Subject´s Preference Regarding Hearing Performance and Functionality Using a New Sound Processor
1 other identifier
interventional
11
1 country
1
Brief Summary
The aim of this clinical investigation is to investigate the subject´s overall preference, hearing performance and self-reported assessments with the Investigational device and its precursor Sound Processor (Comparator) after 6 weeks in subjects with conductive/mixed hearing loss or Single Sided Deafness, (SSD).
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Feb 2019
Shorter than P25 for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
February 8, 2019
CompletedStudy Start
First participant enrolled
February 19, 2019
CompletedFirst Posted
Study publicly available on registry
February 21, 2019
CompletedPrimary Completion
Last participant's last visit for primary outcome
April 23, 2019
CompletedStudy Completion
Last participant's last visit for all outcomes
April 23, 2019
CompletedResults Posted
Study results publicly available
February 5, 2020
CompletedOctober 14, 2021
January 1, 2020
2 months
February 8, 2019
December 16, 2019
October 13, 2021
Conditions
Outcome Measures
Primary Outcomes (14)
Abbreviated Profile of Hearing Aid Benefit (APHAB)
Measuring of subscales Ease of communication, Reverberation, Background noise, Aversiveness and a Global score with the precursor sound processor at Day 0 and with the Investigational device after 6 weeks with a questionnaire. All subscales range from 0-100%, total score is the average of all subscales 0-100%, where 0% indicates no problems and 100% indicates always problem. A decrease in the APHAB values indicates an improvement. The change from visit 1 with the precursor sound processor to visit 3 with the Investigational device is presented. A positive value indicates an improvement with the Investigational device, a negative value an impairment.
Day 0 (Visit 1) and after 6 weeks (Visit 3)
Speech, Spatial, and Qualities of Hearing Scale (SSQ)
Measuring speech, spatial and hearing experiences with the precursor sound processor at Day 0 (Visit 1) and with Investigational device after 6 weeks (Visit 3) with a questionnaire. The Total score summarizes the parameters speech, spatial and hearing. A scale from 0 to 10, where 0 represents "can not hear at all", and 10 "hear perfectly" is used. An increase of a SSQ value reflects an improvement. The change from visit 1 with the precursor sound processor to visit 3 with the Investigational device is presented. A positive value indicates an improvement and a negative value an impairment.
Day 0 and after 6 weeks
Self-reported Assessment Regarding Satisfaction and Usability (QUEST Version 2)
Measuring QUEST (Self-reported assessment regarding satisfaction and usability) using a questionnaire, with the precursor sound processor at Day 0 (Visit 1) and with the Investigational device after 6 weeks (Visit 3). The QUEST form displays the scoring of 8 satisfaction items. The satisfaction items related to the characteristics of the device are: 1) dimensions, 2) weight, 3) adjustments, 4) safety, 5) durability, 6) simplicity of use, 7) comfort and 8) effectiveness. A scale from 1 to 5, where 1 represent not satisfied at all, 2 not very satisfied, 3 more or less satisfied, 4 quiet satisfied and 5 represents very satisfied. The three most important items of 1) dimensions, 2) weight, 3) adjustments, 4) safety, 5) durability, 6) simplicity of use, 7) comfort and 8) effectiveness were listed by each participant.
Day 0 and after 6 weeks
Audiometric Thresholds in Freefield, Pure Tone Average 4 (PTA4)
To measure threshold audiometry PTA4 (mean of 500, 1000, 2000 and 4000 Hz) with both the precursor sound processor and the Investigational device. The units reported for PTA4 are decibels (dB). The change from visit 1 with the precursor sound processor to visit 3 with the Investigational device is presented. As such, a lower or more negative score is more desirable and reflects a better ability to hear softer sounds.
Baseline at visit 1, 6 weeks after study start at visit 3
Audiometric Thresholds in Freefield, Individual Frequencies
To measure threshold audiometry at individual frequencies 250, 500, 1000, 2000, 3000, 4000, 6000 Hz with both the precursor sound processor and the Investigational device. The units reported for threshold audiometry are decibels (dB). The change from visit 1 with the precursor sound processor to visit 3 with the Investigational device is presented. As such, a lower or more negative score is more desirable and reflects a better ability to hear softer sounds.
6 weeks after study start
Adaptive Speech Recognition in Noise Ratio
To measure Adaptive speech recognition in noise with the precursor sound processor and the Investigational device. Measured as signal to noise ratio The adaptive speech test in noise was conducted using validated lists of phonetically balanced sentences, with speech and noise presented from the front (0 degrees azimuth). The speech is kept constant at 65 dB Sound Pressure Level (SPL) and the noise is adapted in dB steps to establish the speech-to-noise ratio (SNR) providing a 50% level of understanding. A ratio of 1 reflects the ability to correctly hear sentences at 65 dB, in the presence of 65 dB background noise. A lower ratio than 1 reflects the ability to correctly hear sentences below 65 dB. A ratio higher than 1 reflects the ability to correctly hear sentences presented above 65 dB. A lower or more negative score is more desirable and represent a better hearing in a noisy environment.
