NCT01469715

Brief Summary

The purpose of this study is to assess the accuracy of the Becton Dickenson (BD) Technologies Glucose Binding Protein-Based Continuous Glucose Monitor (GBP CGM) in patients with Type 1 diabetes during low (goal glucose 55 mg/dL), normal (80-140 mg/dL) and high (\>180mg/dL) glucose levels over a 24 hour period. This will be achieved by monitoring blood sugar levels when a regular dinner meal is given, when a liquid breakfast meal (BOOST Original containing 41 grams Carbohydrates (CHO), 4 grams fat, 10 grams protein) is given, when subcutaneous insulin is dosed to induce hypoglycemia to a goal of 55 mg/dL, and when a regular lunch meal is given. A Continuous Glucose Monitor (CGM) is an electronic device that measures and displays blood sugar (glucose) levels in the body throughout the day and night. The method being used to detect blood sugar in the investigational Glucose Binding Protein-Based Continuous Glucose Monitor (GBP CGM) is different than the method that is currently in use by commercially available models. Some sensors cannot tell the difference between glucose (sugar) and other substances such as Tylenol, aspirin or citric acid etc. Because they cannot tell the difference, they may give false readings. The GBP CGM is made to only recognize glucose in the body rather than other substances (e.g., Tylenol, aspirin, citric acid, etc.). As a result, the investigators expect the new GBP CGM to be more accurate at detecting low blood sugar levels than the current devices.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
16

participants targeted

Target at below P25 for phase_2

Timeline
Completed

Started Nov 2011

Shorter than P25 for phase_2

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

November 1, 2011

Completed
6 days until next milestone

First Submitted

Initial submission to the registry

November 7, 2011

Completed
3 days until next milestone

First Posted

Study publicly available on registry

November 10, 2011

Completed
8 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

July 1, 2012

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

July 1, 2012

Completed
3.1 years until next milestone

Results Posted

Study results publicly available

July 31, 2015

Completed
Last Updated

July 31, 2015

Status Verified

July 1, 2015

Enrollment Period

8 months

First QC Date

November 7, 2011

Results QC Date

July 3, 2015

Last Update Submit

July 3, 2015

Conditions

Keywords

Continuous Glucose Monitor

Outcome Measures

Primary Outcomes (1)

  • Absolute Relative Difference (ARD)

    ARD=100\*(G\_sensor-G\_reference)/G\_reference Calculated for when patient's G\_ref was Normal (70-180 mg/dl), Hyperglycemic (\>180 mg/dl) and Hypoglycemic (\<70 mg/dl) The study data includes 208 paired sensor-YSI plasma glucose readings (G\_reference) for each GBP CGM sensor (G\_sensor) inserted for 24 hours during hyperglycemic and hypoglycemic challenge conditions. Data pairs will permit the detailed evaluation of sensor performance parameters, including static accuracy metrics such as median and mean absolute deviations and median and mean absolute relative deviation and Point CG-EGA, as well as dynamic parameters, such as warm-up time, trend accuracy (Rate CG-EGA), and sensor lag.

    25.5 hours

Study Arms (1)

GBP-CGM

EXPERIMENTAL

All participants will wear one active GBP-CGM and one inactive GBP-CGM

Device: GBP CGM

Interventions

GBP CGMDEVICE

Visit 1: Screening visit to determine if subject qualifies for the study. Visit 2: Inpatient admission requiring a 25.5-hour hospital stay. Each subject will wear one active \& one mock device simultaneously during hyperglycemic \& hypoglycemic challenge conditions to observe a wide range of glucose values. Visit 3 \& 4: Subjects will return to the research center approximately 24 \& 48 hours after sensor removal, respectively, for evaluation of the postimplantation sensor site. Visit 5: Subjects will return to the research center approximately 28 days post inpatient admission. Blood samples for future testing of GBP and polyethylene Glycol neutralizing antibodies will be taken at Visit 1 \& 5.

Also known as: Glucose binding protein-based continuous glucose monitor
GBP-CGM

Eligibility Criteria

Age21 Years - 65 Years
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)

You may qualify if:

  • Clinical diagnosis of type 1 diabetes mellitus for ≥1 year. For an individual to be enrolled at least one criterion from each list must be met.
  • Criteria for documented hyperglycemia (at least 1 must be met):
  • Fasting glucose ≥126 mg/dL - confirmed
  • Two-hour oral Glucose Tolerance Tests (OGTT) glucose ≥200 mg/dL - confirmed
  • HbA1c ≥6.5% documented - confirmed
  • Random glucose ≥200 mg/dL with symptoms
  • No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes
  • Criteria for requiring insulin at diagnosis (1 must be met):
  • Participant required insulin at diagnosis and continually thereafter
  • Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually
  • Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with latent autoimmune diabetes in adults (LADA) and did require insulin eventually and used continually
  • Use of an insulin pump to treat his or her diabetes for at least six months prior to the study.
  • Actively using a bolus calculator function with the current insulin pump with pre-defined parameters for glucose goal(s), carbohydrate ratio(s), and insulin sensitivity factor(s).
  • Signed informed consent
  • Age ≥21 and \<65 years old
  • +2 more criteria

You may not qualify if:

  • Uncontrolled arterial hypertension (diastolic blood pressure \>90 mm Hg and/or systolic blood pressure \>160 mm Hg)
  • Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥three times the upper reference limit
  • Impaired renal function measured as creatinine \>1.2 times above the upper limit of normal
  • Diabetic ketoacidosis in the past 6 months
  • Severe hypoglycemia resulting in a seizure or loss of consciousness in the 12 months prior to enrollment
  • Conditions which may increase the risk of induced hypoglycemia such as known coronary artery disease, congestive heart failure, history of any cardiac disorder or arrhythmia, history of a cerebrovascular event, history of migraines, seizure disorder, syncope, adrenal insufficiency, or neurological disease.
  • Current use of medications containing \>4000 mg acetaminophen per day.
  • Current use of L-Monoamine oxidases (MAO) inhibitors.
  • Known microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy),such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment
  • Known allergy to eggs
  • Pregnancy, breast-feeding or intention of becoming pregnant
  • Current or recent alcohol or drug abuse by patient history.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

University of Virginia

Charlottesville, Virginia, 22908, United States

Location

MeSH Terms

Conditions

Diabetes Mellitus, Type 1

Condition Hierarchy (Ancestors)

Diabetes MellitusGlucose Metabolism DisordersMetabolic DiseasesNutritional and Metabolic DiseasesEndocrine System DiseasesAutoimmune DiseasesImmune System Diseases

Results Point of Contact

Title
Stacey Anderson, MD
Organization
University of Virginia

Study Officials

  • Stacey Anderson, MD

    University of Virginia, Center for Diabetes Technology

    PRINCIPAL INVESTIGATOR

Publication Agreements

PI is Sponsor Employee
Yes

Study Design

Study Type
interventional
Phase
phase 2
Allocation
NA
Masking
NONE
Purpose
SUPPORTIVE CARE
Intervention Model
SINGLE GROUP
Sponsor Type
OTHER
Responsible Party
PRINCIPAL INVESTIGATOR
PI Title
Assistant Professor

Study Record Dates

First Submitted

November 7, 2011

First Posted

November 10, 2011

Study Start

November 1, 2011

Primary Completion

July 1, 2012

Study Completion

July 1, 2012

Last Updated

July 31, 2015

Results First Posted

July 31, 2015

Record last verified: 2015-07

Locations