NCT04509362

Brief Summary

One of the available Hybrid closed loop system is MiniMed 670G (Medtronic Diabetes, Northridge, CA, USA), which is indicated for children above 7 years old, adolescents and adults with Type 1 Diabetes. Several studies have shown improved HbA1c, time in target range, and SG variability in children, adolescents and adults with Type 1 Diabetes, where participants were experienced with using CSII therapy, assuming that the success of HCL systems depend on prior use of pump therapy. A recent study, published by diabetes team from Sidra Medicine, Doha has showed that children and adolescents with Type 1 Diabetes on MDI therapy can successfully initiate the HCL system, using a concise structured 10-day protocol, achieving better outcomes than in previous studies, where participants had previous experience with diabetes related technology and longer initiation process. The AHCL system, Minimed 780G is CE-marked includes additional functionality aiming to provide further protections from highs. The user can choose the algorithm to target a glucose level of 100 or 120 mg/dL. Like for the MiniMed 670G HCL system, users can also choose the algorithm to temporarily target a glucose value of 150 mg/dL. In addition, the AHCL system has the ability to administer correction bolus automatically, targeting 120 mg/dL. The AHCL algorithm was evaluated with a model-based algorithm design platform incorporating a virtual patient simulator, where additional changes were made (lower target ranges and automated correction boluses ( )). A recent study including 12 patients with type 1 diabetes on AHCL system, has shown no episodes of hypoglycemia or diabetic ketoacidosis, while maintaining 99% time spent in closed loop and high time in ra1\]\\nge ( ). AHCL decreased Auto Mode exits and alerts, and improves glycaemia without compromising safety, despite multiple food and exercise challenges ( ). Sidra Medicine is the only center for childhood diabetes in Qatar. Around 80% of type 1 diabetes patients are using a device (insulin pump/glucose sensor) and around 45% are using sensor-augmented pump (SAP)/HCL systems.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
34

participants targeted

Target at P25-P50 for all trials

Timeline
Completed

Started Oct 2020

Shorter than P25 for all trials

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

First Submitted

Initial submission to the registry

August 1, 2020

Completed
11 days until next milestone

First Posted

Study publicly available on registry

August 12, 2020

Completed
2 months until next milestone

Study Start

First participant enrolled

October 1, 2020

Completed
8 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

May 31, 2021

Completed
3 months until next milestone

Study Completion

Last participant's last visit for all outcomes

September 1, 2021

Completed
Last Updated

September 28, 2021

Status Verified

September 1, 2021

Enrollment Period

8 months

First QC Date

August 1, 2020

Last Update Submit

September 26, 2021

Conditions

Keywords

Type 1 DiabetesAdvanced Hybrid Closed Loop SystemMinimed 780GInitiation Protocol

Outcome Measures

Primary Outcomes (2)

  • TIR (70-180 mg/dl)

    Change from baseline to the first 3 months

    3 months

  • TIR (70-180 mg/dl

    Change from baseline to the 12 months

    12 months

Secondary Outcomes (10)

  • HbA1c change

    3 months

  • HbA1c change

    12 months

  • Sensor glucose wear

    3 months

  • Sensor glucose wear

    12 months

  • Auto Mode Usage

    3 months

  • +5 more secondary outcomes

Interventions

Evaluation of the use of an 8-day structured protocol to initiate patients from MDI to the AHCL system, in achieving safe glycemic control

Also known as: Minimed 780G

Eligibility Criteria

Age7 Years - 18 Years
Sexall
Age GroupsChild (0-17), Adult (18-64)
Sampling MethodNon-Probability Sample
Study Population

Participants with Type 1 Diabetes, on multiple daily injections, using self-monitoring of blood glucose or continuous glucose monitoring, no prior pump experience.

You may qualify if:

  • Clinical diagnosis of type 1 diabetes \>1 year prior to consent date. Diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not required.
  • HbA1c \< 12.5%
  • Age 7-17 years at the initiation of the system
  • Multiple Daily Injections (Basal Bolus therapy) with Total daily insulin use of great than 8.0 units per day over a 1-week period
  • Willing and able (access to internet from home) to download information into the Medtronic CareLink software
  • Clinically able to start the AHCL system
  • History of 3 clinic visits in the last year

You may not qualify if:

  • DKA in the 6 months prior to screening visit
  • Pregnancy
  • Untreated diabetes retinopathy, or other causes that ,in the investigator's opinion, precludes the individual from participating in the trial.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Sidra Medicine

Doha, Qa, 26999, Qatar

Location

Related Publications (10)

  • Garg SK, Weinzimer SA, Tamborlane WV, Buckingham BA, Bode BW, Bailey TS, Brazg RL, Ilany J, Slover RH, Anderson SM, Bergenstal RM, Grosman B, Roy A, Cordero TL, Shin J, Lee SW, Kaufman FR. Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes. Diabetes Technol Ther. 2017 Mar;19(3):155-163. doi: 10.1089/dia.2016.0421. Epub 2017 Jan 30.