Baseline at visit 1, 6 weeks after study start at visit 3
Speech in Quiet
To measure Speech in quiet at 50, 65 and 80 dB with the precursor sound processor and the Investigational device. Speech in Quiet presents a list of words in a quiet environment at three different presentations levels, 50, 65 and 80 dB (decibel). The number of correct words perceived at each presentation level are counted and the percentage in relation to the total presented amount of words is calculated. A higher score reflects a higher percentage of correct words perceived, i.e. better hearing in a quiet environment.
Baseline at visit 1, 6 weeks after study start at visit 3
To Compare the Subject´s Overall Preference Regarding the Investigational Device and the Precursor Sound Processor
The test subject will be asked a question regarding preferred choice made by selection between Investigational device and the precursor sound processor (comparator). Three boxes can be ticked; Precursor Sound Processor, Investigational Device, No preference.
6 weeks after study start
To Assess the Subject's Experience Regarding Comfort
Measure Comfort by a visual analogue scale (VAS) 100 mm at Day 0 regarding the precursor sound processor and after 6 weeks regarding the Investigational device. Subject will be asked to put a line where they find most appropriate where 0 mm represents Not comfortable at all and 100 represents Most comfortable imaginable. The distance will be measured with a ruler and presented as a value between 0 and 100. A higher score reflects higher comfort.
Baseline at visit 1, 6 weeks after study start at visit 3
To Assess the Subject's Experience Regarding Usage; Magnet Choice
Magnet choice will be entered; four boxes are available, 1, 2, 3 and 4, the box with the strength chosen by the patient will be ticked. Magnet strength 1 is the weakest and 4 is the strongest.
6 weeks after study start
To Assess the Subject's Experience Regarding Usage; Battery Life Time
The patient will be asked a question regarding battery life; "How often was the battery changed". A free text field is available for answer.
6 weeks after study start
To Assess the Subject's Experience Regarding Usage; Softwear Pad
The patient will be asked a question "Did you use a SoftWear Pad in the last 6 weeks". The patient can tick a "Yes" or "No" box.
6 weeks after study start
To Assess the Subject's Experience Regarding Usage; Safety Line
The patient will be asked a question "Did you use a safety line in the last 6 weeks". The patient can tick a "Yes" or "No" box.
6 weeks after study start
To Assess the Subject's Experience Regarding Usage; Wireless Accessories
The patient will be asked a question "Did you use a Wireless accessory during the last 6 weeks". The patient can tick a "Yes" or "No" box.
6 weeks after study start
Study Arms (1)
Investigational device - Sound Processor
EXPERIMENTALInterventions
At visit 1 the subjects will complete self-reported assessments with respect to "pre-study experience" using precursor Sound Processor (comparator). At visit 1 the subjects will then receive the Investigational device (Sound Processor) which should be used during the following 6 weeks. At visit 3 the subjects will complete self-reported assessments regarding Investigational device and participate in audiology tests regarding both Sound Processors, comparator and Investigational device. The subject shall decide their preferred choice made by selection between Investigational device and the comparator.
Eligibility Criteria
You may qualify if:
- Completed clinical investigation CBAS5539, and an active user of the Osia System.
- Signed Informed consent.
- Subject with conductive or mixed hearing loss in the implanted ear. Bone conduction thresholds with pure tone average (PTA4; mean of 0.5, 1, 2 and 4 kHz) of ≤ 55 dB HL.
- OR subject with single-sided sensorineural deafness. Air conduction thresholds with a pure tone average PTA4 of ≤ 20 dB (decibel) HL (Hearing Level) (mean of 0.5, 1, 2 and 3 kHz) in the good ear.
You may not qualify if:
- Any ongoing soft tissue complication that could significantly affect the use of the Osia 2 Sound Processor during the 6 weeks period
- Use of ototoxic drugs that could be harmful to the hearing, as judged by the investigator
- Unable to follow investigational procedures and instructions, e.g. inability to complete quality of life scales or audiological testing as described in the Clinical Investigation Plan (CIP).
- Participation in another clinical investigation with pharmaceutical and/or device.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Cochlearlead
Study Sites (1)
HEARing CRC550 Swanston Street, Carlton
Melbourne, Victoria, 3053, Australia
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Results Point of Contact
- Title
- Professor Robert Cowan
- Organization
- Hearing CRC Melbourne
Study Officials
- PRINCIPAL INVESTIGATOR
Robert Cowan, Prof
HEARing CRC550, Carlton, Melbourne
Publication Agreements
- PI is Sponsor Employee
- No
- Restriction Type
- OTHER
- Restrictive Agreement
- Yes
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NA
- Masking
- NONE
- Purpose
- TREATMENT
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
February 8, 2019
First Posted
February 21, 2019
Study Start
February 19, 2019
Primary Completion
April 23, 2019
Study Completion
April 23, 2019
Last Updated
October 14, 2021
Results First Posted
February 5, 2020
Record last verified: 2020-01
Data Sharing
- IPD Sharing
- Will not share