Determination of Best PEEP (Positive End-expiratory Pressure) in Anesthetized Infants in Terms of Prevention of Atelectasis
1 other identifier
interventional
89
1 country
1
Brief Summary
Purpose of research; to determine the appropriate positive end-expiratory pressure to minimize atelectasis during general anesthesia in infants. Study design : Application of one pressure of PEEP among 3, 6, or 9 cmH2O during mechanical positive ventilation for general anesthesia to randomly assigned infants over 6 months to 13 months of age . Immediately after the start of anesthesia (PEEP=0) and before the end of anesthesia, the score of atelectasis is measured by lung ultrasonography with the standardized method. The scores at PEEP3, PEEP6, and PEEP9 will be compared to identify the appropriate PEEP at which atelectasis is the least likely to occur during anesthesia. Medical Equipment : Ultrasonography with 6 - 13 MHz linear probe, Cardio-Q esophageal Doppler The number of target subjects: According to the results of previous studies, the lung ultrasound score by ultrasonography at the end of anesthesia was 28.5 (IQR 21.8-37) without any recruitment (PEEP 0 cmH2O) (IQR 6-21.3). When PEEP of 5 cmH2O was maintained, the lung ultrasound score is 12.5 (IQR 6-21.3), which is lower than PEEP 0. It is assumed that the score at PEEP3 is 20, the score at optimal PEEP is 10, and the standard deviation is 11. Bonferroni correction is required for statistical analysis. In comparison between the two groups, alpha is used as the Bonferroni corrected alpha level of 0.05 / 3 = 0.017. The significance level alpha is fixed at 0.017 and the number of samples considering the 10% dropout rate when the power (1-β) is 80% is required to be 30 for each group. Data analysis and statistical methods: Atelectasis score, cardiac index, peak inspiratory pressure, and dynamic compliance will be compared by t-test between groups(PEEP3 vs PEEP 6, PEEP 3 vs PEEP 9, PEEP 6 vs PEEP 9). P \< 0.017 is going to be considered statistically significant.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for not_applicable
Started May 2019
Shorter than P25 for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
May 9, 2019
CompletedFirst Submitted
Initial submission to the registry
May 15, 2019
CompletedFirst Posted
Study publicly available on registry
May 31, 2019
CompletedPrimary Completion
Last participant's last visit for primary outcome
March 13, 2020
CompletedStudy Completion
Last participant's last visit for all outcomes
March 13, 2020
CompletedMarch 31, 2020
March 1, 2020
10 months
May 15, 2019
March 30, 2020
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Lung atelectasis score after surgery
Before the end of anesthesia, the degree of atelectasis is measured by lung ultrasonography and scored according to the standardized method. Comparison of the scores at PEEP3, PEEP6, and PEEP9 to identify the appropriate PEEP at which atelectasis is the least likely to occur during anesthesia. Lung atelectasis score: The 6-13 MHz linear probe of the ultrasonic device is applied perpendicular to the patient's ribs and evaluated using a 2 dimensional classic view. Transthoracic pulmonary ultrasound imaging is performed in 12 areas. One thoracic region is divided into 6 zones (caudal anterior, caudal lateral, caudal posterior, cranial anterior, cranial lateral, and cranial posterior) by three longitudinal lines (parasternal, anterior, and posterior axilla) and two axial lines (just above the diaphragm, nipple line). The degree of atelectasis(0-72 points) is the sum of the consolidation score (0-36 points) and the B-line score (0-36 points) in 12 areas.
before the end of anesthesia
Secondary Outcomes (3)
Cardiac index
During surgery, the cardiac index is measured using a transesophageal doppler for 5 minutes each before and after application of PEEP (3, 6, 9 cm H 2 O) according to the randomized, defined group of patients.
Peak inspiratory pressure
During surgery, the cardiac index is measured using a transesophageal doppler for 5 minutes each before and after application of PEEP (3, 6, 9 cm H 2 O) according to the randomized, defined group of patients.
Dynamic compliance
During surgery, the cardiac index is measured using a transesophageal doppler for 5 minutes each before and after application of PEEP (3, 6, 9 cm H 2 O) according to the randomized, defined group of patients.
Study Arms (3)
PEEP3
ACTIVE COMPARATORThe baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (3 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
PEEP6
ACTIVE COMPARATORThe baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (6 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
PEEP9
ACTIVE COMPARATORThe baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (9 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
Interventions
The baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (3 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
The baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (6 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
The baseline atelectasis score is measured using sonography with no PEEP. And then, the baseline cardiac index is measured using transesophageal doppler for 5 minutes each with 3 cmH2O of PEEP. Apply PEEP (9 cmH2O) according to the patient's randomized group, and maintain the PEEP until the end of the operation.
Eligibility Criteria
You may qualify if:
- \. American Society of Anesthesiologists (ASA PS) I-II
- \. pediatric general surgery or pediatric urology surgery under general anesthesia
- \. over 6 months of age and less than 13 months of age
- \. height and weight are 5-95% of peers
You may not qualify if:
- \. Congenital heart or lung disease
- \. hemodynamic unstable vital sign
- \. bronchopulmonary dysplasia
- \. laparoscopic surgery
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institue, Yonsei Universiy College of Medicine
Seoul, 120-752, South Korea
Related Publications (1)
Park S, Lee JH, Kim HJ, Choi H, Lee JR. Optimal positive end-expiratory pressure to prevent anaesthesia-induced atelectasis in infants: A prospective, randomised, double-blind trial. Eur J Anaesthesiol. 2021 Oct 1;38(10):1019-1025. doi: 10.1097/EJA.0000000000001483.
PMID: 33720065DERIVED
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- NONE
- Masking Details
- The physician who directly anesthetize the patient should not be aware of the patient's placement due to the nature of the study design and maintenance of anesthesia. The ultrasound examination of the patient's degree of atelectasis and data collection of cardiac index data was limited to a single anesthesiologist without knowing which group the patient is in. Blind cancellation is performed after data analysis is completed.
- Purpose
- PREVENTION
- Intervention Model
- PARALLEL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
May 15, 2019
First Posted
May 31, 2019
Study Start
May 9, 2019
Primary Completion
March 13, 2020
Study Completion
March 13, 2020
Last Updated
March 31, 2020
Record last verified: 2020-03
Data Sharing
- IPD Sharing
- Will not share