IRB-HSR# 14296 The Use of the Intrathoracic Pressure Regulator (ITPR) to Improve Systemic Blood Pressure in Patient Undergoing CABG Surgery
1 other identifier
interventional
20
1 country
1
Brief Summary
Briefly, after the induction of anesthesia and the placement of TEE, hemodynamic variables (pulmonary and systemic blood pressure, central and pulmonary venous pressure, cardiac output, calculated SVR, etc.) will be collected. In addition, left ventricular performance (including estimates of LVEDV, LVESV, EF, FAC, etc.) will be assessed using TEE. Once these baseline data are recorded, the ITPR will be inserted in the anesthesia circuit and activated to provide -9 mmHg ETP. After the ITPR has been active for at least two minutes, the same hemodynamic and TEE data obtained above will be gathered. After the data is recorded, the ITPR will be disconnected and no further interventions will be made. In addition to the hemodynamic and echocardiographic data described above, an arterial blood gas will be obtained from the pre-existing radial artery catheter during the on- and off- states. Finally, the TEE examination will be recorded on videotape or DVD. A second echocardiographer, blinded to patient and ITPR status will review each echocardiogram and assess left ventricular performance. In addition to the data derived at the time of testing, the second echocardiographer will assess, if possible, changes in EF using Simpson's method of disks is used to calculate the LV volume. This is a proof of concept/feasibility study designed to test the primary hypothesis that use of the ITPR will result in increased systemic blood pressure and cardiac output in patients undergoing CABG surgery. The effect of the ITPR on other secondary indicators of cardiac performance will also be examined. These include but are not limited to left ventricular end diastolic volume (LVEDV), ejection fraction (EF), left ventricular end systolic volume (LVESV), and fractional area change (FAC) as assessed by echocardiography, pulmonary artery pressure, and calculated systemic vascular resistance (SVR).
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at below P25 for phase_2 coronary-artery-disease
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
May 1, 2009
CompletedPrimary Completion
Last participant's last visit for primary outcome
May 1, 2010
CompletedFirst Submitted
Initial submission to the registry
September 17, 2010
CompletedFirst Posted
Study publicly available on registry
September 20, 2010
CompletedAugust 10, 2011
August 1, 2011
1 year
September 17, 2010
August 9, 2011
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
hemodynamic variables
hemodynamic variables (pulmonary and systemic blood pressure, central and pulmonary venous pressure, cardiac output, calculated SVR) will be collected at baseline \& 2 minutes post device activation
baseline & 2 minutes post device activation
Secondary Outcomes (1)
left ventricular performance
baseline &2 minutes after activation of the device
Study Arms (1)
ITPR device
EXPERIMENTALthe ITPR will be inserted in the anesthesia circuit and activated to provide -10 mmHg ETP.
Interventions
the ITPR will be inserted in the anesthesia circuit and activated to provide -10 mmHg ETP.
Eligibility Criteria
You may qualify if:
- \. patients presenting for elective CABG with planned intraoperative TEE 2. age 18 years of age and older 3. informed consent has been obtained
You may not qualify if:
- \. Patients with planned valve surgery (valve or CABG + valve) 2. patients with a contraindication to transesophageal echocardiography (TEE); including patients with extensive esophageal or gastric disease. Relative contraindications include esophageal varices, Barrett's esophagus, Zenker's diverticulum, and postradiation therapy of the esophageal area.
- \. patients requiring IABP or VAD pre-operatively 4. emergent CABG 5. pneumothorax 6. hemothorax 7. uncontrolled bleeding 8. uncontrolled hypertension defined as SBP \> 180 mmHg at the time of surgery
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
University of Virginia Health System
Charlottesville, Virginia, 22908, United States
Related Publications (8)
Lurie KG, Zielinski TM, McKnite SH, Idris AH, Yannopoulos D, Raedler CM, Sigurdsson G, Benditt DG, Voelckel WG. Treatment of hypotension in pigs with an inspiratory impedance threshold device: a feasibility study. Crit Care Med. 2004 Jul;32(7):1555-62. doi: 10.1097/01.ccm.0000131207.29081.a2.
PMID: 15241102BACKGROUNDLurie KG, Zielinski T, McKnite S, Aufderheide T, Voelckel W. Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation. 2002 Jan 1;105(1):124-9. doi: 10.1161/hc0102.101391.
PMID: 11772887BACKGROUNDLurie KG, Voelckel WG, Zielinski T, McKnite S, Lindstrom P, Peterson C, Wenzel V, Lindner KH, Samniah N, Benditt D. Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg. 2001 Sep;93(3):649-55. doi: 10.1097/00000539-200109000-00024.
PMID: 11524335BACKGROUNDLurie KG, Mulligan KA, McKnite S, Detloff B, Lindstrom P, Lindner KH. Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest. 1998 Apr;113(4):1084-90. doi: 10.1378/chest.113.4.1084.
PMID: 9554651BACKGROUNDYannopoulos D, McKnite S, Metzger A, Lurie KG. Intrathoracic pressure regulation improves 24-hour survival in a porcine model of hypovolemic shock. Anesth Analg. 2007 Jan;104(1):157-62. doi: 10.1213/01.ane.0000249047.80184.5a.
PMID: 17179262BACKGROUNDYannopoulos D, McKnite SH, Metzger A, Lurie KG. Intrathoracic pressure regulation for intracranial pressure management in normovolemic and hypovolemic pigs. Crit Care Med. 2006 Dec;34(12 Suppl):S495-500. doi: 10.1097/01.CCM.0000246082.10422.7E.
PMID: 17114984BACKGROUNDYannopoulos D, Metzger A, McKnite S, Nadkarni V, Aufderheide TP, Idris A, Dries D, Benditt DG, Lurie KG. Intrathoracic pressure regulation improves vital organ perfusion pressures in normovolemic and hypovolemic pigs. Resuscitation. 2006 Sep;70(3):445-53. doi: 10.1016/j.resuscitation.2006.02.005. Epub 2006 Aug 9.
PMID: 16901611BACKGROUNDYannopoulos D, Nadkarni VM, McKnite SH, Rao A, Kruger K, Metzger A, Benditt DG, Lurie KG. Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest. Circulation. 2005 Aug 9;112(6):803-11. doi: 10.1161/CIRCULATIONAHA.105.541508. Epub 2005 Aug 1.
PMID: 16061732BACKGROUND
MeSH Terms
Conditions
Condition Hierarchy (Ancestors)
Study Officials
- PRINCIPAL INVESTIGATOR
Edward C Nemergut, MD
University of Virginia Anesthesiology
Study Design
- Study Type
- interventional
- Phase
- phase 2
- Allocation
- NON RANDOMIZED
- Masking
- NONE
- Purpose
- HEALTH SERVICES RESEARCH
- Intervention Model
- SINGLE GROUP
- Sponsor Type
- OTHER
Study Record Dates
First Submitted
September 17, 2010
First Posted
September 20, 2010
Study Start
May 1, 2009
Primary Completion
May 1, 2010
Last Updated
August 10, 2011
Record last verified: 2011-08