Brief Summary
This study was conducted to investigate: The criterion related validity of Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement. The intra-rater reliability of Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P25-P50 for all trials
Started Jun 2021
Shorter than P25 for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
June 1, 2021
CompletedPrimary Completion
Last participant's last visit for primary outcome
September 1, 2021
CompletedStudy Completion
Last participant's last visit for all outcomes
September 25, 2021
CompletedFirst Submitted
Initial submission to the registry
October 3, 2021
CompletedFirst Posted
Study publicly available on registry
November 30, 2021
CompletedDecember 13, 2021
November 1, 2021
3 months
October 3, 2021
November 29, 2021
Conditions
Keywords
Outcome Measures
Primary Outcomes (2)
test Validation of rebee wearable sensor for measuring knee Range of motion
The criterion related validity andof Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement.
day 1
test intrarater reliability of rebee wearable sensor to measure active knee flexion and extension ROM
the procedures was repeated two times with one week interval between measurements. Researcher was recorded all the measurement.
day 1
Interventions
Rebee is a wearable motion sensor package of sensor with its own mobile application, which measures range of joint movement in different planes easily which the patient able to wear the sensor and move easily to measure ROM and record the measurement at the application software Digital goniometer Goniometry has been described as a tool to measure angle. It gives the physician a useful method to diagnose musculoskeletal function in terms of ROM, monitor the progress of an intervention, record the data for future follow-up, and meet statutory and legal requirements for impairment rating and disability determinations where applicable
Eligibility Criteria
The participants were recruited from Faculty, staff, and students of Pharos University, Alexandria, Egypt. Graduate Program in Physical Therapy after achieving the inclusion criteria .
You may qualify if:
- Forty normal participant's age ranged from 30 to 45.
- The participant from both sex.
- Participant Body mass index (BMI) from (19 to 25) normal weight (BMI= weight (kg) / \[height (m)\] 2)
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Cairo Universitylead
Study Sites (1)
Pharos university at alexandria
Alexandria, 21500, Egypt
Study Officials
- STUDY DIRECTOR
Wadida H Abd elkader, PhD
Professor.dr
Study Design
- Study Type
- observational
- Observational Model
- OTHER
- Time Perspective
- RETROSPECTIVE
- Sponsor Type
- OTHER
- Responsible Party
- PRINCIPAL INVESTIGATOR
- PI Title
- demonstrator of basic science faculty of physical therapy
Study Record Dates
First Submitted
October 3, 2021
First Posted
November 30, 2021
Study Start
June 1, 2021
Primary Completion
September 1, 2021
Study Completion
September 25, 2021
Last Updated
December 13, 2021
Record last verified: 2021-11