures. Part II. Quintessence Int. 1993 Jan;24(1):7-17.
PMID: 8511260BACKGROUNDArnold DT, Dalstra M, Verna C. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics. J Orthod. 2016 Jun;43(2):121-9. doi: 10.1080/14653125.2016.1155814. Epub 2016 Apr 22.
PMID: 27104351BACKGROUNDArnone R. Bonding orthodontic lower 3 to 3 retainers with a rubber dam: a second generation step-by-step procedure. Am J Orthod Dentofacial Orthop. 1999 Oct;116(4):432-4. doi: 10.1016/s0889-5406(99)70229-5.
PMID: 10511672BACKGROUNDAldrees AM, Al-Mutairi TK, Hakami ZW, Al-Malki MM. Bonded orthodontic retainers: a comparison of initial bond strength of different wire-and-composite combinations. J Orofac Orthop. 2010 Jul;71(4):290-9. doi: 10.1007/s00056-010-9947-5. Epub 2010 Jul 30. English, German.
PMID: 20676816BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- STUDY CHAIR
Guy De Pauw, Prof
Head of orthodontics
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Purpose
- TREATMENT
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
January 11, 2022
First Posted
February 22, 2022
Study Start
September 1, 2020
Primary Completion
December 1, 2022
Study Completion
September 1, 2023
Last Updated
December 13, 2023
Record last verified: 2023-12
Data Sharing
- IPD Sharing
- Will not share