Clinical Investigation of AcrySof® IQ ReSTOR® +2.5 D Multifocal Intraocular Lens (IOL) Model SN6AD2 [SV25T0]
1 other identifier
interventional
409
0 countries
N/A
Brief Summary
The purpose of this study is to compare the safety and efficacy of an investigational multifocal intraocular lens (IOL) to an FDA-approved monofocal IOL.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P75+ for not_applicable
Started Feb 2012
Shorter than P25 for not_applicable
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
First Submitted
Initial submission to the registry
January 12, 2012
CompletedFirst Posted
Study publicly available on registry
January 16, 2012
CompletedStudy Start
First participant enrolled
February 1, 2012
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 1, 2012
CompletedStudy Completion
Last participant's last visit for all outcomes
December 1, 2012
CompletedResults Posted
Study results publicly available
May 27, 2015
CompletedMay 27, 2015
May 1, 2015
10 months
January 12, 2012
May 8, 2015
May 8, 2015
Conditions
Keywords
Outcome Measures
Primary Outcomes (6)
Mean Photopic Monocular Distance Corrected VA (53 cm) at Day 120-180
Visual acuity (VA) was tested monocularly (each eye separately) using the manifest refraction adjusted for optical infinity and the hand-held, 100% contrast, Early Treatment Diabetic Retinopathy Study (ETDRS) chart set at 53 centimeters (cm) on the nearpoint rod. VA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the primary eye.
Day 120-180 from second eye implantation
Number of Cumulative and Persistent Adverse Events as Defined in IS EN ISO 11979-7:2006, up to Day 120-180
Cumulative and persistent adverse events were collected. This outcome measure was prespecified for the multifocal IOL.
Day 0 first operative eye visit, up to Day 120-180 from second eye implantation
Photopic Contrast Sensitivity Without Glare at Day 120-180
Contrast sensitivity (ie, the ability to detect objects by distinguishing them from their background) was assessed binocularly with the participant's best spectacle correction under photopic (bright) conditions at a distance of 8 feet at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000 without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Scores of (-1) were set to missing; hence, the mean measures may be overestimated and the variability measures may be underestimated. A higher numeric value represents better contrast sensitivity.
Day 120-180 from second eye implantation
Photopic Contrast Sensitivity With Glare at Day 120-180
Contrast sensitivity was assessed binocularly with the participant's best spectacle correction under photopic (bright) conditions at a distance of 8 feet at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000 with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Scores of (-1) were set to missing; hence, the mean measures may be overestimated and the variability measures may be underestimated. A higher numeric value represents better contrast sensitivity.
Day 120-180 from second eye implantation
Mesopic Contrast Sensitivity Without Glare at Day 120-180
Contrast sensitivity was assessed binocularly with the participant's best spectacle correction under mesopic (dim lighting) conditions at a distance of 8 feet at spatial frequencies of 1.5, 3, 6, and 12 cycles per degree (cpd) using the Vector Vision CSV 1000 without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Scores of (-1) were set to missing; hence, the mean measures may be overestimated and the variability measures may be underestimated. A higher numeric value represents better contrast sensitivity.
Day 120-180 from second eye implantation
Mesopic Contrast Sensitivity With Glare at Day 120-180
Contrast sensitivity was assessed binocularly with the participant's best spectacle correction under mesopic conditions at a distance of 8 feet at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000 with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Scores of (-1) were set to missing; hence, the mean measures may be overestimated and the variability measures may be underestimated. A higher numeric value represents better contrast sensitivity.
Day 120-180 from second eye implantation
Secondary Outcomes (4)
Mean Photopic Monocular Best Corrected Distance VA (4 m) at Day 120-180
Day 120-180 from second eye implantation
Mean Photopic Monocular Distance Corrected Near VA at Standard Distance (40 cm) at Day 120-180
Day 120-180 from second eye implantation
Overall Spectacle Independence Using SILVER Patient Reported Outcome (PRO) Questionnaire at Day 120-180
Day 120-180 from second eye implantation
Near Spectacle Independence Using SILVER Patient Reported Outcome (PRO) Questionnaire at Day 120-180
Day 120-180 from second eye implantation
Study Arms (2)
Multifocal IOL
EXPERIMENTALAcrySof® IQ ReSTOR® +2.5 D Multifocal IOL Model SN6AD2 \[SV25T0\], bilateral implantation
Monofocal IOL
ACTIVE COMPARATORAcrySof® IQ Monofocal IOL Model SN60WF, bilateral implantation
Interventions
Multifocal IOL with extended secondary focal point implanted for long-term use over the lifetime of the cataract patient
Monofocal IOL implanted for long-term use over the lifetime of the cataract patient
Eligibility Criteria
You may qualify if:
- Diagnosis of bilateral cataracts
- Willing and able to complete all required postoperative visits
- Calculated lens power within the available supply range
- Planned cataract removal by phacoemulsification
- Potential postoperative visual acuity of 0.2 logMAR or better in both eyes
- Preoperative astigmatism less than 1.0 diopter
- Clear intraocular media other than cataract in study eyes
- Preoperative Best Corrected Distance Visual Acuity (BCDVA) worse than 0.2 logMAR
- Able to undergo second eye surgery between 7 days and 30 days of the first eye surgery
You may not qualify if:
- Previous refractive surgery
- Inflammation or edema of the cornea
- Optic nerve atrophy
- Pregnancy
- Current participation in another investigational drug or device study
Contact the study team to confirm eligibility.
Sponsors & Collaborators
- Alcon Researchlead
Related Publications (1)
Williams JR, Kim HW, Crespi CM. Modeling observations with a detection limit using a truncated normal distribution with censoring. BMC Med Res Methodol. 2020 Jun 29;20(1):170. doi: 10.1186/s12874-020-01032-9.
PMID: 32600261DERIVED
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Results Point of Contact
- Title
- Magda Michna, PhD
- Organization
- Alcon Research, Ltd.
Study Officials
- STUDY DIRECTOR
Magda Michna, PhD
Alcon Research
Publication Agreements
- PI is Sponsor Employee
- No
- Restriction Type
- OTHER
- Restrictive Agreement
- Yes
Study Design
- Study Type
- interventional
- Phase
- not applicable
- Allocation
- RANDOMIZED
- Masking
- DOUBLE
- Who Masked
- PARTICIPANT, OUTCOMES ASSESSOR
- Purpose
- TREATMENT
- Intervention Model
- PARALLEL
- Sponsor Type
- INDUSTRY
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
January 12, 2012
First Posted
January 16, 2012
Study Start
February 1, 2012
Primary Completion
December 1, 2012
Study Completion
December 1, 2012
Last Updated
May 27, 2015
Results First Posted
May 27, 2015
Record last verified: 2015-05