Pilot Clinical Evaluation of the RHEA Vital Sign Vigilance System in Hospital Patients Patients
1 other identifier
interventional
15
1 country
1
Brief Summary
This study comparing both of the investigational device and reference device to gold standard Patient Monitor of the accuracy of heart rate and respiratory rate monitoring. The primary variables for the analysis of heart rate (HR) and respiratory rate (RR) are each the overall mean root mean square difference (RMSD). Results of the investigational device and reference device compared with the patient monitor are evaluated to see if there are equivalent. Motion and bed exit accuracy will be evaluated by comparing with the manual observation.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for not_applicable
Started Sep 2017
Shorter than P25 for not_applicable
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
August 30, 2017
CompletedFirst Posted
Study publicly available on registry
September 1, 2017
CompletedStudy Start
First participant enrolled
September 1, 2017
CompletedPrimary Completion
Last participant's last visit for primary outcome
November 24, 2017
CompletedStudy Completion
Last participant's last visit for all outcomes
November 24, 2017
CompletedApril 16, 2019
April 1, 2019
3 months
August 30, 2017
April 12, 2019
Conditions
Keywords
Outcome Measures
Primary Outcomes (2)
RMSD of Investigational Device's Heart Rate and Gold Standard Device's heart rate
Record 20 valid pair heart rate displayed in the investigational device and patient monitor at the same time every one minutes.Calculate the root mean square difference(RMSD) of the heart rate for the investigational device.
30 days
RMSD of Investigational Device's Respiratory Rate and Gold Standard Device's Respiratory rate
Record 20 valid pair respiratory rate displayed in the investigational device and patient monitor at the same time every one minutes.Calculate the root mean square difference(RMSD) of the respiratory rate for the investigational device.
30 days
Secondary Outcomes (4)
Heart Rate t Test Comparison result between the Investigational Device and the Reference Device
30 days
Respiratory Rate t Test Comparison result between the Investigational Device and the Reference Device
30 days
Motion Notification Accuracy(%)
30 days
Bed Exit Notification Accuracy(%)
30 days
Study Arms (2)
Investigational Group
EXPERIMENTALThe RHEA device and Patient Monitor Device are used to monitor the heart rate (HR) and respiratory rate (RR) of participants.
Reference Group
ACTIVE COMPARATORThe reference device and Patient Monitor Device are used to monitor the heart rate (HR) and respiratory rate (RR) of participants.
Interventions
The RHEA device and Philips Patient Monitor MX400 are used to monitor the heart rate (HR) and respiratory rate (RR) of participants.
The reference device Earlysense 2.0 system(vital sign monitoring system) and Philips Patient Monitor MX400 are used to monitor the heart rate (HR) and respiratory rate (RR) of participants.
Eligibility Criteria
You may qualify if:
- Male or female, 18 years old and above.
- Provide written informed consent.
- Weight ranging from 20 to 150 kg inclusive.
- Are located in a non-ICU hospital setting.
- Agree to not eat during the testing period.
- Agree to keep still.
You may not qualify if:
- Are connected to a device which may interfere with the device monitoring in this study.
- Are receiving any bedside care which may be incompatible with the study procedures.
- Sleep apnea.
- Pregnant or breastfeeding.
- A likely need to receive or undergo a procedure during the testing period.
- Cannot accept a nasal cannula, or have a monitor lead placed on the chest.
- A significant medical condition in the judgement of the investigator, which may compromise the study testing procedures.
- Are wearing pacemaker or defibrillator.
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Darma Inc.lead
- Medstar Health Research Institutecollaborator
Study Sites (1)
MedStar Health Research Institute, Inc.
Washington D.C., District of Columbia, 20770, United States
Study Officials
- PRINCIPAL INVESTIGATOR
Arrel Olano, MD
Medstar Health Research Institute
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- NON RANDOMIZED
- Masking
- NONE
- Purpose
- SCREENING
- Intervention Model
- CROSSOVER
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
August 30, 2017
First Posted
September 1, 2017
Study Start
September 1, 2017
Primary Completion
November 24, 2017
Study Completion
November 24, 2017
Last Updated
April 16, 2019
Record last verified: 2019-04
Data Sharing
- IPD Sharing
- Will not share