    PMID: 28134564BACKGROUND
  • Grosman B, Wu D, Miller D, Lintereur L, Roy A, Parikh N, Kaufman FR. Sensor-Augmented Pump-Based Customized Mathematical Model for Type 1 Diabetes. Diabetes Technol Ther. 2018 Mar;20(3):207-221. doi: 10.1089/dia.2017.0333.

    PMID: 29565722BACKGROUND
  • Paldus B, Lee MH, Jones HM, McAuley SA, Horsburgh JC, Roem KL, Ward GM, MacIsaac RJ, Cohen N, Colman PG, Jenkins AJ, O'Neal DN. Glucose Control Using a Standard Versus an Enhanced Hybrid Closed Loop System: A Randomized Crossover Study. Diabetes Technol Ther. 2019 Jan;21(1):56-58. doi: 10.1089/dia.2018.0279.

    PMID: 30620641BACKGROUND
  • Thabit H, Hovorka R. Coming of age: the artificial pancreas for type 1 diabetes. Diabetologia. 2016 Sep;59(9):1795-805. doi: 10.1007/s00125-016-4022-4. Epub 2016 Jun 30.

  • Biester T, Nir J, Remus K, Farfel A, Muller I, Biester S, Atlas E, Dovc K, Bratina N, Kordonouri O, Battelino T, Philip M, Danne T, Nimri R. DREAM5: An open-label, randomized, cross-over study to evaluate the safety and efficacy of day and night closed-loop control by comparing the MD-Logic automated insulin delivery system to sensor augmented pump therapy in patients with type 1 diabetes at home. Diabetes Obes Metab. 2019 Apr;21(4):822-828. doi: 10.1111/dom.13585. Epub 2018 Dec 21.

  • U.S. Food and Drug Administration (2019) FDA approves first automated insulin delivery device for type 1 diabetes. Available from www.fda.gov/news-events/press-announcements/fda-approves-first-automated-insulin-delivery-device-type-1-diabetes. Accessed 21 March 2019

    RESULT
  • Weaver KW, Hirsch IB. The Hybrid Closed-Loop System: Evolution and Practical Applications. Diabetes Technol Ther. 2018 Jun;20(S2):S216-S223. doi: 10.1089/dia.2018.0091. Epub 2018 Jun 6.

  • Trevitt S, Simpson S, Wood A. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development? J Diabetes Sci Technol. 2016 May 3;10(3):714-23. doi: 10.1177/1932296815617968. Print 2016 May.

  • Forlenza GP, Pinhas-Hamiel O, Liljenquist DR, Shulman DI, Bailey TS, Bode BW, Wood MA, Buckingham BA, Kaiserman KB, Shin J, Huang S, Lee SW, Kaufman FR. Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes. Diabetes Technol Ther. 2019 Jan;21(1):11-19. doi: 10.1089/dia.2018.0264. Epub 2018 Dec 26.

  • Petrovski G, Al Khalaf F, Campbell J, Fisher H, Umer F, Hussain K. 10-Day structured initiation protocol from multiple daily injection to hybrid closed-loop system in children and adolescents with type 1 diabetes. Acta Diabetol. 2020 Jun;57(6):681-687. doi: 10.1007/s00592-019-01472-w. Epub 2020 Jan 17.

MeSH Terms

Conditions

Diabetes Mellitus, Type 1

Condition Hierarchy (Ancestors)

Diabetes MellitusGlucose Metabolism DisordersMetabolic DiseasesNutritional and Metabolic DiseasesEndocrine System DiseasesAutoimmune DiseasesImmune System Diseases

Study Design

Study Type
observational
Observational Model
COHORT
Time Perspective
PROSPECTIVE
Sponsor Type
OTHER
Responsible Party
SPONSOR

Study Record Dates

First Submitted

August 1, 2020

First Posted

August 12, 2020

Study Start

October 1, 2020

Primary Completion

May 31, 2021

Study Completion

September 1, 2021

Last Updated

September 28, 2021

Record last verified: 2021-09

Locations