Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension
2 other identifiers
interventional
178
1 country
2
Brief Summary
This is an open-label, non-randomized trial that will be conducted at two clinical sites, Thomas Jefferson University (TJU) and the Hospital of the University of Pennsylvania (HUP). Enrolled patients undergoing trans-jugular liver biopsy with hepatic vein pressure gradient (HVPG) measurements will receive a continuous infusion of Sonazoid® (GE Healthcare, Oslo, Norway) co-infused with 0.9% NaCl solution over a 5-10 minute time period. Ultrasound imaging will be performed using a Logiq 9 scanner with a 4C transducer (GE Healthcare, Milwaukee, WI) and the novel SHAPE (subharmonic aided pressure estimation) algorithm will be used to measure pressure values in the hepatic and portal veins. Data will be stored on a PC and compared to pressure-catheter measurements, Subjects identified in the initial examination as having portal hypertension (by HVPG results) will be monitored by SHAPE for up to 18 months. These subjects typically have surveillance Computed tomography (CT) or magnetic resonance imaging (MRI) scans every 6 months to screen for liver cancer, and at those times a repeat SHAPE examination will be performed (ideally within 1 month of their clinically indicated imaging follow up appointment). In patients who undergo more frequent screening (generally 3 month intervals), SHAPE exams will be performed at 6 month intervals. Any repeat trans-jugular liver biopsies performed in this population will also trigger a repeat SHAPE study. Results of blood test evaluations (performed every 3 months in this population), medication, concomitant imaging study or procedure (including endoscopies) will be noted (all blood tests and imaging are clinically indicated only and are not required by this protocol). The end point for this part of the study will be any one new complication (e.g., liver cancer) or a marked worsening in any complication, liver transplantation, death, or the end of this clinical trial (after 3 years). The investigators expect these patients will be monitored three times during the course of this clinical trial. The time to reach the end point will be noted if a new complication or a marked worsening in any complication occurs.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for phase_4
Started Apr 2015
Longer than P75 for phase_4
2 active sites
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
April 6, 2015
CompletedFirst Submitted
Initial submission to the registry
May 14, 2015
CompletedFirst Posted
Study publicly available on registry
July 2, 2015
CompletedPrimary Completion
Last participant's last visit for primary outcome
March 31, 2019
CompletedStudy Completion
Last participant's last visit for all outcomes
March 31, 2019
CompletedResults Posted
Study results publicly available
August 13, 2021
CompletedAugust 13, 2021
July 1, 2021
4 years
May 14, 2015
April 20, 2021
July 20, 2021
Conditions
Outcome Measures
Primary Outcomes (3)
Diagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standard
Evaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).
up to 1 day
SHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)
Evaluate the correlation between in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg) in patients undergoing a transjugular liver biopsy.
up to 1 day
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients
Determine if SHAPE measurements (in dB) can provide a quantitative, noninvasive measurement of hepatic venous pressure gradient (HVPG) to monitor disease progression or treatment response in patients identified with portal hypertension by comparing the results to repeat biopsies and/or clinical outcomes.
up to 2 hours
Study Arms (1)
SHAPE measurement
EXPERIMENTAL48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Interventions
Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Eligibility Criteria
You may qualify if:
- Be scheduled for trans-jugular liver biopsy the day of the ultrasound procedure.
- Be at least 21 years of age.
- Be medically stable.
- If a female of child-bearing potential, must have a negative pregnancy test.
- Be conscious and able to comply with study procedures.
- Have read and signed the IRB-approved Informed Consent form for participating in the study.
You may not qualify if:
- Females who are pregnant or nursing.
- Patients not scheduled for trans-jugular liver biopsy
- Patients who have received an investigational drug in the 30 days before study drug administration, or will receive one within 72 h afterwards,.
- Patients with known or suspected right-to-left, bi-directional, or transient right-to-left cardiac shunts
- Patients with pulmonary hypertension or unstable cardiopulmonary conditions
- Patients currently on chemotherapy or with other primary cancers requiring systemic or hepatic loco-regional treatment.
- Patients who are medically unstable, patients who are seriously or terminally ill, and patients whose clinical course is unpredictable. For example:
- Patients on life support or in a critical care unit.
- Patients with unstable occlusive disease (e.g., crescendo angina)
- Patients with clinically unstable cardiac arrhythmias, such as recurrent ventricular tachycardia.
- Patients with uncontrolled congestive heart failure (NYHA Class IV)
- Patients with recent cerebral hemorrhage.
- Patients who have undergone surgery within 24 hours prior to the study sonographic examination.
- Patients with a history of anaphylactic allergy to eggs or egg products, manifested by one or more of the following symptoms: generalized urticaria, difficulty in breathing, swelling of the mouth and throat, hypotension, or shock. (Subjects with nonanaphylactic allergies to eggs or egg products may be enrolled in the study, but must be watched carefully for 1 h following the administration of SONAZOID).
- Patients with congenital heart defects.
- +3 more criteria
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (2)
University of Pennsylvania
Philadelphia, Pennsylvania, 19104, United States
Thomas Jefferson University, Dept of Radiology
Philadelphia, Pennsylvania, 19107, United States
Related Publications (2)
Eisenbrey JR, Dave JK, Halldorsdottir VG, Merton DA, Miller C, Gonzalez JM, Machado P, Park S, Dianis S, Chalek CL, Kim CE, Baliff JP, Thomenius KE, Brown DB, Navarro V, Forsberg F. Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient. Radiology. 2013 Aug;268(2):581-8. doi: 10.1148/radiol.13121769. Epub 2013 Mar 22.
PMID: 23525208BACKGROUNDGupta I, Eisenbrey JR, Machado P, Stanczak M, Wessner CE, Shaw CM, Gummadi S, Fenkel JM, Tan A, Miller C, Parent J, Schultz S, Soulen MC, Sehgal CM, Wallace K, Forsberg F. Diagnosing Portal Hypertension with Noninvasive Subharmonic Pressure Estimates from a US Contrast Agent. Radiology. 2021 Jan;298(1):104-111. doi: 10.1148/radiol.2020202677. Epub 2020 Nov 17.
PMID: 33201789DERIVED
MeSH Terms
Conditions
Interventions
Condition Hierarchy (Ancestors)
Results Point of Contact
- Title
- Flemming Forsberg, PhD
- Organization
- Thomas Jefferson University
Study Officials
- PRINCIPAL INVESTIGATOR
Flemming Forsberg, PhD
Thomas Jefferson University
Publication Agreements
- PI is Sponsor Employee
- No
- Restrictive Agreement
- No
Study Design
- Study Type
- interventional
- Phase
- phase 4
- Allocation
- NA
- Masking
- NONE
- Purpose
- DIAGNOSTIC
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
May 14, 2015
First Posted
July 2, 2015
Study Start
April 6, 2015
Primary Completion
March 31, 2019
Study Completion
March 31, 2019
Last Updated
August 13, 2021
Results First Posted
August 13, 2021
Record last verified: 2021-07