NCT05250765

Brief Summary

Comparson of efficiency and effectiveness of twisted/coaxial and linked retainers, placed under relative versus absolute isolation.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
114

participants targeted

Target at P50-P75 for not_applicable

Timeline
Completed

Started Sep 2020

Typical duration for not_applicable

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

September 1, 2020

Completed
1.4 years until next milestone

First Submitted

Initial submission to the registry

January 11, 2022

Completed
1 month until next milestone

First Posted

Study publicly available on registry

February 22, 2022

Completed
9 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

December 1, 2022

Completed
9 months until next milestone

Study Completion

Last participant's last visit for all outcomes

September 1, 2023

Completed
Last Updated

December 13, 2023

Status Verified

December 1, 2023

Enrollment Period

2.2 years

First QC Date

January 11, 2022

Last Update Submit

December 12, 2023

Conditions

Keywords

Orthodontic retainersIsolationBondingTwistflex retainerCoaxial retainerOrthoflexTech retainerFixed retainer

Outcome Measures

Primary Outcomes (1)

  • Little Irregularity index

    Stability of treatment. The index measures the distance, in millimetres, between the contact points of crooked teeth, and then adds them together. Therefore,the Irregularity Index is the sum of all the displaced contacts between the anterior teeth (canine to canine)

    Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)

Secondary Outcomes (5)

  • Failure of the retainer (1)

    Through study completion (2 years)

  • Failure of the retainer (2)

    Through study completion (2 years)

  • Periodontal index- periodontal status

    Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)

  • Periodontal index- BoP

    Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)

  • Periodontal index- plaque

    Measured before removing braces (T0), after 6 months (T1), 1 year (T2) and 2 years (T3)

Study Arms (2)

Bonding with rubberdam

EXPERIMENTAL

The retainer is bonded under rubber dam isolation

Device: Twistflex retainerDevice: Orthoflex retainer

Bonding under relative isolation

ACTIVE COMPARATOR

The retainer is bonded under relative isolation (hygrophormic suction, cotton pads)

Device: Twistflex retainerDevice: Orthoflex retainer

Interventions

twisted 0.0195 dead-soft coaxial wire (Respond; Ormco, Orange, Calif)

Bonding under relative isolationBonding with rubberdam

Ortho-flextech (Reliance orthodontic products, Itasca III, USA)

Bonding under relative isolationBonding with rubberdam

Eligibility Criteria

Sexall
Healthy VolunteersYes
Age GroupsChild (0-17), Adult (18-64), Older Adult (65+)

You may qualify if:

  • Fixed orthodontic appliances upper and lower jaw
  • Patient stays for 2 years in Belgium
  • Parents consent
  • Proper oral hygiene

You may not qualify if:

  • Orthognathic surgery
  • Craniofacial disorders
  • Cleft lip palate patients
  • Orthodontic treatment without fixed appliances
  • Extra retention other than bonded wire in the lower jaw

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

University of Ghent

Ghent, 9000, Belgium

Location

Related Publications (8)

  • Stormann I, Ehmer U. A prospective randomized study of different retainer types. J Orofac Orthop. 2002 Jan;63(1):42-50. doi: 10.1007/s00056-002-0040-6. English, German.

    PMID: 11974451BACKGROUND
  • Engeler OG, Dalstra M, Arnold DT, Steineck M, Verna C. In vitro comparison of the torsional load transfer of various commercially available stainless-steel wires used for fixed retainers in orthodontics. J Orthod. 2021 Jun;48(2):118-126. doi: 10.1177/1465312520972402. Epub 2020 Nov 24.

    PMID: 33231109BACKGROUND
  • Ferreira LA, Sapata DM, Provenzano MGA, Hayacibara RM, Ramos AL. Periodontal parameters of two types of 3 x 3 orthodontic retainer: a longitudinal study. Dental Press J Orthod. 2019 Aug 1;24(3):64-70. doi: 10.1590/2177-6709.24.3.064-070.oar.

    PMID: 31390451BACKGROUND
  • Sifakakis I, Eliades T, Bourauel C. Residual stress analysis of fixed retainer wires after in vitro loading: can mastication-induced stresses produce an unfavorable effect? Biomed Tech (Berl). 2015 Dec;60(6):617-22. doi: 10.1515/bmt-2015-0013.

    PMID: 26057215BACKGROUND
  • Liebenberg WH. Extending the use of rubber dam isolation: alternative procedures. Part II. Quintessence Int. 1993 Jan;24(1):7-17.

    PMID: 8511260BACKGROUND
  • Arnold DT, Dalstra M, Verna C. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics. J Orthod. 2016 Jun;43(2):121-9. doi: 10.1080/14653125.2016.1155814. Epub 2016 Apr 22.

    PMID: 27104351BACKGROUND
  • Arnone R. Bonding orthodontic lower 3 to 3 retainers with a rubber dam: a second generation step-by-step procedure. Am J Orthod Dentofacial Orthop. 1999 Oct;116(4):432-4. doi: 10.1016/s0889-5406(99)70229-5.

    PMID: 10511672BACKGROUND
  • Aldrees AM, Al-Mutairi TK, Hakami ZW, Al-Malki MM. Bonded orthodontic retainers: a comparison of initial bond strength of different wire-and-composite combinations. J Orofac Orthop. 2010 Jul;71(4):290-9. doi: 10.1007/s00056-010-9947-5. Epub 2010 Jul 30. English, German.

    PMID: 20676816BACKGROUND

MeSH Terms

Conditions

Recurrence

Condition Hierarchy (Ancestors)

Disease AttributesPathologic ProcessesPathological Conditions, Signs and Symptoms

Study Officials

  • Guy De Pauw, Prof

    Head of orthodontics

    STUDY CHAIR

Study Design

Study Type
interventional
Phase
not applicable
Allocation
RANDOMIZED
Masking
NONE
Purpose
TREATMENT
Intervention Model
PARALLEL
Model Details: 4 study groups are possible (2 types of retainers and 2 types of bonding protocol)
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

January 11, 2022

First Posted

February 22, 2022

Study Start

September 1, 2020

Primary Completion

December 1, 2022

Study Completion

September 1, 2023

Last Updated

December 13, 2023

Record last verified: 2023-12

Data Sharing

IPD Sharing
Will not share

Locations